骨干打压植骨联合干骺端锥形套:88例翻修全膝关节置换术的结局
本研究在88例翻修全膝关节置换术中采用干骺端锥形套联合骨干打压植骨与骨水泥柄的技术,平均随访4年,无锥形套-打压植骨构造因无菌性松动需再翻修,5年无任何翻修生存率95%,无任何再手术生存率65%,28%的膝关节进行了再手术。
要点
- 88例翻修全膝关节置换术采用干骺端锥形套联合骨干打压植骨与骨水泥柄,平均随访4年。
- 无锥形套-打压植骨构造因无菌性松动需再翻修;5年无任何翻修生存率95%,无任何再手术生存率65%。
- 28%的膝关节进行了再手术,最常见指征为假体周围感染和假体周围骨折。
核心结论
- 在硬化、抛光的骨干髓腔伴松质骨缺损及干骺端骨丢失时,本研究的骨干打压植骨联合干骺端锥形套技术在这组较大的病例系列中极其耐用。
- 无锥形套-打压植骨构造因无菌性松动需再翻修。
研究设计与样本
- 在本机构对88例翻修全膝关节置换术采用干骺端锥形套联合骨干打压植骨与骨水泥柄,其中35例来自既往研究。
- 翻修时平均年龄67岁,67%的患者为男性,患者既往平均接受过4次膝关节置换手术。
- 翻修最常见的两个原因为无菌性松动(78%)和因假体周围感染行二期再植入(19%),平均随访4年。
- 证据等级:治疗性IV级。
主要发现
- 末次随访时,无锥形套-打压植骨构造因无菌性松动需再翻修。
- 5年无任何锥形套-打压植骨构造翻修生存率为95%,无任何再手术生存率为65%。
- 共25膝(28%)进行了再手术,最常见的两个指征为假体周围感染和假体周围骨折。
- 所有锥形套均骨整合,所有植骨均表现为稳定或已整合。
- 1例患者影像学显示胫骨组件松动但锥形套固定良好,该患者无症状且在9年时未行翻修。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Metaphyseal cones with cemented stems can be successfully utilized in most revision total knee arthroplasties (TKAs). However, if the diaphysis has been previously violated, fixation of the cemented stem, which is important for cone ingrowth and construct survival, can be compromised. The initial results of our novel technique combining diaphyseal impaction bone-grafting with a metaphyseal cone were promising but required additional study. The purpose of the present study was to assess results of this technique in a larger cohort. METHODS: A metaphyseal cone combined with diaphyseal impaction grafting and a cemented stem was utilized in 88 revision TKAs at our institution, including 35 from our prior study. The mean age at the time of revision was 67 years, and 67% of patients were male. Patients had had a mean of 4 prior knee arthroplasty procedures. The 2 most common reasons for revision were aseptic loosening (78%) and 2-stage reimplantation for periprosthetic joint infection (PJI) (19%). The mean follow-up was 4 years. RESULTS: At the time of the latest follow-up, no cone-impaction grafting constructs required re-revision for aseptic loosening. Five-year survivorship free from any revision of the cone-impaction grafting construct and free from any reoperation was 95% and 65%, respectively. A total of 25 knees (28%) underwent reoperation, with the 2 most common indications being PJI and periprosthetic fracture. All cones were osseointegrated, and all bone graft appeared stable or incorporated. One patient had radiographic evidence of tibial component loosening despite a well-fixed cone; however, this patient was asymptomatic and had not undergone revision at 9 years. CONCLUSIONS: When presented with a sclerotic, polished diaphyseal canal with deficient cancellous bone and concomitant metaphyseal bone loss, our technique of combining diaphyseal impaction grafting with a metaphyseal cone proved extremely durable in this larger series of patients. No cone-impaction grafting constructs required re-revision for aseptic loosening. LEVEL OF EVIDENCE: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
引用
- Bedard NA, Dugdale EM, Couch CC, et al. Diaphyseal Impaction Grafting Combined with Metaphyseal Cones: Outcomes in 88 Revision Total Knee Arthroplasties. J Bone Joint Surg Am. 2024. PMID: 38691581. doi:10.2106/JBJS.23.01085
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。