文献速递关节外科

多孔钽与定制三翼假体治疗髋臼缺损伴骨盆不连续患者的虚拟生物力学评估

Virtual biomechanical assessment of porous tantalum and custom triflange components in the treatment of patients with acetabular defects and pelvic discontinuity.
PubMed 文献 · Bone Joint J · 2024-05-01

本研究基于十例因Paprosky IIIB型髋臼缺损伴骨盆不连续行翻修全髋关节置换术并采用TMARS重建患者的术前术后CT,构建TMARS实际重建与虚拟CTAC假体的计算机模型,比较骨移除量、假体-骨贴合面积和髋关节旋转中心恢复。结果显示TMARS骨移除量中位数显著大于CTAC,总体假体-骨贴合面积无显著差异,但贴合区域分布不同,髋关节旋转中心平均差异为11.1 mm。

要点

  • TMARS骨移除量中位数显著大于CTAC(9.07 cm3 vs 1.16 cm3,p=0.004)。
  • 总体假体-骨贴合面积中位数两组无显著差异(54.8 cm2 vs 56.6 cm2,p=0.683)。
  • TMARS在残留髋臼内贴合更多,CTAC在骨盆外皮质贴合更多。

核心结论

  • 使用TMARS时骨移除量更多,从而在残留髋臼骨内获得更多假体-骨贴合。
  • CTAC假体骨移除量极小,假体-骨贴合更均匀地分布于残留髋臼与骨盆外皮质之间。
  • 这些差异提示用于治疗骨盆不连续的这两种假体可能通过不同的生物力学机制实现短期和长期稳定性。

研究设计与样本

  • 回顾性收集十例因Paprosky IIIB型髋臼缺损伴骨盆不连续行翻修全髋关节置换术并采用TMARS重建患者的术前和术后CT扫描。
  • 根据这些患者的术前CT设计CTAC假体的计算机模型。
  • 采用半自动方法从术后CT分割出TMARS重建的计算机模型。
  • 比较所有实际TMARS假体与虚拟CTAC假体之间的骨移除量、实现的假体-骨贴合面积以及髋关节旋转中心恢复情况。

主要发现

  • TMARS重建的骨移除量中位数显著大于CTAC假体(9.07 cm3(四分位距(IQR)5.86至21.42)vs 1.16 cm3(IQR 0.42至3.53),p=0.004)。
  • TMARS重建与CTAC假体的总体假体-骨贴合面积中位数无显著差异(54.8 cm2(IQR 28.2至82.3)vs 56.6 cm2(IQR 40.6至69.7),p=0.683)。
  • TMARS在残留髋臼内的假体-骨贴合面积显著更多(45.2 cm2(IQR 28.2至72.4)vs 25.5 cm2(IQR 12.8至44.1),p=0.001)。
  • TMARS与CTAC相比,与骨盆外皮质的贴合面积显著更少(0 cm2(IQR 0至13.1)vs 23.2 cm2(IQR 16.4至30.6),p=0.009)。
  • TMARS重建的髋关节旋转中心与CTAC假体相比平均差异为11.1 mm(3至28)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) - the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) - using virtual modelling. METHODS: Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. RESULTS: The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm3 (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm3 (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm2 (IQR 28.2 to 82.3) vs 56.6 cm2 (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm2 (IQR 28.2 to 72.4) vs 25.5 cm2 (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm2 (IQR 0 to 13.1) vs 23.2 cm2 (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. CONCLUSION: In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms.

来源:Bone Joint J,查看原文。版权归原作者所有。