文献速递关节外科

多孔金属增强块与其他构架在严重髋臼骨缺损中期随访中结局相当

Porous Metal Augments Have Comparable Outcomes to Other Constructs for Severe Acetabular Bone Loss at Mid-Term Follow-up.
PubMed 文献 · J Arthroplasty · 2024-06-04

回顾性连续纳入180例Paprosky 3A或3B髋臼缺损行翻修全髋关节置换术患者,多孔金属增强块组141例与杯笼或三翼假体组39例比较,平均随访6.6±3.4年,两组髋臼构架生存率、无任何翻修生存率、脱位率和假体周围感染率均无显著差异。

要点

  • 多孔金属增强块与杯笼或三翼假体在严重髋臼骨缺损翻修中中期生存率相当。
  • 骨盆不连续亚组(n=47)两组无任何翻修生存率亦无显著差异。
  • 不稳定和感染仍是该患者人群失败的主要原因,需长期随访。

核心结论

  • 多孔金属增强块在严重髋臼骨缺损中中期(平均随访6.6年)显示出优异的生存率,即使骨盆不连续病例,结局与杯笼和三翼假体相当。

研究设计与样本

  • 回顾性连续系列研究,纳入180例Paprosky 3A或3B髋臼缺损行翻修全髋关节置换术患者,多孔金属增强块组141例,杯笼或三翼假体组39例。

主要发现

  • 髋臼假体生存率多孔金属增强块组92.2% vs 杯笼或三翼假体组87.2%,P=0.470,平均随访6.6±3.4年。
  • 无任何翻修手术生存率两组分别为78.7% vs 79.5%,P=0.720。
  • 脱位率多孔金属增强块组5.7% vs 杯笼或三翼假体组10.3%,P=0.309;假体周围感染率两组分别为7.8% vs 10.3%,P=0.623。
  • 骨盆不连续亚组(n=47)无任何翻修手术生存率两组分别为79.5% vs 72.2%,P=0.543。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Acetabular reconstruction options in the setting of severe bone loss remain limited, with few comparative studies published to date. The purpose of this study was to compare the outcomes of revision total hip arthroplasty (THA) for severe bone loss using porous metal augments to cup cage and triflange prostheses. METHODS: We reviewed a consecutive series of 180 patients who had Paprosky 3A or 3B acetabular defects and underwent revision THA. Patients treated with porous augments (n = 141) were compared with those who received cup cages or triflange constructs (n = 39). Failure of the acetabular construct was defined as undergoing acetabular revision surgery or radiographic evidence of loosening. RESULTS: There was no difference in acetabular component survivorship in patients undergoing revision THA with porous augments or a cage or triflange prosthesis (92.2 versus 87.2%, P = .470) at a mean follow-up of 6.6 ± 3.4 years. Overall, survivorship free from any revision surgery was comparable between the 2 groups (78.7 versus 79.5%, P = .720). There was also no difference in dislocation (5.7 versus 10.3%, P = .309) or periprosthetic joint infection rates (7.8 versus 10.3%, P = .623). In a subgroup analysis of patients who had pelvic discontinuity (n = 47), survivorship free from any revision surgery was comparable between the 2 groups (79.5 versus 72.2%, P = .543). CONCLUSIONS: Porous metal augments in the setting of severe acetabular bone loss demonstrated excellent survivorship at intermediate-term (mean 6.6 years follow-up, even in cases of pelvic discontinuity, with comparable outcomes to cup cages and triflanges. Instability and infection remain major causes of failure in this patient population, and long-term follow-up is needed.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tarabichi S, Baker CM, Lizcano JD, et al. Porous Metal Augments Have Comparable Outcomes to Other Constructs for Severe Acetabular Bone Loss at Mid-Term Follow-up. J Arthroplasty. 2024. PMID: 38844248. doi:10.1016/j.arth.2024.05.089

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。