全膝关节置换术后下楼梯时的肌肉活动与生物力学:后稳定型与内侧球窝型设计的比较研究
28例全膝关节置换患者随机接受内侧球窝型(MBS,n=14)或后稳定型(PS,n=14)假体,与14名健康对照比较术后约12个月下3级楼梯时的膝关节生物力学与肌肉活动。PS组在单腿支撑期膝关节屈曲角度更小、腘绳肌激活更高,MBS组与PS组膝关节力矩和功率相似但均未达到对照组水平。
要点
- PS组下楼梯时膝关节屈曲角度小于MBS组和对照组,腘绳肌激活高于MBS组和对照组。
- MBS组与PS组膝关节力矩和功率相似,但两组均未达到对照组水平。
- 作者认为MBS假体设计可能提供额外稳定性,因患者所需肌肉活动少于PS组。
核心结论
- PS组下楼梯时膝关节屈曲角度更小且腘绳肌活动增加,表明其步态模式较MBS组更僵硬。
- 作者认为MBS假体设计可能提供额外稳定性,因患者所需肌肉活动少于PS组。
研究设计与样本
- 28例全膝关节置换患者随机分为MBS组(n=14)和PS组(n=14),并与14名健康对照比较。
- 患者于全膝关节置换术后约12个月在生物力学实验室下3级楼梯时测量膝关节生物力学和肌肉活动。
主要发现
- 与MBS组和对照组相比,PS组在整个单腿支撑期下楼梯时膝关节屈曲角度减小且腘绳肌激活增加。
- MBS组与PS组膝关节力矩和功率相似,但两组均未达到对照组水平。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Many patients report more difficulty when descending stairs compared to level walking after total knee arthroplasty (TKA). Different implant designs can affect knee biomechanics and muscle activity during gait, but their effect during stair descent is unclear. The purpose of this study was to evaluate knee biomechanics and muscle activations of quadriceps, hamstrings, and gastrocnemius muscles during a stair descent task in patients who underwent TKA with either a posterior stabilized (PS) or medial ball-and-socket (MBS) implant and to compare them to a group of healthy controls. METHODS: There were 28 TKA patients who were randomized to either an MBS (n = 14) or PS (n = 14) implant and were compared with 14 controls. Patients visited the biomechanics lab approximately 12 months after TKA, where knee biomechanics and muscle activity were measured as they descended a 3-step staircase. RESULTS: Compared to the MBS and control groups, the PS group descended the stairs with a reduced knee flexion angle and greater hamstring muscle activation throughout single limb support. Knee joint moments and power were similar between the MBS and PS groups, but neither reached the level of the control group. CONCLUSIONS: Lower knee flexion angles and increased hamstring muscle activity indicated that the PS group descended the stairs with a stiffer knee gait pattern than the MBS group. The MBS implant design may provide additional stability as patients require less muscle activity than the PS group.
引用
- Kowalski E, Pelegrinelli ARM, Ryan N, et al. Muscle Activity and Biomechanics While Descending a Staircase After Total Knee Arthroplasty: A Study Comparing Different Posterior Stabilized and Medial Ball-and-Socket Designs. J Arthroplasty. 2024. PMID: 38901712. doi:10.1016/j.arth.2024.06.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。