手术室空气可能携带病原体:紫外线空气过滤装置的作用

Operating Room Air May Harbor Pathogens: The Role of an Ultraviolet Air Filtration Unit.
PubMed 文献 · J Arthroplasty · 2024-05-31

在单机构前瞻性研究中,于正压通风并加装晶体紫外-C(C-UVC)灭菌灯过滤装置的手术室内同步采集进出口气流拭子,200份拭子中19份(9.5%)分离出微生物,进气口拭子阳性率高于出气口(16% vs 3%,P < .01),开门次数更多时微生物检出也更高(32.5 ± 7.1 vs 27.9 ± 5.6,P < .01)。

要点

  • 200份空气拭子中19份(9.5%)分离出微生物。
  • 进气口拭子阳性率16%高于出气口3%(P < .01)。
  • 开门次数更多时微生物检出更高(32.5 ± 7.1 vs 27.9 ± 5.6,P < .01)。

核心结论

  • 空气拭子主要从通向C-UVC过滤装置的进气气流中分离出微生物,该灭菌装置可抵消开门、手术人员和组织燃烧等影响手术室空气质量的因素。

研究设计与样本

  • 单机构前瞻性研究,在行初次全关节置换和脊柱手术、配备正压通风系统并加装C-UVC灭菌灯过滤装置的手术室中,同步采集进气与出气气流拭子并进行培养和下一代测序。

主要发现

  • 所采样手术的平均时长为68 ± 13分钟。
  • 200份拭子中19份(9.5%)分离出微生物,进气口拭子阳性率16%高于出气口3%(P < .01)。
  • 分离出多种革兰阳性、革兰阴性和厌氧细菌,真菌仅从进气口拭子中回收。
  • 开门次数更多时微生物检出更高(32.5 ± 7.1 vs 27.9 ± 5.6;P < .01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: One important factor for the prevention of surgical site infections is ultraclean air in the operating room (OR). Still, the direct sterilization potential of most technologies, especially in a dynamic clinical setting, is not well understood. We aimed to determine and compare the microbial presence from the inlet and outlet flow of a filtration unit with crystalline ultraviolet-C (C-UVC) light. METHODS: A prospective study was conducted at a single institution, where primary total joint arthroplasty and spine surgeries were performed. The OR was fitted with a positive ventilation system. In addition, a filtration unit with a C-UVC sterilizing light was placed in the OR. The inlet and outlet air flows were swabbed simultaneously and compared. Swabs were processed for culture and next-generation sequencing. RESULTS: The mean length of the surgical procedures sampled was 68 ± 13 minutes. Overall, 19 out of 200 (9.5%) swabs isolated microorganisms. Inlet air swabs were positive at a higher rate (16 versus 3%; P < .01) compared to the outlet air swabs. A wide variety of Gram-positive, Gram-negative, and anaerobic bacteria were isolated, but fungi were only recovered from inlet air swabs. The detection of microorganisms was also higher when more door openings were performed (32.5 ± 7.1 versus 27.9 ± 5.6; P < .01). CONCLUSIONS: Air swabs mainly isolated microorganisms from the inlet flow to the filtration unit with a C-UVC light. The sterilizing unit counteracted factors affecting the air quality in the OR, namely door openings, surgical personnel, and tissue combustion.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Fernández-Rodríguez D, Tarabichi S, Golankiewicz K, et al. Operating Room Air May Harbor Pathogens: The Role of an Ultraviolet Air Filtration Unit. J Arthroplasty. 2024. PMID: 38823518. doi:10.1016/j.arth.2024.05.072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。