感染性膝关节置换与人工假体分期翻修
单中心回顾性分析94例感染性膝关节假体第一阶段翻修患者,采用静态抗生素骨水泥间隔器。35/94例(37.2%)发生间隔器相关并发症,其中机械失败占74.3%,感染复发占25.7%。间隔器总髓内长度小于中央骨缺损长度两倍者机械失败风险显著增加。
要点
- 静态抗生素骨水泥间隔器失败率37.2%,远高于预期
- 间隔器总髓内长度小于骨缺损长度两倍时内部失败风险显著增加(p=0.009)
- 有间隔器并发症者二期翻修时间显著延长(227天 vs 157天,p=0.014)
核心结论
- 静态抗生素骨水泥间隔器的失败率远高于预期,间隔器并发症显著延长二期翻修时间,间隔器尺寸小于节段性缺损两倍或残余骨内增强不足时机械失败风险显著增加,这些发现可作为术者避免静态间隔器机械并发症的指导。
研究设计与样本
- 回顾性分析2007年9月至2020年1月单中心94例感染性膝关节假体第一阶段翻修患者,使用X线片和临床记录评估静态间隔器失败的发生率和原因。
主要发现
- 35/94例(37.2%)发生间隔器相关并发症,其中26/35(74.3%)为间隔器构造机械失败,9/35(25.7%)为感染复发。
- 内部失败的危险因素包括间隔器总髓内长度小于中央骨缺损长度两倍(p=0.009)、近端或远端骨内间隔器接触<10%、以及胫骨结节截骨术后(p=0.005)。
- 无并发症者二期翻修平均时间157天(42至458天),有并发症者227天(11至528天),差异显著(p=0.014)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context. METHODS: A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties. RESULTS: A total of 35/94 patients (37.2%) had spacer-related complications, of which 26/35 complications (74.3%) were because of mechanical failure of the spacer construct, while 9/35 (25.7%) were due to recurrence of infection. Risk factors for internal failure were a construct where the total intramedullary spacer length was less than twice the length of the central osseous defect (p = 0.009), where proximal or distal intraosseous spacer contact was < 10%, and after tibial tubercle osteotomy (p = 0.005). The incidence of spacer complications significantly increased the time to second stage: mean 157 days (42 to 458) in those without complications versus 227 days (11 to 528) with complications (p = 0.014). CONCLUSION: The failure rate of static antibiotic-loaded cement spacers is much higher than anticipated. Complications of the spacer significantly increased the time to second-stage revision. The risk of mechanical failure is significantly increased if the spacer is less than double the size of the segmental defect, or if inadequate reinforcement is inserted into the residual bone. These findings serve as a guide for surgeons to avoid mechanical complications with static spacers.
引用
- Lodge CJ, Adlan A, Nandra RS, et al. Staged revision of the infected knee arthroplasty and endoprosthesis. Bone Joint J. 2024. PMID: 39348917. doi:10.1302/0301-620X.106B10.BJJ-2023-0432.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。