术中CT扫描的Hounsfield单位与术前值相关吗?

Do Hounsfield Units From Intraoperative CT Scans Correlate With Preoperative Values?
PubMed 文献 · Clin Orthop Relat Res · 2024-05-09

这项回顾性诊断研究纳入81例接受器械辅助脊柱融合术的患者,比较术前与术中CT测量的276对椎体Hounsfield单位。术中Hounsfield单位可由医师可靠测量(相关系数0.82),但与术前值无相关性(r=0.01),两者不可互换使用。

要点

  • 术中CT的椎体Hounsfield单位可由医师可靠测量,两名评估者间相关系数为0.82。
  • 同一椎体术前与术中Hounsfield单位无相关性(r=0.01,p=0.84)。
  • 控制患者与临床因素后,术前与术中Hounsfield单位仍无关系。

核心结论

  • 从术中CT测量Hounsfield单位是可行的,但所得值与术前CT测量值无任何可预测的关系,因此这些值不应互换使用。
  • 未来研究应探索术中Hounsfield单位测量作为独立于术前测量的预后价值。

研究设计与样本

  • 回顾性诊断研究,纳入2015年1月至2022年12月期间因退行性疾病或创伤接受术中CT扫描辅助器械脊柱融合术的患者。
  • 最终纳入81例患者,采集276个术前和276个术中椎体Hounsfield单位测量值,由两名骨科住院医师(PGY3和PGY5)从同一椎体提取数据。
  • 排除标准包括术前180天内无融合节段CT、因感染或转移性疾病手术、既往内固定翻修手术、术中CT在置入器械后获取、术中CT无法测量、既往椎体后凸成形术骨水泥影响测量、术前与术中CT峰值电压不同。
  • 采用双向随机效应绝对一致性组内相关、重复测量相关及以患者为随机效应的线性混合模型进行统计分析。
  • 证据等级为III级,诊断性研究。

主要发现

  • 两名评估者测量10例患者代表性样本的31个椎体,相关系数为0.82(95%CI 0.66至0.91),表明相关性良好。
  • 同一椎体术前与术中测量值重复测量相关分析显示无相关性(r=0.01 [95%CI -0.13至0.15];p=0.84)。
  • 控制年龄、BMI、骨密度调节药物使用、ASA分级、吸烟状态和Charlson合并症指数总分后,术前与术中Hounsfield单位测量值仍无关系。

临床怎么用

  • 作者认为,尽管从术中CT测量Hounsfield数据可行,但所得值与术前研究所得值无任何可预测的关系,因此这些值不应互换使用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is increasing interest in forecasting postoperative complications using bone density metrics. Vertebral Hounsfield unit measurements obtained from CT scans performed for surgical planning or other purposes, known as opportunistic CTs, have shown promise for their ease of measurement and the ability to target density measurement to a particular region of interest. Concomitant with the rising interest in prognostic bone density measurement use has been the increasing adoption of intraoperative advanced imaging techniques. Despite the interest in both outcome prognostication and intraoperative advanced imaging, there is little information regarding the use of CT-based intraoperative imaging as a means to measure bone density. QUESTIONS/PURPOSES: (1) Can vertebral Hounsfield units be reliably measured by physician reviewers from CT scans obtained intraoperatively? (2) Do Hounsfield units measured from intraoperative studies correlate with values measured from preoperative CT scans? METHODS: To be eligible for this retrospective study, patients had to have been treated with the use of an intraoperative CT scan for instrumented spinal fusion for either degenerative conditions or traumatic injuries between January 2015 and December 2022. Importantly, patients without a preoperative CT scan of the fused levels within 180 days before surgery or who were indicated for surgery because of infection, metastatic disease, or who were having revision surgery after prior instrumentation were excluded from the query. Of the 285 patients meeting these inclusion criteria, 53% (151) were initially excluded for the following reasons: 36% (102) had intraoperative CT scans obtained after placement of instrumentation, 16% (47) had undergone intraoperative CT scans but the studies were not accessible for Hounsfield unit measurement, and 0.7% (2) had prior kyphoplasty wherein the cement prevented Hounsfield unit measurement. Finally, an additional 19% (53) of patients were excluded because the preoperative CT and intraoperative CT were obtained at different peak voltages, which can influence Hounsfield unit measurement. This yielded a final population of 81 patients from whom 276 preoperative and 276 intraoperative vertebral Hounsfield unit measurements were taken. Hounsfield unit data were abstracted from the same vertebra(e) from both preoperative and intraoperative studies by two physician reviewers (one PGY3 and one PGY5 orthopaedic surgery resident, both pursuing spine surgery fellowships). For a small, representative subset of patients, measurements were taken by both reviewers. The feasibility and reliability of Hounsfield unit measurement were then assessed with interrater reliability of values measured from the same vertebra by the two different reviewers. To compare Hounsfield unit values from intraoperative CT scans with preoperative CT studies, an intraclass correlation using a two-way random effects, absolute agreement testing technique was employed. Because the data were formatted as multiple measurements from the same vertebra at different times, a repeated measures correlation was used to assess the relationship between preoperative and intraoperative Hounsfield unit values. Finally, a linear mixed model with patients handled as a random effect was used to control for different patient and clinical factors (age, BMI, use of bone density modifying agents, American Society of Anesthesiologists [ASA] classification, smoking status, and total Charlson comorbidity index [CCI] score). RESULTS: We found that Hounsfield units can be reliably measured from intraoperative CT scans by human raters with good concordance. Hounsfield unit measurements of 31 vertebrae from a representative sample of 10 patients, measured by both reviewers, demonstrated a correlation value of 0.82 (95% CI 0.66 to 0.91), indicating good correlation. With regard to the relationship between preoperative and intraoperative measurements of the same vertebra, repeated measures correlation testing demonstrated no correlation between preoperative and intraoperative measurements (r = 0.01 [95% CI -0.13 to 0.15]; p = 0.84). When controlling for patient and clinical factors, we continued to observe no relationship between preoperative and intraoperative Hounsfield unit measurements. CONCLUSION: As intraoperative CT and measurement of vertebral Hounsfield units both become increasingly popular, it would be a natural extension for spine surgeons to try to extract Hounsfield unit data from intraoperative CTs. However, we found that although it is feasible to measure Hounsfield data from intraoperative CT scans, the obtained values do not have any predictable relationship with values obtained from preoperative studies, and thus, these values should not be used interchangeably. With this knowledge, future studies should explore the prognostic value of intraoperative Hounsfield unit measurements as a distinct entity from preoperative measurements. LEVEL OF EVIDENCE: Level III, diagnostic study.