这项前瞻性多中心连续队列研究纳入500例无机器人或导航辅助初次全髋关节置换术患者,分析冠状面几何重建能力及其与患者报告结局的关系。结果显示,当整体偏心距和腿长差异均在2.5 mm以内时ΔOHS最佳(P<.01),但仅10%达到该重建;在±10 mm范围内,髋臼偏心距和股骨偏心距均在±5 mm内者ΔOHS优于通过增大股骨偏心距代偿髋臼偏心距减小者(P=.040)。

要点

  • 整体偏心距和腿长差异均在0±2.5 mm内时ΔOHS最佳(P<.01),但仅10%患者达到该重建。
  • 在整体偏心距和腿长差异±10 mm内,髋臼偏心距和股骨偏心距均在±5 mm内者ΔOHS优于股骨偏心距>5 mm代偿髋臼偏心距减小者(P=.040)。
  • 维持髋臼偏心距很重要,通过增大股骨偏心距代偿与较差的牛津髋关节评分相关。

核心结论

  • 患者报告结局与生物力学重建相关,整体偏心距和腿长差异均在2.5 mm以内时预期临床改善最佳。
  • 维持髋臼偏心距很重要,通过增大股骨偏心距代偿髋臼偏心距减小与较差的牛津髋关节评分相关。

研究设计与样本

  • 前瞻性、多中心、连续队列研究,纳入500例接受无机器人或导航辅助初次全髋关节置换术的患者。

主要发现

  • 在手术髋中,平均股骨偏心距增加3±6 mm(范围-16至27),髋臼偏心距减少2±4 mm(范围-17至10)。
  • ±2.5 mm区域的等值线图显示,整体偏心距和腿长以0±2.5 mm为中心时结局最佳(ΔOHS>25,P<.01),但仅10%达到该重建。
  • 当整体偏心距和腿长差异在±10 mm内时,髋臼偏心距和股骨偏心距均在±5 mm内者ΔOHS(均值24±10,范围-5至40)优于股骨偏心距>5 mm代偿髋臼偏心距减小者(均值22±11,范围-10至46,P=.040)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Accurate hip reconstruction is associated with improved biomechanical behavior following total hip arthroplasty (THA). However, whether this is associated with improved patient-reported outcomes (PROs) is unknown. HYPOTHESIS/PURPOSE: This study aimed to: 1) describe the ability to reconstruct coronal geometry during THA without advanced technology; 2) assess whether restoration of global offset (GO) and leg length (LL) is associated with improved PROs; and 3) investigate whether increased femoral offset (FO) to compensate for reduced acetabular offset (AO) influences PROs. METHOD: This was a prospective, multicenter, consecutive cohort study of 500 patients treated with primary THA without robotics or navigation. The Oxford Hip score (OHS) was obtained preoperatively and at 1-year follow-up. Supine anteroposterior pelvic radiographs were analyzed to determine AO, FO, GO, and LL relative to the native contralateral side. Contour plots for ΔOHS based on ΔLL and ΔGO were created, and ΔOHS was calculated within and outside various ranges (±2.5, ±5, or ±10 mm). RESULTS: In the operated hip, mean FO increased by 3 ± 6 mm (range, -16 to 27), while AO decreased by 2 ± 4 mm (range, -17 to 10). The contour graph for ±2.5 mm zones showed the best outcomes (ΔOHS >25) with GO and LL centered on 0 ± 2.5 mm (P < .01). However, only 10% achieved such reconstruction. When GO and LL differences were within ±10 mm, ΔOHS was superior when both AO and FO were within ±5 mm (mean: 24 ± 10; range, -5 to 40) compared with when FO was above 5 mm to compensate for a reduction in AO (mean: 22 ± 11; range, -10 to 46; P = .040). CONCLUSIONS: The PROs were associated with biomechanical reconstruction, and the best clinical improvement can be expected when GO and LL differences are both within 2.5 mm. Maintenance of AO is important, as compensation by increasing FO is associated with inferior OHS.