当代陶瓷对陶瓷轴承全髋关节置换术中陶瓷组件骨折的发生率:跨越二十年的两家三级转诊医院回顾性研究
该回顾性研究分析了两家三级医院1997至2023年间9280例使用第三代和第四代陶瓷对陶瓷轴承的全髋关节置换术,发现因轴承骨折翻修33例(0.36%),第四代陶瓷球头骨折翻修为0例,第三代陶瓷球头为26例(0.990%),第四代陶瓷内衬为2例(0.030%),第三代陶瓷内衬为5例(0.190%)。所有陶瓷球头骨折均发生在28 mm球头。年轻年龄与陶瓷球头和内衬骨折均相关。
要点
- 9280例全髋中因陶瓷对陶瓷轴承骨折翻修33例,总体发生率0.36%。
- 第四代陶瓷球头骨折翻修0例,第三代陶瓷球头骨折翻修26例(0.990%)。
- 所有陶瓷球头骨折均发生在28 mm球头,年轻年龄与球头和内衬骨折均相关。
核心结论
- 据作者所知,这是迄今关于陶瓷对陶瓷轴承骨折的最大两中心回顾性研究,陶瓷对陶瓷轴承因骨折翻修的风险较低,与既往报告一致。
- 作者数据与近期证据相当,提示最新一代陶瓷组件可显著降低球头骨折发生率,但不能降低内衬骨折发生率。
- 年轻年龄和男性可能与陶瓷组件骨折风险增加相关。
研究设计与样本
- 回顾性研究,纳入1997年至2023年间在两家三级机构接受第三代和第四代陶瓷对陶瓷轴承全髋关节置换术的9280例髋。
- 采用Kaplan-Meier生存分析评估植入物生存率,采用逻辑回归评估植入物尺寸和患者特异性因素对翻修风险的影响。
- 证据等级为III级,治疗性研究。
主要发现
- 9280例全髋关节置换术中,因陶瓷对陶瓷轴承骨折翻修33例(0.36%)。
- 第四代陶瓷球头骨折翻修0/6654例,第三代陶瓷球头骨折翻修26/2626例(0.990%)。
- 第四代陶瓷内衬骨折翻修2/6654例(0.030%),第三代陶瓷内衬骨折翻修5/2626例(0.190%)。
- 所有陶瓷球头骨折均发生在28 mm球头。
- 年轻年龄与陶瓷球头和内衬骨折均相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Ceramic-on-ceramic (CoC) bearings have been widely used in total hip arthroplasty (THA) due to their excellent wear properties. However, ceramic component fractures remain a concern. This study aimed to report the incidence of third- and fourth-generation ceramic component fracture and identify factors that might influence this complication. METHODS: A total of 9,280 hips that underwent THA with third- and fourth-generation CoC bearings at two tertiary institutions between 1997 and 2023 were retrospectively reviewed, and the incidence and associated factors of CoC bearing fracture were determined. We performed a Kaplan-Meier survival analysis to assess implant survivorship. Logistic regression was applied to evaluate the influence of implant size and patient-specific factors on the risk of revision. RESULTS: Out of the 9,280 THA procedures, there were 33 (0.36%) revisions for CoC bearing fracture. Specifically, revisions for fracture were performed for zero out of 6,654 fourth-generation CoC heads, 26 (0.990%) of 2,626 third-generation CoC heads, two (0.030%) of 6,654 fourth-generation CoC liners, and five (0.190%) of 2,626 third-generation CoC liners. All ceramic head fractures occurred in a 28 mm head. Younger age was related to both ceramic head and liner fracture. CONCLUSIONS: To our knowledge, this is the largest two-center retrospective study on CoC bearing fractures to date. The risk of revision for fracture of CoC bearings is low, as previously reported. Our data were comparable to recent evidence suggesting that the latest generation of ceramic components can significantly decrease the incidence of head fracture but not liner fracture. Factors such as younger age and men may be associated with an increased risk of ceramic component fractures. LEVEL OF EVIDENCE: III, therapeutic.
引用
- Ko YS, Kang SY, Kim HS, et al. Incidence of Ceramic Component Fractures in Total Hip Arthroplasty Using Contemporary Ceramic-On-Ceramic Bearings: A Retrospective Study Spanning Two Decades From Two Tertiary Referral Hospitals. J Arthroplasty. 2024. PMID: 39424238. doi:10.1016/j.arth.2024.10.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。