文献速递脊柱外科骨质疏松与代谢性骨病

机会性利用腰椎计算机断层扫描和磁共振成像进行骨质疏松筛查

Opportunistic use of lumbar computed tomography and magnetic resonance imaging for osteoporosis screening.
PubMed 文献 · Osteoporos Int · 2024-06-28

本研究回顾性评估109例接受腰椎定量CT和MRI的腰椎手术患者,比较基于CT的Hounsfield单位(HU)值和基于MRI的椎体骨质量(VBQ)评分对骨质疏松(OP)的诊断性能。结果显示OP组HU值显著更低、VBQ评分显著更高,两者诊断OP的曲线下面积分别为0.959和0.880,最佳阈值分别为HU值<97.06和VBQ评分>3.08。

要点

  • 与健康患者相比,骨质疏松患者HU值更低、VBQ评分更高。
  • HU值和VBQ评分均可简单区分骨质疏松患者,阈值分别为HU值<97.06和VBQ评分>3.08。
  • 机会性使用CT和MRI有望成为T值筛查骨质疏松的潜在替代方法。

核心结论

  • 机会性使用CT和MRI可以简单区分骨质疏松患者,有望成为骨质疏松筛查中T值的潜在替代方法。

研究设计与样本

  • 回顾性评估109例接受腰椎定量CT(QCT)和MRI的腰椎手术患者,计算基于CT的HU值和基于MRI的VBQ评分,并根据QCT结果构建受试者工作特征(ROC)曲线以确定诊断性能。

主要发现

  • 骨质疏松组HU值显著低于健康组,VBQ评分显著高于健康组。
  • HU值和VBQ评分诊断骨质疏松的曲线下面积分别为0.959和0.880。
  • 以最佳灵敏度和特异度确定的诊断阈值分别为HU值97.06和VBQ评分3.08。

关键数值与推荐

  • HU值<97.06和VBQ评分>3.08可区分骨质疏松患者。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: Compared with the healthy patients, patients with osteoporosis had a lower Hounsfield unit (HU) value and a higher vertebral bone quality (VBQ) score. Both the HU value and VBQ score can simply distinguish patients with osteoporosis (OP), with a cutoff value of HU value < 97.06 and VBQ score > 3.08. INTRODUCTION: The purpose of this study is to determine whether the opportunistic use of computed tomography (CT) or magnetic resonance imaging (MRI) is effective for identifying spine surgical patients with OP. METHODS: We retrospectively evaluated 109 lumbar spine surgery patients who received lumbar quantitative CT (QCT) and MRI. Using the area under the curve, the CT-based HU value and MRI-based VBQ score were calculated. Then, based on the QCT results, receiver operating characteristic (ROC) curves were constructed to determine the diagnostic performance of the HU value and VBQ score. RESULTS: The HU value was significantly lower in the OP group, and the VBQ score was significantly higher in the OP group. Using the area under the curve, the diagnostic performance of the HU value and VBQ score for OP were 0.959 and 0.880, respectively. The diagnostic threshold values determined with optimal sensitivity and specificity were an HU value of 97.06 and a VBQ score of 3.08. CONCLUSION: Opportunistic use of CT and MRI can simply distinguish patients with OP, which are expected to be potential alternatives to T-score for the osteoporosis screening.

来源:Osteoporos Int,查看原文。版权归原作者所有。

引用

  1. Pu X, Liu B, Wang D, et al. Opportunistic use of lumbar computed tomography and magnetic resonance imaging for osteoporosis screening. Osteoporos Int. 2024. PMID: 38942897. doi:10.1007/s00198-024-07164-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。