关节内金属离子水平能否预测因机械辅助裂隙腐蚀行翻修全髋关节置换术中的不良局部组织反应?
该回顾性队列研究纳入552例患者共621个金属对聚乙烯初次全髋关节置换术,其中69例因有症状的原发失败伴血清金属离子升高行翻修术,28例有术前血清和术中滑液铬、钴样本。结果显示血清钴升高可预测不良局部组织反应(P=0.002),而滑液离子水平不能,且血清与滑液离子水平相关性差(R²=0.05)。
要点
- 血清钴升高可预测不良局部组织反应(P=0.002),滑液离子水平无预测价值。
- 血清与滑液钴铬比值相关性差(R²=0.05),滑液离子不提供额外诊断或预后价值。
- 翻修距初次置换平均5.7年(范围3.8至7.6年)。
核心结论
- 滑液离子水平与不良局部组织反应无相关性,且血清与关节内离子水平不相关,滑液水平未提供优于血清水平的诊断或预后额外价值,需进一步研究以更好理解血清与滑液离子水平及其与不良局部组织反应的关系。
研究设计与样本
- 回顾性队列研究,纳入552例患者共621个金属对聚乙烯初次全髋关节置换术,其中69例因有症状的原发失败伴血清金属离子升高行翻修全髋关节置换术,28例有术前血清和术中滑液铬、钴样本。
主要发现
- 翻修病例中40.6%有术前血清和术中滑液样本;翻修距初次置换平均5.7年(范围3.8至7.6年)。
- 滑液钴和铬平均水平分别为870.9 mcg/L(范围1.1至8,300.0)和573.5 mcg/L(范围1.3至10,000.0)。
- 血清和滑液钴铬比值平均水平分别为4.0(范围0.9至7.1)和6.4(范围0至15.1)。
- 血清钴升高可预测不良局部组织反应(P=0.002),滑液水平不能预测。
- 术前血清与滑液钴铬比值相关性差(R²=0.05)。
局限性
- 需进一步研究以更好理解血清与滑液离子水平及其与不良局部组织反应的关系。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Mechanically assisted crevice corrosion is a complication that may occur in vivo at modular metal interfaces following metal-on-polyethylene total hip arthroplasty (THA). Metal ions released in vivo may be associated with adverse local tissue reactions (ALTRs). While there is no definitive value, high serum ion levels are implicated as contributors to ALTR, and various screening levels have been recommended. The purpose of this investigation was to evaluate the relationship between synovial fluid (SF) cobalt and chromium ion levels and the risk of developing ALTR. METHODS: This was a retrospective cohort study of 552 patients who underwent 621 metal-on-polyethylene primary THAs. A total of 69 patients underwent revision THA due to symptomatic primary failure with elevated serum metal ions levels. There were 28 who had preoperative serum and intraoperative SF chromium and cobalt samples. Patient demographics, surgical, and laboratory data were collected. Descriptive statistics, Mann-Whitney U, analysis of variance tests, and linear regression analyses were performed. RESULTS: There were 40.6% of revisions that had preoperative serum and intraoperative SF samples. The mean time to revision was 5.7 (range, 3.8 to 7.6) years. Mean SF cobalt and chromium levels were 870.9mcg/L (range, 1.1 to 8,300.0) and 573.5mcg/L (range, 1.3 to 10,000.0). Mean serum and SF cobalt-chromium ratios were 4.0 (range, 0.9 to 7.1) and 6.4 (range, 0 to 15.1), respectively. Elevated serum cobalt levels were predictive of ALTR (P = 0.002), SF levels were not. Analysis of preoperative serum to SF cobalt-chromium ratios showed poor correlation (R2 = 0.05). CONCLUSIONS: There was no correlation between SF ion levels and ALTR. Also, serum and intra-articular ion levels did not correlate. The SF levels did not provide additional value over serum levels for diagnosis or prognosis of mechanically assisted crevice corrosion. Further studies are needed to better understand the relationship between serum and SF ion levels and its relationship to ALTR.
引用
- Gass HM, Goel RK, Heo K, et al. Do Intra-articular Metal Ion Levels Predict Adverse Local Tissue Reaction in Revision Total Hip Arthroplasty for Mechanically Assisted Crevice Corrosion? J Arthroplasty. 2024. PMID: 39426441. doi:10.1016/j.arth.2024.10.053
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。