文献速递关节外科

在全美大型医疗系统中,使用超多孔髋臼杯与交联聚乙烯行初次全髋关节置换术时,是否使用髋臼螺钉对假体生存率无差异

No Difference in Survivorship Following Primary Total Hip Arthroplasty Using Ultraporous Acetabular Cups and Cross-Linked Polyethylene With and Without Acetabular Screws in a Large United States Health Care System.
PubMed 文献 · J Arthroplasty · 2024-10-16

该队列研究基于美国某医疗系统全关节置换登记库,纳入2010至2021年因骨关节炎行无并发症初次全髋关节置换术、使用超多孔髋臼杯与交联聚乙烯内衬的≥18岁患者,比较使用与不使用1至2枚髋臼螺钉的翻修风险。共识别46,785例全髋关节置换术,螺钉使用率从65.3%降至49.9%。10年髋臼无菌性松动翻修风险无差异(0.2% vs 0.1%,HR 1.97,95%CI 0.84-4.59,P=0.119),总体髋臼或股骨翻修、松动或假体周围骨折风险亦无差异。

要点

  • 使用与不使用髋臼螺钉的10年髋臼松动翻修风险无差异(0.2% vs 0.1%,HR 1.97,95%CI 0.84-4.59,P=0.119)。
  • 总体髋臼或股骨翻修、松动或假体周围骨折风险在两组间无差异。
  • 螺钉使用率从65.3%降至49.9%,使用螺钉与不使用的髋臼松动翻修风险无差异。

核心结论

  • 在现代髋臼杯与内衬下,常规无并发症初次全髋关节置换术中,使用或不使用螺钉与髋臼松动翻修风险无差异,既无优势也无劣势。
  • 使用螺钉与伤害无关,但是否有额外获益仍有争议。

研究设计与样本

  • 基于美国某医疗系统全关节置换登记库的队列研究,纳入2010至2021年因骨关节炎行无并发症初次全髋关节置换术、使用超多孔髋臼杯与交联聚乙烯内衬、使用或不使用1至2枚髋臼螺钉的≥18岁患者,共46,785例全髋关节置换术。
  • 采用多变量Cox比例风险回归评估翻修风险,证据等级为III级。

主要发现

  • 10年髋臼无菌性松动翻修风险:使用螺钉组0.2% vs 不使用螺钉组0.1%(HR 1.97,95%CI 0.84-4.59,P=0.119),无差异。
  • 髋臼骨折翻修:使用螺钉组1例,不使用螺钉组3例。
  • 总体髋臼或股骨翻修、松动或假体周围骨折风险两组间无差异。
  • 常规使用螺钉者与不使用者之间髋臼侧松动无差异(0.15% vs 0.06%,HR 1.26,95%CI 0.42-3.75,P=0.683)。
  • 螺钉使用率从65.3%降至49.9%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Modern cementless acetabular cups for total hip arthroplasty (THA) typically have screw options. Historically, screws were thought to improve stability, but came at the cost of pathways for osteolysis. Modern cups and liners may have made both concerns obsolete, and the utility of screws are now contested. We sought to determine modern implant survivorship relative to screw use. METHODS: We conducted a cohort study. A US health care system's Total Joint Replacement Registry was used to identify patients ≥ 18 years who underwent uncomplicated primary THA for osteoarthritis (2010 to 2021) with an ultraporous cup and cross-linked polyethylene liner, with or without one to two acetabular screws. The primary outcome was acetabular revision for aseptic loosening. Secondary outcomes were aseptic revision for acetabular fracture and any revision for acetabular/femoral loosening and periprosthetic fracture. Multiple Cox proportional hazard regression was used to evaluate revision risk. There were 46,785 THAs identified. Screw use declined from 65.3 to 49.9%. RESULTS: No difference was observed in 10-year revision risk for acetabular loosening (0.2 versus 0.1%, hazard ratio 1.97, 95% confidence interval = 0.84 to 4.59, P = 0.119). There was one revision for acetabular fracture with and three revisions without screws. There was no difference in risk of overall acetabular or femoral revision, loosening, or periprosthetic fracture. There remained no difference in acetabular-sided loosening between routine screw users and nonusers (0.15 versus 0.06%, hazard ratio 1.26, 95% confidence interval 0.42 to 3.75, P = 0.683). CONCLUSIONS: In this study of survivorship following routine uncomplicated primary THA with modern cups and liners, screw usage patterns were associated with neither an advantage nor disadvantage - neither screw usage nor avoidance was associated with differences in acetabular loosening revision risk. Screw use was not associated with harm but remains debatable if there is an added benefit. LEVEL OF EVIDENCE: Level III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Chen F, Chan PH, Prentice HA, et al. No Difference in Survivorship Following Primary Total Hip Arthroplasty Using Ultraporous Acetabular Cups and Cross-Linked Polyethylene With and Without Acetabular Screws in a Large United States Health Care System. J Arthroplasty. 2024. PMID: 39424246. doi:10.1016/j.arth.2024.10.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。