本研究在大型医疗中心实施基于科室的综合安全计划(CUSP)以改善全膝和全髋关节置换术的质量与效率,采用回顾性比较分析。实施后首台手术准时开始率从43%升至81%,首台延迟、手术时长、患者入室准备、手术操作、患者离室及房间周转的中位时间均显著下降,但麻醉准备时间无显著变化。结论认为CUSP在几乎所有效率指标上带来显著改善并预防了患者安全失误。

要点

  • CUSP实施后首台手术准时开始率从43%升至81%。
  • 首台延迟、手术时长、入室准备、操作、离室及房间周转中位时间显著下降。
  • 麻醉准备时间无显著变化。

核心结论

  • 对全膝和全髋关节置换术实施CUSP关节置换项目后,几乎所有效率指标均显著改善,并预防了患者安全失误。
  • 作者认为这些结果体现了CUSP作为一种质量改进方法在大型医疗中心关节置换服务中维持患者安全与围手术期效率的通用性。

研究设计与样本

  • 回顾性比较研究,证据等级III。
  • 本机构实施基于科室的综合安全计划(CUSP),与临床和行政团队及5个干预驱动工作组广泛合作。
  • 分析CUSP实施后首台手术准时开始率、首台延迟时长、手术时长、麻醉准备、患者入室准备、手术操作、患者离室及房间周转,采用独立样本中位数检验、Mann-Whitney U检验和百分点差异计算。

主要发现

  • CUSP关节置换项目实施后,首台手术准时开始率从43%升至81%。
  • 全膝和全髋关节置换术的首台延迟、手术时长、患者入室准备、手术操作、患者离室及房间周转中位时间均观察到统计学显著下降。
  • 麻醉准备中位时间未观察到统计学显著下降。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The complexity of health care delivery systems presents a unique challenge for the perioperative space. In the area of arthroplasty procedures, the shift of complex patients into ambulatory surgery centers and reimbursement that is no longer commensurate with the inflated costs of performing these procedures have created difficulties for hospitals and physicians alike. Thus, there is a critical need to optimize perioperative workflows while maintaining high-quality care provision. METHODS: Our institution implemented the Comprehensive Unit-based Safety Program (CUSP) to improve the quality and efficiency of total knee and hip arthroplasties (TKAs and THAs). This initiative involved extensive collaboration with clinical and administrative teams, as well as 5 intervention-driven workgroups. First-case on-time start rates and duration of first-case delays, case length, anesthesia preparation, in-room patient preparation, operation, patient exit, and room turnover after CUSP implementation were analyzed using independent samples median testing, Mann-Whitney U testing, and a percentage-point difference calculation. RESULTS: After CUSP arthroplasty implementation, first-case on-time start rates increased from 43 to 81%. Statistically significant decreases were observed in median times for first-case delays, case length, in-room patient preparation, operation, patient exit, and room turnover for TKAs and THAs, but not anesthesia preparation. CONCLUSIONS: The implementation of CUSP arthroplasty for TKAs and THAs resulted in significant improvements in nearly all efficiency metrics, as well as preventions of patient safety missteps. These results exemplify the versatility of CUSP as a quality improvement method that can maintain patient safety and perioperative efficiency in the arthroplasty service of a large-scale medical center. LEVEL OF EVIDENCE: III.