文献速递脊柱外科创伤骨科骨质疏松与代谢性骨病

不同后路固定技术对骨质疏松性胸腰椎爆裂骨折稳定性和相邻节段退变生物力学效应的有限元分析

Biomechanical Effect of Different Posterior Fixation Techniques on Stability and Adjacent Segment Degeneration in Treating Thoracolumbar Burst Fracture With Osteoporosis: A Finite Element Analysis.
PubMed 文献 · Spine (Phila Pa 1976) · 2024-05-09

本研究采用有限元分析构建T10-L5三维模型,模拟骨质疏松性L1爆裂骨折,比较四种后路固定技术。结果显示长节段椎弓根螺钉固定(LSPS)稳定性最高但相邻椎间盘和关节突应力较大,皮质骨螺钉固定(CBT)稳定性最小,骨水泥强化椎弓根螺钉固定(CAPS)与CBT-PS在提供中等固定强度的同时降低相邻结构应力。

要点

  • LSPS组整体活动度最小(1.25°),骨折椎体活动度占比最低(75.04%),稳定性最高。
  • CBT组整体活动度最大(1.86°),相邻节段活动度最大(1.32°),稳定性最小。
  • LSPS组相邻椎间盘最大应力(9.60 MPa)和关节突最大应力(3.36 MPa)较大,相邻节段退变风险增加。

核心结论

  • LSPS提供最大稳定性,CBT提供最小稳定性,但LSPS固定后相邻椎间盘和关节突应力升高增加相邻节段退变可能性。
  • CAPS和CBT-PS在提供中等固定强度的同时降低椎间盘和关节突应力,显示出显著的生物力学优势。

研究设计与样本

  • 研究设计为有限元分析。
  • 将CT扫描图像导入MIMICS并由Geomagic处理,构建T10-L5区域三维模型。
  • 在L1椎体行V形截骨模拟骨质疏松性爆裂骨折,使用SolidWorks软件设计四种固定技术。

主要发现

  • CBT组整体活动度最高为1.86°,LSPS组最低为1.25°。
  • LSPS组骨折椎体活动度占固定节段百分比最小为75.04%,提示固定后稳定性最高。
  • CBT组相邻节段最大活动度最大为1.32°,LSPS组最小为0.89°。
  • LSPS组相邻椎间盘最大应力为9.60 MPa,关节突最大应力为3.36 MPa,提示相邻节段疾病风险增加。

临床怎么用

  • LSPS提供最大稳定性但增加相邻椎间盘和关节突应力,可能增加相邻节段退变可能性。
  • CBT提供最小稳定性,相邻节段活动度最大。
  • CAPS和CBT-PS在提供中等固定强度的同时降低椎间盘和关节突应力,显示出显著生物力学优势。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Finite element analysis. OBJECTIVE: To investigate the biomechanical effect of four posterior fixation techniques on stability and adjacent segment degeneration in treating thoracolumbar burst fractures with osteoporosis. SUMMARY OF BACKGROUND DATA: In terms of stability and adjacent segment degeneration, there remains no consensus or guidelines on the optimal technique for the treatment of thoracolumbar burst fractures in patients with osteoporosis. MATERIALS AND METHODS: Images of CT scans were imported into MIMICS and further processed by Geomagic to build three-dimensional models of the T10-L5 region. A v-shaped osteotomy was performed on the L1 vertebral body to simulate a burst fracture in the setting of osteoporosis. Subsequently, four fixation techniques were designed using SolidWorks software. Range of motion (ROM) of the global spine, ROM distribution, ROM of adjacent segment, Von Mises stress on adjacent intervertebral disks, and facet joints were analyzed. RESULTS: Among the four groups, the cortical bone screw fixation (CBT) showed the highest global ROM at 1.86°, while long-segmented pedicle screw fixation (LSPS) had the lowest global ROM at 1.25°. The LSPS had the smallest percentage of ROM of fractured vertebral body to fixed segment at 75.04%, suggesting the highest stability after fixation. The maximum ROM of the adjacent segment was observed in the CBT at 1.32°, while the LSPS exhibited the smallest at 0.89°. However, the LSPS group experienced larger maximum stress on the adjacent intervertebral disks (9.60 MPa) and facet joints (3.36 MPa), indicating an increasing risk of adjacent segment disease. CONCLUSION: LSPS provided the greatest stability, while CBT provided the smallest amount of stability. However, the elevated stress on adjacent intervertebral disks and facet joints after LSPS fixation increased the possibility of adjacent segment degeneration. Cement-augmented pedicle screw fixation (CAPS) and combined cortical bone screw and pedicle screw fixation (CBT-PS) demonstrated significant biomechanical advantages in providing moderate fixation strength while reducing stress on the intervertebral disks and facet joints.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Zhang G, Li J, Zhang L, et al. Biomechanical Effect of Different Posterior Fixation Techniques on Stability and Adjacent Segment Degeneration in Treating Thoracolumbar Burst Fracture With Osteoporosis: A Finite Element Analysis. Spine (Phila Pa 1976). 2024. PMID: 38721831. doi:10.1097/BRS.0000000000005034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。