金属与陶瓷肱骨头全肩关节置换及半肩关节置换的翻修率比较
基于英国国家关节登记(NJR)数据,倾向性评分匹配后比较骨关节炎且肩袖完整患者中金属与陶瓷肱骨头假体的翻修率。全肩关节置换中金属头翻修率显著高于陶瓷头(HR 3.31,95%CI 1.67–6.58),8年假体生存率陶瓷98.7% vs 金属96.4%。半肩关节置换中两种假体翻修率无显著差异(HR 1.33,95%CI 0.76–2.34)。
要点
- 全肩关节置换中,金属肱骨头的翻修率显著高于陶瓷肱骨头(HR 3.31,95%CI 1.67–6.58)。
- 8年假体生存率:陶瓷全肩关节置换98.7%(95%CI 97.3–99.4)vs 金属96.4%(95%CI 95.2–97.3)。
- 半肩关节置换中,陶瓷与金属肱骨头的翻修率无显著差异(HR 1.33,95%CI 0.76–2.34)。
核心结论
- 在骨关节炎且肩袖完整的患者中,金属肱骨头全肩关节置换的全因翻修率高于陶瓷肱骨头全肩关节置换。
- 半肩关节置换的翻修率根据承重面材料(金属与陶瓷)无差异。
研究设计与样本
- 基于英国国家关节登记(NJR)的前瞻性数据,该登记收集英格兰、威尔士、北爱尔兰、马恩岛和根西岛的数据。
- NJR肩关节置换记录与医院统计数据和全国死亡登记链接。
- 纳入因骨关节炎且肩袖完整行全肩关节置换或半肩关节置换的患者。
- 金属与陶瓷肱骨头假体在全肩关节置换和半肩关节置换组内分别基于12项和11项特征进行倾向性评分匹配。
- 主要结局为至首次翻修的时间,次要结局为非翻修再手术。
主要发现
- 共纳入4799例全肩关节置换(金属3578例,陶瓷1221例)和1363例半肩关节置换(金属1020例,陶瓷343例)。
- 全肩关节置换中,金属组翻修率高于陶瓷组,风险比(HR)为3.31(95%置信区间1.67至6.58)。
- 8年时,陶瓷全肩关节置换的假体生存率为98.7%(95%CI 97.3至99.4),金属全肩关节置换为96.4%(95%CI 95.2至97.3)。
- 大多数翻修的全肩关节置换原因为肩袖功能不全或不稳定/脱位。
- 陶瓷半肩关节置换与金属半肩关节置换的翻修率无显著差异(HR 1.33,95%CI 0.76至2.34);陶瓷半肩关节置换8年假体生存率为92.8%(95%CI 86.9至96.1),金属半肩关节置换为91.6%(95%CI 89.3至93.5);大多数翻修的半肩关节置换原因为肩袖失效。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. METHODS: NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. RESULTS: A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. CONCLUSION: The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface.
引用
- Davies A, Sabharwal S, Liddle AD, et al. Revision rate in metal compared to ceramic humeral head total shoulder arthroplasty and hemiarthroplasty. Bone Joint J. 2024. PMID: 38688478. doi:10.1302/0301-620X.106B5.BJJ-2023-1093.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。