手术室空气微生物负荷:非刷手人员着装的影响
本研究通过隔离舱和功能手术室两种方法,比较医院洗涤刷手服与一次性连体防护服对空气中微生物负荷的影响。结果显示,穿刷手服时沉降菌落数和空气颗粒浓度均显著高于穿连体防护服时,作者认为连体防护服的一体式设计可限制污染颗粒逸出。
要点
- 在隔离舱中,穿刷手服的沉降率为5519±1381 CFU/m²/h,穿连体防护服为505±55 CFU/m²/h(P=.008)。
- 在手术室中,穿刷手服时沉降率为218.7±35 CFU/m²/h,穿连体防护服为50.5±13 CFU/m²/h(P<.01)。
- 穿刷手服时空气颗粒浓度为4952.1±495 particles/m³,穿连体防护服为1065±53 particles/m³(P<.01),分别降低77%和79%。
核心结论
- 标准刷手服的开放式设计使污染颗粒逸出至手术室环境,而连体防护服的一体式设计限制了逸出途径;结果可能有助于制定医院感染预防政策。
研究设计与样本
- 研究比较医院洗涤刷手服与一次性连体防护服,采用两种方法:隔离舱受控环境测试和功能手术室标准化模拟操作;每个阶段同一人同一天完成两次测试。
主要发现
- 隔离舱中,刷手服沉降率为5519±1381 CFU/m²/h,连体防护服为505±55 CFU/m²/h(P=.008),组间约10倍差异。
- 手术室中,刷手服沉降率为218.7±35 CFU/m²/h,连体防护服为50.5±13 CFU/m²/h(P<.01)。
- 手术室中,刷手服空气颗粒浓度为4952.1±495 particles/m³,连体防护服为1065±53 particles/m³(P<.01),两项指标分别降低77%和79%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Infection is a leading cause of total joint arthroplasty failure. In previous studies, we found correlations between the level of contamination, concentrations of airborne particles, and the number of staff present. In this study, we focused on the apparel of nonscrubbed operating room (OR) staff to elucidate their contribution to the airborne microbial load. METHODS: We compared hospital-laundered scrubs to disposable coveralls using 2 methods. (1) Participants entered an isolation chamber with a controlled environment and completed tasks for 1 hour wearing both the approved and alternative OR attire. Settle plates collected viable contaminants that were shed by the participants during testing. (2) Lab members conducted standardized maneuvers in a functional OR that simulated typical movements of the nurse, anesthesiologist, implant representative, and entering/exiting staff. An airborne particle counter and settle plates were positioned throughout the OR. After 1 hour, the staff changed apparel and repeated the test. Each session of both phases consisted of 2 tests by the same individuals on the same day. RESULTS: There was approximately a 10-fold difference in the settlement rate of viable particles between groups when employing the isolation chamber. The settle rate for scrubs was 5,519 ± 1,381 colony forming units (CFUs)/m2/h, while the settle rate for coveralls was 505 ± 55 CFUs/m2/h (P = .008). During testing in the OR, 218.7 ± 35 CFUs/m2/h were captured for scrubs, compared with 50.5 ± 13 CFUs/m2/h for the coverall (P < .01). The concentration of airborne particles collected for scrubs was 4,952.1 ± 495 particles/m3 and 1,065 ± 53 particles/m3 for the coveralls (P < .01). This was a 77% and 79% reduction for both measures, respectively. CONCLUSIONS: The open nature of standard scrubs allows contaminated particles to escape into the OR environment, whereas the one-piece design of the coveralls restricts pathways of escape. The results of this study may be helpful when developing hospital infection prevention policies.
引用
- Zuskov A, Jones HL, Crowley BP, et al. Operating Room Airborne Microbial Load: Nonscrubbed Staff Apparel Matters. J Arthroplasty. 2024. PMID: 38909853. doi:10.1016/j.arth.2024.06.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。