文献速递关节外科

农村患者全关节置换术后出院风险计算器的验证

Validation of a Discharge Risk Calculator for Rural Patients Following Total Joint Arthroplasty.
PubMed 文献 · J Arthroplasty · 2024-06-24

该研究基于2012年1月至2022年9月本机构9477例全膝关节置换(TKA,39.6%)和全髋关节置换(THA,60.4%)病例,验证一个利用9项术前变量预测出院至 skilled nursing facility 与家庭的预测模型。在风险评分截断值0.23时,总体正确分类比例为0.723,曲线下面积为0.788,灵敏度和特异度分别为0.720和0.723,均高于既往在城市人群中的验证水平。作者结论认为该风险计算器在农村TKA和THA患者中预测出院地点具有很好的准确度、灵敏度和特异度。

要点

  • 在9477例农村患者中验证出院风险计算器,总体正确分类比例为0.723,曲线下面积为0.788。
  • 截断值0.23时灵敏度0.720、特异度0.723,均高于既往城市人群验证水平。
  • 模型提供易用界面并自动化提取变量,作者认为可辅助术后出院计划的共享决策。

核心结论

  • 该风险计算器在农村TKA和THA患者中预测出院地点显示出很好的准确度、灵敏度和特异度,准确度甚至高于城市人群。

研究设计与样本

  • 回顾性收集2012年1月至2022年9月本机构所有TKA和THA手术,共纳入9477例(TKA占39.6%,THA占60.4%)进行验证分析。
  • 从电子病历中自动化提取9项术前变量,输入预测模型生成出院至 skilled nursing facility 与家庭的风险评分。

主要发现

  • 使灵敏度和特异度最大化的评分截断值为0.23。
  • 该研究人群中预测工具的正确分类比例为0.723,曲线下面积为0.788,两者均高于既往发表的准确度水平。
  • 截断值0.23时,灵敏度为0.720,特异度为0.723。

关键数值与推荐

  • 风险评分截断值0.23对应灵敏度0.720、特异度0.723、正确分类比例0.723、曲线下面积0.788。

临床怎么用

  • 作者认为该模型提供易用界面,自动化代表一种可行工具,有助于术后出院计划的共享决策。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: As the volume of total joint arthroplasty in the US continues to grow, new challenges surrounding appropriate discharge surface. Arthroplasty literature has demonstrated discharge disposition to postacute care facilities carries major risks regarding the need for revision surgery, patient comorbidities, and financial burden. To quantify, categorize, and mitigate risks, a decision tool that uses preoperative patient variables has previously been published and validated using an urban patient population. The aim of our investigation was to validate the same predictive model using patients in a rural setting undergoing total knee arthroplasty (TKA) and total hip arthroplasty. METHODS: All TKA and THA procedures that were performed between January 2012 and September 2022 at our institution were collected. A total of 9,477 cases (39.6% TKA, 60.4% THA) were included for the validation analysis. There were 9 preoperative variables that were extracted in an automated fashion from the electronic medical record. Included patients were then run through the predictive model, generating a risk score representing that patient's differential risk of discharge to a skilled nursing facility versus home. Overall accuracy, sensitivity and specificity were calculated after obtaining risk scores. RESULTS: Score cutoff equally maximizing sensitivity and specificity was 0.23, and the proportion of correct classifications by the predictive tool in this study population was found to be 0.723, with an area under the curve of 0.788 - both higher than previously published accuracy levels. With the threshold of 0.23, sensitivity and specificity were found to be 0.720 and 0.723, respectively. CONCLUSIONS: The risk calculator showed very good accuracy, sensitivity, and specificity in predicting discharge location for rural patients undergoing TKA and THA, with accuracy even higher than in urban populations. The model provides an easy-to-use interface, with automation representing a viable tool in helping with shared decision-making regarding postoperative discharge plans.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Ozdag Y, Makar GS, Goltz DE, et al. Validation of a Discharge Risk Calculator for Rural Patients Following Total Joint Arthroplasty. J Arthroplasty. 2024. PMID: 38925275. doi:10.1016/j.arth.2024.06.047

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。