文献速递关节外科

初次全髋关节置换术中32毫米和36毫米股骨头较28毫米股骨头翻修风险更低:一项单中心10,104髋比较研究

Lower Risk of Revision With 32- and 36-Millimeter Femoral Heads Compared With 28-mm Heads in Primary Total Hip Arthroplasty: A Comparative Single-Center Study (10,104 Hips).
PubMed 文献 · J Arthroplasty · 2023-10-30

该单中心回顾性连续研究纳入2003至2019年10,104例初次全髋关节置换术,比较28、32、36毫米股骨头的翻修结局,平均随访6年。32毫米和36毫米股骨头全因翻修风险低于28毫米,32毫米组差异有统计学意义(P=0.01);32毫米和36毫米组脱位翻修风险均显著降低(均P=0.03);排除脱位的全因翻修无显著差异。

要点

  • 32毫米股骨头全因翻修风险较28毫米显著降低(P=0.01),36毫米组也呈降低趋势。
  • 32毫米和36毫米股骨头脱位翻修风险均较28毫米显著降低(均P=0.03)。
  • 排除脱位后全因翻修在各尺寸间无显著差异,大尺寸头未增加早期翻修风险。

核心结论

  • 32毫米和36毫米股骨头较28毫米全因翻修风险降低,32毫米组差异有统计学意义(P=0.01)。
  • 32毫米和36毫米股骨头脱位翻修风险较28毫米均显著降低(均P=0.03)。
  • 排除脱位后全因翻修在各尺寸间无显著差异。
  • 在本10,104例、随访至17年的队列中,大尺寸股骨头增加无菌性松动、聚乙烯磨损或锥度腐蚀所致早期翻修的担忧似乎没有依据。

研究设计与样本

  • 单中心回顾性连续研究,纳入2003至2019年在本机构行初次全髋关节置换术的10,104髋。
  • 平均随访6年(范围1至17.5年),中位年龄69岁(范围13至101岁),女性占61.5%。
  • 后路入路占71.6%;28毫米股骨头3,295髋(32.6%),32毫米4,858髋(48.1%),36毫米1,951髋(19.3%)。
  • 采用Kaplan-Meier生存曲线估计翻修时间,Cox比例风险回归比较各组翻修率,并调整手术年龄、性别、主要诊断、美国麻醉医师协会评分、摩擦界面类型和固定方式。

主要发现

  • 总体翻修率为1.7%,36毫米组最低(28毫米组2.7% vs 32毫米组1.3% vs 36毫米组1.1%)。
  • Cox回归显示32毫米和36毫米股骨头全因翻修风险较28毫米降低,32毫米组差异有统计学意义(P=0.01)。
  • 32毫米组(P=0.03)和36毫米组(P=0.03)脱位翻修风险均较28毫米显著降低。
  • 排除脱位的全因翻修分析显示各股骨头尺寸间无显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We aimed to compare the clinical outcomes of different head sizes (28-, 32-, and 36- millimeter) in primary total hip arthroplasty (THA) at mean 6 years follow-up (range, 1 to 17.5 years). METHODS: This was a retrospective consecutive study of primary THA at our institution (2003 to 2019). Demographic and surgical data were collected. The primary outcome measures were all-cause revision, revision for dislocation, and all-cause revision excluding dislocation. Continuous descriptive statistics used means, median values, ranges, and 95% confidence intervals, where appropriate. Kaplan-Meier survival curves were used to estimate time to revision. Cox proportional hazard regression analyses were used to compare revision rates between the femoral head size groups. Adjustments were made for age at surgery, sex, primary diagnosis, American Society of Anesthesiologists score, articulation type, and fixation methods. There were 10,104 primary THAs included; median age was 69 years (range, 13 to 101) with 61.5% women. A posterior approach was performed in 71.6%. There were 3,295 hips with 28-mm heads (32.6%), 4,858 (48.1%) with 32-mm heads, and 1,951 (19.3%) with 36-mm heads. RESULTS: Overall rate of revision was 1.7% with the lowest rate recorded for the 36-mm group (2.7 versus 1.3 versus 1.1%). Cox regression analyses showed a decreased risk of all-cause revision for 32 and 36-mm head sizes as compared to 28-mm; this was statistically significant for the 32-mm group (P = .01). Risk of revision for dislocation was significantly reduced in both 32-mm (P = .03) and 36-mm (P = .03) head sizes. Analysis of all cause revision excluding dislocation showed no significant differences between head sizes. CONCLUSIONS: We found a significantly reduced risk of revision for all causes, but particularly revision for dislocation with larger head sizes. Concerns regarding increased risk of early revision for aseptic loosening, polyethylene wear, or taper corrosion with larger heads appear to be unfounded in this cohort of 10,104 patients with up to 17 years follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Matar HE, van Duren BH, Bloch BV, et al. Lower Risk of Revision With 32- and 36-Millimeter Femoral Heads Compared With 28-mm Heads in Primary Total Hip Arthroplasty: A Comparative Single-Center Study (10,104 Hips). J Arthroplasty. 2023. PMID: 38661490. doi:10.1016/j.arth.2023.10.042

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。