文献速递关节外科创伤骨科

双动髋臼假体降低不稳定但可能并非复发性脱位全髋翻修术的唯一答案

Dual-mobility bearings reduce instability but may not be the only answer in revision total hip arthroplasty for recurrent dislocation.
PubMed 文献 · Bone Joint J · 2024-05-01

回顾性分析86例因脱位行全髋翻修术的连续病例,比较双动假体(38例)、标准假体(39例)和限制性内衬(9例)的再脱位率与再翻修率。双动假体再脱位率13.2%,标准假体17.9%,限制性内衬22.2%(p=0.432);双动假体再翻修无生存率84% vs 标准假体74% vs 限制性内衬67%(p=0.361)。外展肌缺陷是持续不稳定的重要预测因素。

要点

  • 双动假体再脱位率13.2%,标准假体17.9%,限制性内衬22.2%,差异无统计学显著(p=0.432)。
  • 双动假体再翻修无生存率84%,标准假体74%,限制性内衬67%,差异无统计学显著(p=0.361)。
  • 外展肌缺陷是持续不稳定的重要预测因素,所有再脱位的双动假体均用于外展肌缺陷患者。

核心结论

  • 双动假体降低了复发性脱位全髋翻修术的再脱位率和再翻修率,但并未保证稳定性。
  • 外展肌缺陷是持续不稳定的重要预测因素。

研究设计与样本

  • 回顾性分析了2012年8月至2019年7月间因脱位行全髋翻修术的86例连续病例。
  • 38例(44.2%)使用双动假体,39例(45.3%)使用标准假体,9例(10.5%)使用限制性内衬。
  • 患者翻修时平均年龄70岁(范围43至88岁),女性54例(62.8%),平均随访5.0年(范围2.0至8.75年)。
  • 采用Cox回归分析确定再脱位的危险因素。

主要发现

  • 双动假体在老年患者中使用的频率显著更高(p=0.003),在外展肌缺陷的髋关节中也显著更高(p<0.001)。
  • 再脱位率:双动假体13.2%,标准假体17.9%,限制性内衬22.2%(p=0.432)。
  • 再翻修无生存率:双动假体84%(95%CI 0.77至0.91),标准假体74%(95%CI 0.67至0.81),限制性内衬67%(95%CI 0.51至0.82)(p=0.361)。
  • 再脱位的显著相关因素包括:较年轻年龄(HR 0.92,95%CI 0.85至0.99;p=0.031)、较低合并症(HR 0.44,95%CI 0.20至0.95;p=0.037)、较小股骨头(HR 0.80,95%CI 0.64至0.99;p=0.046)和保留髋臼假体(HR 8.26,95%CI 1.37至49.96;p=0.022)。
  • 所有再脱位的双动假体均用于外展肌缺陷患者(HR 48.34,95%CI 0.03至7737.98;p=0.303)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. METHODS: We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75). RESULTS: DM bearings were used significantly more frequently in elderly patients (p = 0.003) and in hips with abductor deficiency (p < 0.001). The re-dislocation rate was 13.2% for DM bearings compared with 17.9% for standard bearings, and 22.2% for constrained liners (p = 0.432). Re-revision-free survival for DM bearings was 84% (95% confidence interval (CI) 0.77 to 0.91) compared with 74% (95% CI 0.67 to 0.81) for standard articulations, and 67% (95% CI 0.51 to 0.82) for constrained liners (p = 0.361). Younger age (hazard ratio (HR) 0.92 (95% CI 0.85 to 0.99); p = 0.031), lower comorbidity (HR 0.44 (95% CI 0.20 to 0.95); p = 0.037), smaller heads (HR 0.80 (95% CI 0.64 to 0.99); p = 0.046), and retention of the acetabular component (HR 8.26 (95% CI 1.37 to 49.96); p = 0.022) were significantly associated with re-dislocation. All DM bearings which re-dislocated were in patients with abductor muscle deficiency (HR 48.34 (95% CI 0.03 to 7,737.98); p = 0.303). The radiological analysis did not reveal a significant relationship between restoration of the geometry of the hip and re-dislocation. The mean mHHSs significantly improved from 43 points (0 to 88) to 67 points (20 to 91; p < 0.001) at the final follow-up, with no differences between the types of bearing. CONCLUSION: We found that the use of DM bearings reduced the rates of re-dislocation and re-revision in revision THA for recurrent dislocation, but did not guarantee stability. Abductor deficiency is an important predictor of persistent instability.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Scholz J, Perka C, Hipfl C, et al. Dual-mobility bearings reduce instability but may not be the only answer in revision total hip arthroplasty for recurrent dislocation. Bone Joint J. 2024. PMID: 38688508. doi:10.1302/0301-620X.106B5.BJJ-2023-0828.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。