抗生素硫酸钙珠降低小鼠假体周围关节感染模型的细菌负荷并预防感染

Antibiotic calcium sulphate beads lower the bacterial burden and prevent infection in a mouse model of periprosthetic joint infection.
PubMed 文献 · Bone Joint J · 2024-06-01

该体内研究在小鼠膝关节假体周围感染(PJI)模型中比较万古霉素粉末与万古霉素缓释硫酸钙珠预防延迟接种所致PJI的疗效。结果显示,万古霉素珠组在POD 8和POD 10的体内生物发光显著低于其他组,POD 21时软组织及植入物细菌负荷较对照和万古霉素粉末组显著降低,联合软组织与植入物感染预防率在万古霉素珠组为53%。

要点

  • 万古霉素珠组POD 8和POD 10体内生物发光显著低于其他组。
  • POD 21万古霉素珠组软组织CFU较万古霉素粉末组降低1.3-log10(95%),较感染对照组降低1.5-log10(97%)。
  • 万古霉素珠组联合软组织与植入物感染预防率为53%(10/19),高于万古霉素粉末组的24%(5/21)。

核心结论

  • 在该体内小鼠模型中,释放抗生素的硫酸钙珠在降低细菌负荷和预防软组织及植入物感染方面似乎优于单用万古霉素粉末。

研究设计与样本

  • 小鼠膝关节PJI模型的体内研究。
  • 小鼠随机分为5组:无菌对照(SC,n=6)、感染对照(IC,n=15)、全身万古霉素(SV,n=9)、万古霉素粉末(VP,n=21)、万古霉素珠(VB,n=19)。
  • 手术当日(POD 0)进行干预,POD 7关节切开时接种1×10^5 CFU的生物发光金黄色葡萄球菌,POD 21处死所有小鼠。

主要发现

  • VB组POD 8和POD 10的平均体内生物发光显著低于其他组。
  • POD 21时VB组平均软组织CFU为3.6×10^3,VP组为7.0×10^4,IC组为1.0×10^5;VB较VP降低1.3-log10(95%)(p=0.022),VB较IC降低1.5-log10(97%)(p=0.007)。
  • POD 21时VB组平均植入物CFU为1.3×10^0,IC组为4.7×10^1;VB较IC降低1.6-log10(98%)(p=0.038)。
  • 联合软组织与植入物感染预防率:VB组10/19(53%),VP组5/21(24%),IC组3/15(20%),SV组0%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Delayed postoperative inoculation of orthopaedic implants with persistent wound drainage or bacterial seeding of a haematoma can result in periprosthetic joint infection (PJI). The aim of this in vivo study was to compare the efficacy of vancomycin powder with vancomycin-eluting calcium sulphate beads in preventing PJI due to delayed inoculation. METHODS: A mouse model of PJI of the knee was used. Mice were randomized into groups with intervention at the time of surgery (postoperative day (POD) 0): a sterile control (SC; n = 6); infected control (IC; n = 15); systemic vancomycin (SV; n = 9); vancomycin powder (VP; n = 21); and vancomycin bead (VB; n = 19) groups. Delayed inoculation was introduced during an arthrotomy on POD 7 with 1 × 105 colony-forming units (CFUs) of a bioluminescent strain of Staphylococcus aureus. The bacterial burden was monitored using bioluminescence in vivo. All mice were killed on POD 21. Implants and soft-tissue were harvested and sonicated for analysis of the CFUs. RESULTS: The mean in vivo bioluminescence in the VB group was significantly lower on POD 8 and POD 10 compared with the other groups. There was a significant 1.3-log10 (95%) and 1.5-log10 (97%) reduction in mean soft-tissue CFUs in the VB group compared with the VP and IC groups (3.6 × 103 vs 7.0 × 104; p = 0.022; 3.6 × 103 vs 1.0 × 105; p = 0.007, respectively) at POD 21. There was a significant 1.6-log10 (98%) reduction in mean implant CFUs in the VB group compared with the IC group (1.3 × 100 vs 4.7 × 101, respectively; p = 0.038). Combined soft-tissue and implant infection was prevented in 10 of 19 mice (53%) in the VB group as opposed to 5 of 21 (24%) in the VP group, 3 of 15 (20%) in the IC group, and 0% in the SV group. CONCLUSION: In our in vivo mouse model, antibiotic-releasing calcium sulphate beads appeared to outperform vancomycin powder alone in lowering the bacterial burden and preventing soft-tissue and implant infections.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Hart CM, Kelley BV, Mamouei Z, et al. Antibiotic calcium sulphate beads lower the bacterial burden and prevent infection in a mouse model of periprosthetic joint infection. Bone Joint J. 2024. PMID: 38821510. doi:10.1302/0301-620X.106B6.BJJ-2023-1175.R1