模块化凹槽锥形股骨柄在既往感染全髋关节置换二期再植入中的应用
单中心236例因假体周围感染行二期再植入全髋关节置换并使用模块化凹槽锥形股骨柄,平均随访7年,15年任何翻修累积发生率为24%,主要原因为脱位和感染;仅8%翻修涉及股骨柄,无菌性松动翻修累积发生率1%,柄均影像学稳定。
要点
- 15年任何翻修累积发生率为24%,最常见翻修原因为脱位(25例)和感染(16例)。
- 15年任何股骨柄翻修累积发生率为8%,无菌性松动翻修累积发生率仅1%。
- 未翻修病例中柄下沉≥5 mm发生率为2%,末次随访所有柄影像学稳定。
核心结论
- 模块化凹槽锥形股骨柄在感染二期再植入全髋关节置换中表现耐久可靠,无菌性松动发生率很低,但15年任何翻修发生率为24%,主要归因于脱位和复发性假体周围感染。
研究设计与样本
- 单中心三级学术机构2000年9月至2020年9月共236例因假体周围感染行二期再植入全髋关节置换,使用两种设计的模块化凹槽锥形股骨柄,再植入时平均年龄65岁(SD 11),平均BMI 32 kg/m2(SD 7),46%(n=109)为女性,平均随访7年(SD 4),采用竞争风险模型校正死亡。
主要发现
- 15年任何翻修累积发生率为24%,共48例翻修,最常见原因为脱位(n=25)和感染(n=16)。
- 15年任何再手术累积发生率为28%。
- 仅13例翻修涉及凹槽锥形股骨柄组件,15年该组件任何翻修累积发生率为8%。
- 仅2例凹槽锥形股骨柄因无菌性松动翻修,15年该组件无菌性松动翻修累积发生率为1%。
- 未翻修病例中柄下沉≥5 mm发生率为2%,末次随访所有柄影像学稳定,末次随访平均Harris髋关节评分69分(SD 20)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Uncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants - modular fluted tapered (MFT) femoral components - in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components. METHODS: We identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used. RESULTS: The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n = 25) and infection (n = 16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only two FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence ≥ 5 mm occurred in 2% of unrevised cases. All stems were radiologically stable at most recent follow-up. Mean Harris Hip Score was 69 (SD 20) at most recent follow-up. CONCLUSION: This series demonstrated that MFT components were durable and reliable in the setting of two-stage reimplantation THA for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily due to dislocation and recurrent PJI.
引用
- Carender CN, Perry KI, Sierra RJ, et al. Modular fluted tapered stems in two-stage reimplantation of previously infected total hip arthroplasties. Bone Joint J. 2024. PMID: 38688510. doi:10.1302/0301-620X.106B5.BJJ-2023-0788.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。