传统与新型全羟基磷灰石涂层股骨柄的股骨皮质骨接触状态及假体周围骨密度变化存在差异

Contact states with femoral cortical bone and periprosthetic bone mineral density changes differ between traditional and newly introduced fully hydroxyapatite-coated stems.
PubMed 文献 · Bone Joint J · 2024-06-01

本研究比较了传统全羟基磷灰石(HA)涂层股骨柄(T-HA组,36例)与新型全HA涂层股骨柄(N-HA组,30例)全髋关节置换术后的初始固定模式和假体周围骨密度变化。N-HA组在Gruen 3、5、6区接触面积显著更大,提示远端固定模式;术后两年N-HA组股骨近端内侧(6区)骨密度显著下降而T-HA组显著升高。两组骨密度变化与BMI或术前腰椎骨密度相关,而非与皮质骨接触范围相关。

要点

  • N-HA组在Gruen 3、5、6区的接触面积显著大于T-HA组,提示远端固定模式。
  • 术后两年N-HA组6区骨密度显著下降,T-HA组显著升高。
  • 两组骨密度变化与BMI或术前腰椎骨密度相关,与皮质骨接触范围无关。

核心结论

  • 与传统全HA涂层股骨柄相比,新型全HA涂层股骨柄显示显著更大的接触面积,提示远端固定模式。
  • 传统全HA涂层股骨柄在术后两年表现出更好的假体周围骨密度保留。
  • 作者认为,在选择全HA涂层股骨柄行全髋关节置换术时,应考虑这些固定模式和骨密度差异,以改善长期结局。

研究设计与样本

  • 本研究纳入使用传统全HA涂层股骨柄的患者36例(T-HA组)和使用新型全HA涂层股骨柄的患者30例(N-HA组)。
  • 采用双能X线吸收法测量术后一年和两年的假体周围骨密度变化。
  • 使用密度映射系统评估股骨柄与股骨皮质骨之间的三维接触,并记录包括患者报告结局测量在内的临床评估。

主要发现

  • N-HA组在Gruen 3、5、6区的接触面积显著大于T-HA组。
  • 术后两年,N-HA组股骨近端内侧(6区)骨密度显著下降,T-HA组显著升高。
  • 两组骨密度变化与BMI或术前腰椎骨密度相关,而非与股骨皮质骨接触范围相关。

临床怎么用

  • 作者认为,外科医生在选择全HA涂层股骨柄行全髋关节置换术时,应考虑这些固定模式和骨密度差异,以改善长期结局。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). METHODS: The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. RESULTS: There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. CONCLUSION: The N-HA-coated stem showed a significantly larger contact area, indicating a distal fixation pattern, compared with the traditional fully HA-coated stem. The T-HA-coated stem showed better preservation of periprosthetic BMD, two years postoperatively. Surgeons should consider these patterns of fixation and differences in BMD when selecting fully HA-coated stems for THA, to improve the long-term outcomes.