商用冲洗液去除多孔钛植入物表面金黄色葡萄球菌及生物膜的体外疗效研究
本研究比较五种冲洗液对感染金黄色葡萄球菌的三维多孔钛盘(孔径400、700、1000μm)的体外杀菌效果,急性感染孵育3小时、慢性生物膜感染孵育3天。生理盐水冲洗无效;溶液#3和#4可减少急性感染细菌,但仅#4对生物膜有效;400μm孔径残留细菌最多。
要点
- 生理盐水及溶液#1、#2冲洗未能减少多孔钛盘细菌负荷。
- 溶液#3和#4可减少急性感染细菌,仅#4对生物膜有效。
- 400μm孔径钛盘冲洗后残留细菌更多,提示小孔径细菌难以清除。
核心结论
- 生理盐水、溶液#1和#2冲洗感染多孔钛盘未能减少细菌负荷。
- 溶液#3和#4可减少急性感染细菌,但仅#4对生物膜显示出优于生理盐水的清除效果。
- 400μm孔径钛盘冲洗后残留细菌更多,提示小孔径细菌清除困难。
研究设计与样本
- 体外研究:将三维打印多孔钛盘(2×4mm,孔径400、700、1000μm)感染金黄色葡萄球菌(1×10^6 CFU/mL),孵育3小时或3天分别形成急性感染或生物膜。
- 冲洗液包括生理盐水、抗生素溶液和消毒剂溶液,冲洗后反复超声处理,超声液培养定量细菌,扫描电镜观察生物膜。
- 统计分析采用单因素方差分析(ANOVA)及Tukey-Kramer事后检验,P<.05为显著。
主要发现
- 急性感染400μm孔径组:生理盐水与溶液#3比较P=.015,生理盐水与溶液#4比较P=.015。
- 溶液#4在所有孔径中细菌计数最低;生物膜中,溶液#4在400μm孔径残留浓度低于生理盐水(P=.06)和溶液#2(P=.039)。
- 扫描电镜显示溶液#4冲洗样本生物膜减少。
临床怎么用
- 作者认为,在处理存在多孔组件及潜在生物膜的假体周围关节感染时,应考虑这些结果。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Periprosthetic joint infection remains a major problem. The bactericidal efficacy of commercial irrigation solutions for the treatment of infection is not well established in the presence of porous titanium (Ti) implants. This study compared the in vitro efficacy of five irrigation solutions on infected three-dimensional-printed porous Ti discs. METHODS: Titanium discs (2 × 4 mm, 400, 700, and 1,000 μm) were infected with S. aureus (1 × 106 colony-forming unit/mL) and incubated for 3 hours or 3 days to create acute or chronic infection with biofilm. Discs were irrigated with saline, antibiotic, or antiseptic solutions, then repeatedly sonicated. Sonicates were cultured for bacterial quantification. Statistical analyses were performed using one-way analysis of variance (ANOVA), followed by Tukey-Kramer post hoc testing (P < .05 significance). Biofilms were visualized by scanning electron microscopy. RESULTS: Saline irrigation was ineffective in both groups. In acute infections with 400 μm pores, differences were found with saline versus solution #3 (P = .015) and #4 (P = .015). Solution #4 had the lowest bacterial counts for all pore sizes. For biofilm, irrigation with saline, solutions #1, #2, and #3 inadequately cleared bacteria in all pore sizes. Lower remaining concentrations were observed in #4 with 400μm pores compared to saline (P = .06) and #2 (P = .039). The scanning electron microscopy showed a reduction of biofilm in samples washed with #4. CONCLUSIONS: Irrigation of infected porous Ti discs with saline, solutions #1 and #2 failed to reduce the bacterial load. The 400 μm discs consistently had more bacteria despite irrigation, highlighting the difficulty of removing bacteria from small pores. Solutions #3 and #4 reduced bacteria acutely, but only #4 demonstrated efficacy in clearing biofilm compared to saline. These results should be considered when treating periprosthetic joint infection in the presence of porous components and the potential presence of biofilm.
引用
- Seta JF, Pawlitz PR, Aboona F, et al. Efficacy of Commercially Available Irrigation Solutions on Removal of Staphylococcus Aureus and Biofilm From Porous Titanium Implants: An In Vitro Study. J Arthroplasty. 2024. PMID: 38889807. doi:10.1016/j.arth.2024.06.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。