文献速递关节外科创伤骨科

使用模块化带沟槽锥形翻修股骨柄与交锁螺钉对温哥华B3型假体周围骨折伴峡部骨量不足行翻修全髋关节置换术

Revision total hip arthroplasty using a modular fluted, tapered revision femoral component and interlocking screws in Vancouver B3 periprosthetic fractures with insufficient bone at the isthmus.
PubMed 文献 · Bone Joint J · 2024-04-01

本研究前瞻性随访46例温哥华B3型假体周围骨折(Paprosky IIIA型23例、IIIB型19例、IV型4例)患者,采用模块化锥形非骨水泥翻修股骨柄联合远端锥套锥固定,其中23例因峡部固定<3 cm加用远端交锁螺钉。平均随访48.8个月,骨折骨性愈合43例(93.5%),柄骨长入42例(91.3%),Harris髋关节评分从术后3个月57.8分升至24个月76.1分,作者认为该方案可重复获得良好结果。

要点

  • 46例温哥华B3型骨折中,43例(93.5%)在6个月时骨折及骨瓣达到骨性愈合。
  • 42例(91.3%)股骨柄获得骨长入,4例为稳定纤维固定,1例出现非进展性下沉。
  • Harris髋关节评分从术后3个月57.8分升至术后24个月76.1分。

核心结论

  • 采用2°锥形带沟槽翻修股骨柄联合远端锥套锥固定,并在峡部骨缺损患者中加用远端交锁螺钉,在温哥华B3型骨折伴Paprosky IIIA、IIIB和IV型缺损患者中,就骨折愈合、股骨柄下沉或松动及临床结局而言,可重复地获得良好结果。

研究设计与样本

  • 前瞻性随访46例温哥华B3型骨折患者的46个股骨柄,其中Paprosky IIIA型23例、IIIB型19例、IV型4例,平均年龄80.4岁(66至100岁)。
  • 采用经股骨入路,使用模块化、锥形、非骨水泥翻修Revitan弯曲股骨柄,远端锥套锥固定,平均随访48.8个月(标准差23.9;24至112个月)。
  • 23例因远端锥套锥固定于峡部的长度<3 cm而加用远端交锁螺钉。

主要发现

  • 术后第一年内1例患者(2.2%)死亡。
  • 术后6个月,43例患者(93.5%)骨折及骨瓣为骨性愈合,3例为纤维性愈合;42例(91.3%)股骨柄为骨长入,4例为稳定纤维固定。
  • 无患者出现交锁螺钉周围放射透亮线,无螺钉断裂;1例出现非进展性下沉,2例发生脱位。
  • Harris髋关节评分从术后3个月的平均57.8分(标准差7.9)升至术后24个月的平均76.1分(标准差10.7)。

临床怎么用

  • 作者认为,对于温哥华B3型骨折伴Paprosky IIIA、IIIB和IV型缺损的患者,使用2°锥形带沟槽翻修股骨柄联合远端锥套锥固定,并在峡部骨缺损时加用远端交锁螺钉,可重复地获得良好的骨折愈合、股骨柄稳定性及临床结局。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients. METHODS: A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm. RESULTS: One patient (2.2%) died during the first postoperative year. After six months, 43 patients (93.5%) had osseous, and three had fibrous consolidation of the fracture and the bony flap, 42 (91.3%) had bony ingrowth and four had stable fibrous fixation of the stem. No patient had radiolucency around the interlocking screws and no screw broke. One patient had non-progressive subsidence and two had a dislocation. The mean Harris Hip Score increased from of 57.8 points (SD 7.9) three months postoperatively to 76.1 points (SD 10.7) 24 months postoperatively. CONCLUSION: The 2° tapered, fluted revision femoral component with distal cone-in-cone-fixation, combined with additional distal interlocking in patients with bony deficiency at the isthmus, led to reproducibly good results in patients with a Vancouver B3 fracture and Paprosky type IIIA, IIIB, and IV defects with regard to union of the fracture, subsidence or loosening of the stem, and clinical outcomes.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Fink B, Ahmadian A, Sax FH, et al. Revision total hip arthroplasty using a modular fluted, tapered revision femoral component and interlocking screws in Vancouver B3 periprosthetic fractures with insufficient bone at the isthmus. Bone Joint J. 2024. PMID: 38555949. doi:10.1302/0301-620X.106B4.BJJ-2023-0899.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。