文献速递关节外科小儿骨科

非骨水泥髋臼重建联合股骨头块状自体骨移植治疗Crowe IV型发育性髋关节发育不良的最小10年生存率

Minimum 10-Year Survivorship of Uncemented Acetabular Reconstruction With Bulk Femoral Head Autografting in Crowe Type IV Developmental Hip Dysplasia.
PubMed 文献 · J Arthroplasty · 2024-05-10

研究纳入35例(42髋)Crowe IV型发育性髋关节发育不良患者,行非骨水泥髋臼杯固定联合股骨头块状自体骨移植,平均随访15.0年。以髋臼组件翻修为终点的Kaplan-Meier 15年生存率为90.4%。移植骨平均水平覆盖率为46.1%,所有病例均出现骨小梁桥接与重塑,作者认为该方法是恢复骨储备和获得长期固定的良好方法。

要点

  • 35例(42髋)Crowe IV型发育性髋关节发育不良患者平均随访15.0年,15年假体生存率90.4%。
  • 移植骨平均水平覆盖率46.1%,覆盖<50%与≥50%组杯周<1mm透亮线无显著差异(4 vs 2髋,P=.446)。
  • 所有病例均出现骨小梁桥接和重塑,平均时间分别为术后4.1个月和9.0个月。

核心结论

  • 采用股骨头块状骨移植进行髋臼重建治疗Crowe IV型发育性髋关节发育不良可获得高生存率,是恢复骨储备和获得长期固定的良好方法。

研究设计与样本

  • 回顾性随访35例(42髋)Crowe IV型发育性髋关节发育不良患者,均行非骨水泥髋臼杯固定联合股骨头块状自体骨移植,平均随访15.0年(范围10.0至20.0年)。
  • 采用骨盆正位X线片测量移植骨水平覆盖率和中心边缘角,以髋臼组件翻修为终点进行Kaplan-Meier生存分析。

主要发现

  • Kaplan-Meier分析显示15年生存率为90.4%。
  • 移植骨平均水平覆盖率为46.1%(范围23.7至66.0),其中16例水平覆盖率≥50%。
  • 杯周<1mm透亮线在移植骨水平覆盖率<50%组与≥50%组之间无差异(4髋 vs 2髋;P=.446)。
  • 所有病例均出现骨小梁桥接和重塑,平均时间分别为术后4.1个月和9.0个月。
  • 41/42髋(97.6%)在平均随访19.9个月时出现骨小梁重新定向。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In total hip arthroplasty (THA) for severe dislocations such as Crowe type IV developmental dysplasia of the hip (DDH), sufficient bone volume for stable fixation of the acetabular component can be achieved by placing a reinforcing bone graft prepared from the resected femoral head into the deficient acetabulum. The purpose of the current study was to examine the long-term survivorship of uncemented THA in conjunction with a bulk femoral head autograft in patients who have Crowe type IV DDH. METHODS: A total of 35 patients (42 hips) who have Crowe type IV DDH and underwent THA using uncemented cup fixation with bulk femoral head autografting were followed up for a mean period of 15.0 years (range, 10.0 to 20.0) postoperatively. Anteroposterior pelvic radiographs were used for measurements such as the horizontal coverage of the grafted bone and the center-edge angle. Kaplan-Meier survivorship analyses were performed with revision of the acetabular component as the endpoint. RESULTS: The Kaplan-Meier analysis indicated 15-year survival rates of 90.4%. The mean horizontal coverage of grafted bone was 46.1% (range, 23.7 to 66.0), and there were 16 cases with horizontal coverage of ≥ 50%. There was no difference in the appearance of a thin (< 1 mm) radiolucency line around the cup between cases with < 50% versus ≥ 50% of the horizontal coverage of grafted bone (4 versus 2 hips; P = .446). Trabecular bridging and remodeling were seen in all cases after mean periods of 4.1 and 9.0 months postoperatively, respectively. Trabecular reorientation was seen in 41 of 42 hips (97.6%) at a mean follow-up of 19.9 months. CONCLUSIONS: Acetabular reconstruction with femoral bulk bone grafting for Crowe type IV DDH resulted in high survival rates and was a good method to restore bone stock and obtain long-term fixation.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Suzuki M, Masuda T, Kanno T, et al. Minimum 10-Year Survivorship of Uncemented Acetabular Reconstruction With Bulk Femoral Head Autografting in Crowe Type IV Developmental Hip Dysplasia. J Arthroplasty. 2024. PMID: 38735553. doi:10.1016/j.arth.2024.05.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。