环扎线缆对不稳定股骨颈骨折使用非骨水泥股骨柄时预防假体周围股骨骨折的效果
这项回顾性研究纳入329例因股骨颈骨折行非骨水泥股骨柄髋关节置换的患者,比较无环扎组159例与环扎组170例。环扎组术中假体周围股骨骨折(iPFF)和术后假体周围股骨骨折(pPFF)发生率均显著低于无环扎组,且不增加手术时间或失血量。
要点
- 无环扎组iPFF发生率6.3%,环扎组0%,差异有统计学意义(P < .001)。
- 无环扎组pPFF发生率5.1%,环扎组0.6%,差异有统计学意义(P = .016)。
- 两组手术时间和失血量无显著差异。
核心结论
- 在不稳定股骨颈骨折使用非骨水泥股骨柄时,环扎线缆可有效预防术中及术后假体周围股骨骨折,且不增加手术时间或失血量。
研究设计与样本
- 回顾性研究,纳入329例因股骨颈骨折行非骨水泥股骨柄髋关节置换的连续患者,无环扎组159例,环扎组170例,两组患者特征可比。
主要发现
- iPFF发生率无环扎组6.3% vs 环扎组0%(P < .001)。
- pPFF发生率无环扎组5.1% vs 环扎组0.6%(P = .016)。
- 无环扎组再手术率5.1%,环扎组0%(P = .003),环扎组1例为日间手术病例、无需再手术。
- 手术时间无环扎组50分钟 vs 环扎组52分钟(P = .244),失血量无环扎组133 mL vs 环扎组149 mL(P = .212),均无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Periprosthetic femoral fractures (PFFs) are serious complications in hip arthroplasty for femoral neck fractures. The rates of intraoperative (iPFFs) and postoperative PFFs (pPFFs) are higher in cementless stem cases than in cemented cases. This study aimed to investigate the effects of cerclage cabling on PFF prevention in cementless arthroplasty for femoral neck fractures. METHODS: This retrospective study included 329 consecutive patients who underwent hip arthroplasty using a cementless stem for femoral neck fractures. A total of 159 and 170 patients were in the non-cabling and cabling groups, respectively. Patient characteristics were comparable in both groups. The PFF occurrence (iPFF and pPFF) rates, reoperation rates, operative time, and blood loss volume were compared between the groups. RESULTS: The iPFF rate was significantly higher in the noncabling group (6.3%) than in the cabling group (0%, P < .001). The rate of pPFF was significantly higher in the non-cabling group (5.1%) than in the cabling group (0.6%; P = .016). All patients in the non-cabling group required reoperation (5.1%), whereas the patient in the cabling group was an ambulatory case and required no reoperation (0%, P = .003). No significant difference in either operative time or blood loss volume was observed between the non-cabling (50 minutes, 133 mL) and cabling (52 minutes, P = .244; 149 mL, P = .212, respectively) groups. CONCLUSIONS: When a cementless stem is used to treat unstable femoral neck fractures, cerclage cabling effectively prevents iPPF and pPPF without increasing surgical time or blood loss volume.
引用
- Iwasa M, Ando W, Takashima K, et al. Effects of Cerclage Cabling on Preventing Periprosthetic Femoral Fractures When Using Cementless Stems for Unstable Femoral Neck Fractures. J Arthroplasty. 2024. PMID: 38735547. doi:10.1016/j.arth.2024.04.085
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。