文献速递关节外科

全膝关节置换术后反应不佳分类不足:基于荷兰关节置换登记处与骨关节炎倡议数据库对15种定义的比较分析

Inadequate Classification of Poor Response After Total Knee Arthroplasty: A Comparative Analysis of 15 Definitions Using Data From the Dutch Arthroplasty Register and the Osteoarthritis Initiative Database.
PubMed 文献 · J Arthroplasty · 2024-05-15

研究利用荷兰关节置换登记处(n=12,275)和骨关节炎倡议数据库(n=204)的全膝关节置换术后1年数据,比较15种反应不佳定义的患病率、重叠度(Cohen kappa)和区分准确性。结果显示不同定义间重叠度不足,中位患病率18.5%,中位敏感性0.45、特异性0.86,结论认为现有定义均不能充分分类反应不佳者,但可较有把握地排除反应不佳。

要点

  • 15种反应不佳定义的中位患病率为18.5%(25th-75th百分位14.0-25.5%)。
  • 定义两两间重叠的中位Cohen kappa为0.41(0.32-0.59),提示重叠不足。
  • 中位敏感性0.45、特异性0.86,阳性预测值0.45,阴性预测值0.89。

核心结论

  • 本研究发现全膝关节置换术后反应不佳的不同定义之间缺乏重叠,所检验的定义均不能充分分类反应不佳者,而排除反应不佳则较有把握。

研究设计与样本

  • 使用荷兰关节置换登记处初次全膝关节置换术后1年患者(n=12,275)和骨关节炎倡议数据库患者(n=204)的数据,比较15种反应不佳定义的患病率、重叠度(Cohen kappa)和区分准确性。

主要发现

  • 所检验定义中反应不佳者的中位患病率为18.5%(25th-75th百分位14.0-25.5%)。
  • 定义两两间重叠的中位Cohen kappa为0.41(0.32-0.59)。
  • 中位敏感性为0.45(0.39-0.54),特异性为0.86(0.82-0.94),阳性预测值为0.45(0.34-0.62),阴性预测值为0.89(0.87-0.89),Youden指数为0.36(0.20-0.43)。

关键数值与推荐

  • 以数字评定量表满意度≤6分为反应不佳锚定标准(用于荷兰关节置换登记处数据集),以膝关节影响整体评估二分≥4分为反应不佳锚定标准(用于骨关节炎倡议数据集)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Variations in defining poor response to total knee arthroplasty (TKA) impede comparisons of response after TKA over time and across hospitals. This study aimed to compare the prevalence, overlap, and discriminative accuracy of 15 definitions of poor response after TKA using 2 databases. METHODS: Data of patients one year after primary TKA from the Dutch Arthroplasty Register (n = 12,275) and the Osteoarthritis Initiative database (n = 204) were used to examine the prevalence, overlap (estimated by Cohen's kappa), and discriminative accuracy (sensitivity, specificity, positive predictive value, negative predictive value, and Youden index) of 15 different definitions of poor response after TKA. In the absence of a gold standard for measuring poor response to TKA, the numeric rating scale satisfaction (≤ 6 'poor responder') and the global assessment of knee impact (dichotomized: ≥ 4 'poor responder') were used as anchors for assessing discriminative accuracy for the Dutch Arthroplasty Register and Osteoarthritis Initiative dataset, respectively. These anchors were chosen based on a prior qualitative study that identified (dis)satisfaction as a central theme of poor responses to TKA by patients and knee specialists. RESULTS: The median (25th to 75th percentile) prevalence of poor responders in the examined definitions was 18.5% (14.0 to 25.5%), and the median Cohen's kappa for the overlap between pairs of definitions was 0.41 (0.32 to 0.59). Median (25th to 75th percentile) sensitivity was 0.45 (0.39 to 0.54), specificity was 0.86 (0.82 to 0.94), positive predictive value was 0.45 (0.34 to 0.62), negative predictive value was 0.89 (0.87 to 0.89), and the Youden index was 0.36 (0.20 to 0.43). CONCLUSIONS: This study found a lack of overlap between different definitions of poor response to TKA. None of the examined definitions adequately classified poor responders to TKA. In contrast, the absence of a poor response could be classified with confidence.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Te Molder MEM, Dowsey MM, Smolders JMH, et al. Inadequate Classification of Poor Response After Total Knee Arthroplasty: A Comparative Analysis of 15 Definitions Using Data From the Dutch Arthroplasty Register and the Osteoarthritis Initiative Database. J Arthroplasty. 2024. PMID: 38759818. doi:10.1016/j.arth.2024.05.032