商业滑液抗原检测在翻修全膝关节置换术患者假体周围关节感染诊断中劣于传统培养
这项多中心回顾性研究纳入526例翻修全膝关节置换术患者,以2018年国际共识会议(ICM)标准定义假体周围关节感染(PJI),比较滑液微生物鉴定(MID)抗原检测与培养的诊断准确性。培养的AUC为0.864,MID检测为0.802,培养显著更高(P=0.037);MID检测敏感性较低(61.6%),且在培养阳性PJI中与培养不一致率高(29.7%)。结论认为滑液抗原检测相比传统培养未提供额外临床获益。
要点
- 培养诊断PJI的AUC为0.864,显著高于MID抗原检测的0.802(P=0.037)。
- MID抗原检测敏感性61.6%、特异性98.8%,培养敏感性75.2%、特异性97.5%。
- MID检测在41.9%的培养阴性PJI病例中呈阳性,培养与MID均阳性时不一致率达29.7%。
核心结论
- 滑液抗原检测在PJI诊断中相比传统培养未提供额外临床获益,敏感性低且与培养不一致率较高。
研究设计与样本
- 多中心回顾性研究,纳入613例翻修全膝关节置换术患者,排除抽吸至翻修超过180天者62例、初次置换术后90天内就诊者17例及ICM评分不确定者8例,最终分析526例。
- 以2018年ICM标准定义PJI,采用受试者工作特征曲线分析比较MID抗原检测与任何阳性培养(术前或术中)的诊断效能。
主要发现
- 526例中ICM阳性125例(23.8%),ICM阴性401例(76.2%)。
- 培养的AUC为0.864,敏感性75.2%,特异性97.5%。
- MID检测的AUC为0.802,敏感性61.6%,特异性98.8%。
- 培养的AUC显著高于MID检测(P=0.037)。
- MID检测在41.9%的培养阴性PJI病例中呈阳性;ICM阳性组中培养与MID均阳性时不一致率为29.7%。
关键数值与推荐
- PJI定义采用2018年ICM标准。
- 培养诊断PJI的AUC为0.864,敏感性75.2%,特异性97.5%。
- MID抗原检测诊断PJI的AUC为0.802,敏感性61.6%,特异性98.8%。
- 培养与MID检测AUC比较P=0.037。
- 证据等级为Level III。
临床怎么用
- 原文结论认为滑液抗原检测相比传统培养在PJI诊断中未提供额外临床获益。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Despite its limitations, a culture remains the "gold standard" for pathogen identification in patients who have periprosthetic joint infection (PJI). Recently, a synovial fluid antigen test has been introduced by a commercial entity. The purpose of this multicenter study was to determine the accuracy of the antigen test in the diagnosis of PJI. METHODS: This retrospective study identified 613 patients undergoing revision total knee arthroplasty who had undergone preoperative synovial fluid analysis. A PJI was defined using the 2018 International Consensus Meeting (ICM) criteria. Patients who had an extended period (> 180 days) from aspiration to revision procedure (n = 62), those presenting within 90 days of their index arthroplasty procedure (n = 17), and patients who had an inconclusive ICM score (n = 8) were excluded. Using receiver operator characteristic curve analyses, we examined the utility of the microbial identification (MID) antigen test and any positive culture (either preoperative or intraoperative) in the diagnosis of PJI. RESULTS: A total of 526 patients were included. Of these, 125 (23.8%) were ICM positive and 401 (76.2%) were ICM negative. Culture demonstrated an area under the curve (AUC) of 0.864, sensitivity of 75.2%, and specificity of 97.5%. On the other hand, the MID test exhibited an AUC of 0.802, sensitivity of 61.6%, and specificity of 98.8%. The AUC of culture was significantly higher than that of the MID test (P = .037). The MID test was positive in 41.9% of culture-negative PJI cases. We also observed a high rate of discordance (29.7%) when both culture and the MID test were positive in the ICM-positive group. CONCLUSIONS: Synovial fluid antigen testing does not provide additional clinical benefit when compared to traditional cultures for the diagnosis of PJI. The antigen test had low sensitivity in the diagnosis of PJI and a relatively high rate of discordance with culture. LEVEL OF EVIDENCE: Level III.
引用
- Tarabichi S, Johnson RM, Quinlan ND, et al. Commercial Synovial Antigen Testing is Inferior to Traditional Culture for the Diagnosis of Periprosthetic Joint Infection in Patients Undergoing Revision Total Knee Arthroplasty. J Arthroplasty. 2024. PMID: 38599530. doi:10.1016/j.arth.2024.03.067
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。