站立位下肢全长X线片与CT扫描在测量膝关节冠状位对线中的强相关性
这项多中心队列研究纳入3家三级中心300例初次机器人辅助膝关节置换术前患者,比较下肢全长X线片与CT扫描图测量冠状位对线的相关性,HKA、aHKA等指标呈强相关,JLCA相关性较弱,作者认为CT扫描图可可靠估计膝关节冠状位对线并可能替代下肢全长X线片。
要点
- HKA相关系数0.912、aHKA 0.883、LDFA 0.871、MPTA 0.820、JLO 0.778,均p<0.001。
- 膝外翻者JLCA相关性(Spearman系数0.412)弱于膝内翻者(0.518)。
- 初始JLCA在±5°以内与更高一致性相关,作者强调下肢摆位和严重畸形需警惕。
核心结论
- 在下肢全长X线片与CT扫描图之间观察到强相关性,提示CT扫描图可可靠用于估计膝关节冠状位对线,并可能替代下肢全长X线片的需求。
- 为获得更高一致性,确保下肢恰当的放射学摆位至关重要;此外,作者提醒外科医生在存在严重畸形时需警惕潜在差异。
研究设计与样本
- 多中心队列研究,覆盖3家三级中心,纳入300例因初次机器人辅助全膝关节置换术(TKA)或单髁膝关节置换术(UKA)而术前同时具备下肢全长X线片(LLR)和CT扫描图的患者。
- 测量指标包括胫骨近端内侧角(MPTA)、股骨远端外侧角(LDFA)、髋-膝-踝角(HKA)、关节线倾斜度(JLO)、关节线汇聚角(JLCA)和算术HKA(aHKA)。
- 证据等级:预后II级。
主要发现
- HKA(相关系数0.912)、aHKA(0.883)、MPTA(0.820)、LDFA(0.871)、JLO(0.778)在两种影像方式间均呈强相关,p<0.001。
- 膝外翻者JLCA的Spearman系数为0.412,膝内翻者为0.518,外翻膝相关性较弱。
- 回归模型显示,一致程度与术前关节内畸形及CT扫描时下肢的摆位(即下肢旋转角)相关。
- 初始JLCA在±5°以内与更高的一致性相关。
关键数值与推荐
- HKA相关系数0.912(p<0.001);aHKA 0.883(p<0.001);MPTA 0.820(p<0.001);LDFA 0.871(p<0.001);JLO 0.778(p<0.001)。
- JLCA的Spearman系数:膝外翻0.412 vs 膝内翻0.518(外翻膝相关性较弱)。
- 初始JLCA在±5°以内与更高一致性相关。
临床怎么用
- 作者认为CT扫描图可可靠用于估计膝关节冠状位对线,并可能替代下肢全长X线片的需求。
- 作者强调,为获得更高一致性需确保下肢恰当的放射学摆位。
- 作者提醒外科医生在存在严重畸形时需警惕两种影像间的潜在差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The objective of this study was to evaluate the correlation in measurements of the lower-limb coronal alignment between long-leg radiographs (LLRs) and computed tomography (CT) scanograms that were made during preoperative planning for robotic-arm-assisted knee arthroplasty. On the basis of published evidence demonstrating a good correlation between these imaging modalities in measuring the lower-limb mechanical axis, we hypothesized that there would be no significant differences between the 2 in the present study. METHODS: This multicenter cohort study across 3 tertiary centers included 300 patients undergoing primary robotic-arm-assisted total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA) for whom LLRs and CT scanograms were available preoperatively. The study involved measuring the medial proximal tibial angle (MPTA), lateral distal femoral angle (LDFA), hip-knee-ankle angle (HKA), joint line obliquity (JLO), joint-line convergence angle (JLCA), and arithmetic HKA (aHKA). The aHKA represents a method for estimating constitutional alignment using angles that are unaffected by joint-space narrowing. RESULTS: Strong correlations (p < 0.001) between the imaging modalities were found for the HKA (correlation coefficient, 0.912), aHKA (0.883), MPTA (0.820), LDFA (0.871), and JLO (0.778). A weaker correlation was observed for the JLCA in valgus knees as compared with varus knees (Spearman coefficients, 0.412 and 0.518, respectively). Regression models demonstrated that the degree of agreement was associated with the preoperative intra-articular deformity and the positioning of the lower limb during the CT scan (i.e., the lower-limb rotational angle). An initial JLCA within ±5° was associated with higher agreement. CONCLUSIONS: We observed a strong correlation between LLRs and CT scanograms that were made during the preoperative planning stage of robotic-arm-assisted knee arthroplasty, implying that CT scanograms can reliably be utilized to estimate the coronal alignment of the knee, potentially replacing the need for LLRs. Nevertheless, to attain a higher degree of agreement, it is crucial to ensure appropriate radiographic positioning of the lower limb. Additionally, surgeons must remain vigilant regarding potential discrepancies in cases involving substantial deformities. LEVEL OF EVIDENCE: Prognostic Level II . See Instructions for Authors for a complete description of levels of evidence.
引用
- Fontalis A, Luyckx T, Vanspauwen T, et al. Strong Correlation Between Standing Long-Leg Radiographs and CT Scans in Measuring Coronal Knee Alignment. J Bone Joint Surg Am. 2024. PMID: 38739702. doi:10.2106/JBJS.23.01092