极轴角减小与全髋关节置换术后不稳相关:侧坐位X线片上评估功能组件位置的新方法

Decreased "Polar Axis Angle" is Associated With Instability After Total Hip Arthroplasty: A New Method to Assess Functional Component Position on Lateral-Seated Radiographs.
PubMed 文献 · J Arthroplasty · 2024-06-21

本研究比较全髋关节置换术后脱位患者与匹配对照组的极轴角(PAA),发现脱位组侧坐位颈角(23° vs 33°,P < .001)和PAA(74° vs 83°,P = .012)显著低于对照组,站立与坐位间极轴和颈角变化也有显著差异(均P < .001),坐位PAA降低更多由功能性股骨前倾减小驱动。

要点

  • 脱位组侧坐位颈角显著低于对照组(23° vs 33°,P < .001)。
  • 脱位组侧坐位PAA显著低于对照组(74° vs 83°,P = .012)。
  • 坐位PAA降低更多由功能性股骨前倾减小驱动,强调功能性股骨版本对稳定的作用。

核心结论

  • 按年龄、性别、体重指数和髋-脊柱分类匹配后,术后发生不稳的患者侧坐位X线片上的PAA显著更低。
  • 坐位PAA降低更多由功能性股骨前倾减小驱动,强调功能性股骨版本对全髋关节置换术后稳定性的作用。

研究设计与样本

  • 回顾机构数据库,纳入初次全髋关节置换术后发生脱位且有术后全长站立位和侧坐位X线片的患者为脱位组。
  • 非脱位对照组按年龄、体重指数、性别和髋-脊柱分类以2:1匹配。
  • 由2名独立盲法培训的评估者进行颈角、髋臼前倾角和PAA的影像学测量。

主要发现

  • 脱位组(n = 37)侧坐位颈角显著低于对照组(n = 74)(23° vs 33°,P < .001)。
  • 脱位组侧坐位PAA显著低于对照组(74° vs 83°,P = .012)。
  • 站立位与坐位之间极轴和颈角的变化差异均有统计学意义(P < .001和P < .001)。
  • 脱位组内活动脊柱与僵硬脊柱患者比较,髋臼、颈或PAA均无差异。
  • 颈角对PAA的影响在各队列间呈线性趋势。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Research on hip instability has focused on establishing "safe" ranges of combined component position in supine posture or functional placement of the acetabular component based on the hip-spine relationship. A new angle, the polar axis angle (PAA), of the total hip arthroplasty (THA) components describes the concentricity of both components and can be evaluated in functional positions that confer a greater risk of instability (ie, sitting). The goal of this study was to compare the PAA in functional positions between patients who experienced a postoperative dislocation and a matched control group who did not have a dislocation. METHODS: An institutional database was searched for patients experiencing a dislocation after primary THA. Patients who had postoperative full-length standing and lateral-seatedradiographs were included in the dislocator group. A control group of nondislocator patients was matched 2:1 by age, body mass index, sex, and hip-spine classification. Radiographic measurements of the neck angle, acetabular ante-inclination, and PAA were performed by 2 separate blinded, trained reviewers. RESULTS: The lateral-seated neck angle and lateral-seated PAA measurements were significantly lower in the dislocator groups (n = 37) than the control group (n = 74) (23 versus 33 degrees, P < .001; 74 versus 83 degrees, P = .012, respectively). Significant differences were also observed in changes in the polar axes and neck angles between standing and seated positions (P < .001 and P < .001, respectively). When comparing patients who have mobile spines versus stiff spines within the dislocator group, there were no differences in the acetabular, neck, or PAAs. The effect of neck angle on the PAA showed a linear trend across cohorts. CONCLUSIONS: Patients who experience postoperative instability have a significantly lower PAA on lateral-seated radiographs when matched for age, sex, body mass index, and hip-spine classification. In addition, the lower seated PAA is driven more strongly by decreased functional femoral anteversion, which emphasizes the role of functional femoral version on stability in THA.