文献速递脊柱外科骨质疏松与代谢性骨病

脊柱门诊中常规计算机断层扫描无体模校准用于机会性骨质疏松筛查的准确性

Accuracy of Phantomless Calibration of Routine Computed Tomography Scans for Opportunistic Osteoporosis Screening in the Spine Clinic.
PubMed 文献 · Spine (Phila Pa 1976) · 2024-06-26

本研究为诊断准确性研究,纳入45例拟行腰椎手术且术前有CT和6个月内DXA的患者,比较四种参考组织组合无体模校准CT所得体积骨密度与未校准Hounsfield单位诊断低骨密度的准确性。脂肪与竖脊肌组合以162 mg/cm³为阈值检测低骨密度的敏感性为90%(AUC=0.671)。

要点

  • 脂肪与竖脊肌组合校准CT,阈值162 mg/cm³检测低骨密度敏感性90%(AUC=0.671)。
  • 校准后体积骨密度与DXA T值的相关性优于未校准Hounsfield单位,L2相关系数最高。
  • 该方法无需体模,可在门诊对常规术前CT进行简单校准。

核心结论

  • 该新方法无需体模即可在门诊对常规术前CT进行简单校准,作者提出脂肪与竖脊肌组合以162 mg/cm³为阈值用于低骨密度筛查,敏感性高(90%)。

研究设计与样本

  • 诊断准确性研究,纳入拟行腰椎手术、术前有CT扫描且6个月内行双能X线吸收法(DXA)扫描的患者45例(男/女=10/35,平均年龄63.3岁)。

主要发现

  • 校准后体积骨密度与DXA T值的相关性优于Hounsfield单位,其中L2的相关系数最高。
  • 采用脂肪与竖脊肌校准、阈值162 mg/cm³检测低骨密度的敏感性为90%(AUC=0.671)。

关键数值与推荐

  • 脂肪与竖脊肌组合校准所得体积骨密度阈值162 mg/cm³检测低骨密度:敏感性90%,AUC=0.671。

临床怎么用

  • 作者提出脂肪与竖脊肌组合以162 mg/cm³为阈值可用于低骨密度筛查,敏感性高(90%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Diagnostic accuracy study. OBJECTIVE: To establish a simple method of phantomless bone mineral density (BMD) measurement by using preoperative lumbar computed tomography (CT) scans, and compare the accuracy of reference tissue combinations to diagnose low BMD against uncalibrated Hounsfield units (HUs). SUMMARY OF BACKGROUND DATA: HUs are used as a measure of BMD; however, associations between HU and T-scores vary widely. Quantitative CT (qCT) scans are more accurate, but they require density calibration with an object of known density (phantom), which limits feasibility. As an emerging technique, phantomless (internal) calibration of routine CT scans may provide a good opportunity for screening. MATERIALS AND METHODS: Patients who were scheduled to undergo lumbar surgery, with a preoperative CT scan, and a dual-energy x-ray absorptiometry (DXA) scan within six months were included. Four tissues were selected for calibration: subcutaneous adipose (A), erector spinae (ES), psoas (P), and aortic blood (AB). The HUs of these tissues were used in linear regression against ground-truth values. Calibrations were performed by using two different internal tissues at a time to maintain simplicity and in-office applicability.Volumetric bone mineral densities (vBMD) derived from internally calibrated CT scans were analyzed for new threshold values for low bone density. Areas under the curve (AUC) were calculated with 95% CI. RESULTS: Forty-five patients were included (M/F=10/35, mean age: 63.3). Calibrated vBMDs had stronger correlations with DXA T -scores when compared with HUs, with L2 exhibiting the highest coefficients. Calibration by using A and ES with the threshold of 162 mg/cm 3 had a sensitivity of 90% in detecting low BMD (AUC=0.671). CONCLUSIONS: This novel method allows simple, in-office calibration of routine preoperative CT scans without the use of a phantom. Calibration using adipose and erector spinae with a threshold of 162 mg/cm 3 is proposed for low bone density screening with high sensitivity (90%). LEVEL OF EVIDENCE: Level III.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Cetik RM, Crawford CH, Glassman SD, et al. Accuracy of Phantomless Calibration of Routine Computed Tomography Scans for Opportunistic Osteoporosis Screening in the Spine Clinic. Spine (Phila Pa 1976). 2024. PMID: 38919066. doi:10.1097/BRS.0000000000005080

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。