双杯结构治疗Paprosky 3A与3B型髋臼缺损平均39个月随访的结局
该回顾性研究比较双杯结构(DC组,n=48)与多孔钽假体组件联合增强块(PT组,n=48)重建Paprosky III型髋臼缺损的疗效,两组临床评分无显著差异,但DC组在Paprosky 3B型缺损中旋转中心更接近解剖位置、术后下肢不等长更小,以无菌性松动为终点的累积生存率DC组优于PT组。
要点
- 两组Harris髋关节评分(P=.786)、牛津髋关节评分(P=.570)和36项简表调查(P=.691)无显著差异。
- Paprosky 3B型缺损中,DC组重建旋转中心垂直距离2.630 mm vs PT组7.355 mm(P=.0034),水平距离1.881 mm vs -6.413 mm(P<.0001)。
- 以无菌性松动再翻修为终点,DC组累积生存率100%(95%CI 100)优于PT组83.4%(95%CI 70.5至98.6),P=.046。
核心结论
- 作者认为双杯结构是重建Paprosky III型骨缺损的可靠翻修技术。
- 作者指出尽管脱位仍具挑战性,但该技术实现的生物力学上更优的恢复降低了无菌性松动的风险。
研究设计与样本
- 回顾性综述,比较双杯结构组(DC组,n=48)与多孔钽外壳联合增强块组(PT组,n=48)。
- 所有手术于2017年至2022年在同一机构完成。
- 临床结局评估采用Harris髋关节评分、牛津髋关节评分和36项简表调查。
- 影像学评估测量术前及术后髋关节旋转中心位置和下肢不等长。
- 随访期间监测术后并发症和假体生存率。
主要发现
- 两组临床结局均大幅改善,Harris髋关节评分(P=.786)、牛津髋关节评分(P=.570)和36项简表调查(P=.691)无显著差异。
- Paprosky 3B型缺损中,DC组重建旋转中心垂直距离2.630 mm vs PT组7.355 mm(P=.0034),水平距离1.881 mm vs -6.413 mm(P<.0001),DC组更接近解剖旋转中心。
- DC组术后下肢不等长-8.252 mm vs PT组-1.821 mm(P=.0008),DC组更小。
- DC组主要并发症为脱位,仅1例患者因反复脱位接受再翻修。
- 以无菌性松动再翻修为终点,DC组累积生存率100%(95%CI 100)优于PT组83.4%(95%CI 70.5至98.6),P=.046。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Modular reconstruction systems based on porous tantalum (PT) prosthetic components have been increasingly used for the treatment of complex acetabular bone defects in revision total hip arthroplasty. We report a novel technique that applies a revision cup as a "super-augment" to form a "double-cup" construct for Paprosky type III defects. METHODS: A retrospective review was conducted on revision total hip arthroplasty cases, comparing those treated with double-cup constructs (DC group, n = 48) to those treated with PT shells and augments (PT group, n = 48). All procedures were performed at the same institute between 2017 and 2022. Clinical outcome evaluation utilized the Harris Hip Score, Oxford Hip Score, and the 36-Item Short Form Survey. Preoperative and postoperative radiographic assessments measured hip center of rotation (COR) position and leg length discrepancy. Additionally, postoperative complications and implant survivorship were monitored during the follow-up period. RESULTS: The clinical outcomes improved substantially in both groups, which showed no significant difference in the Harris Hip Score (P = .786), the Oxford Hip Score (P = .570), and the 36-Item Short Form Survey (P = .691). Compared to the PT group, the reconstruction COR was significantly closer to the anatomic COR (vertical distance: 2.630 versus 7.355 mm, P = .0034; horizontal distance: 1.881 versus -6.413 mm, P < .0001) in Paprosky 3B type defects. Additionally, postoperative leg length discrepancy was less in the DC group (-8.252 versus -1.821 mm, P = .0008). Dislocation was the main complication in the DC group, and only 1 patient received re-revision due to repeated dislocation. The cumulative survival rate of the DC group (100%; 95% confidence interval 100) was better than the PT group (83.4%; 95% confidence interval 70.5 to 98.6) when re-revisions for aseptic loosening were the endpoint (P = .046). CONCLUSIONS: The DC is a reliable revision technique for the reconstruction of Paprosky type III bone defects. Although dislocation remains challenging, the biomechanically superior restoration achieved by this technique lowers the risk of aseptic loosening.
引用
- Liu Q, Zhang RW, Ma RX, et al. Outcomes of a Double-Cup Construct to Treat Paprosky 3A and 3B Acetabular Defects at a Mean of 39 Months. J Arthroplasty. 2024. PMID: 38823520. doi:10.1016/j.arth.2024.05.070
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。