文献速递关节外科小儿骨科创伤骨科

非骨水泥全髋关节置换联合Paavilainen股骨短缩截骨术在Crowe IV型发育性髋关节发育不良患者中10年可获得良好结果

Cementless Total Hip Arthroplasty With Paavilainen Femoral Shortening Osteotomy Can Provide Good Results at 10 Years in Patients Who Have Crowe IV Developmental Dysplasia of the Hip.
PubMed 文献 · J Arthroplasty · 2024-04-12

该回顾性研究分析335例Crowe IV型发育性髋关节发育不良患者采用Paavilainen技术行初次全髋关节置换,平均随访10.2年。最常见翻修原因为大转子远端推进处骨不连(22髋,6.5%),10年假体生存率以无菌性松动为终点髋臼侧97.3%、股骨侧98.7%,以任何原因再手术为终点85.9%。近端股骨骨块与远端股骨外侧接触长度小于35 mm时骨不连更常见,作者认为可能需要辅助固定。

要点

  • Paavilainen股骨短缩截骨术联合非骨水泥全髋关节置换术后10年临床与影像学结果良好。
  • 大转子远端推进处骨不连是最常见翻修原因,发生率为6.5%(22髋)。
  • 截骨后骨块接触长度小于35 mm时骨不连风险高,作者认为可能需要辅助固定。

核心结论

  • 非骨水泥初次全髋关节置换采用Paavilainen股骨短缩截骨术治疗Crowe IV型发育性髋关节发育不良可获得良好的临床和影像学术后结果。
  • 若截骨后骨块间接触长度小于35 mm,骨不连风险高,作者认为可能需要辅助固定。

研究设计与样本

  • 回顾性分析335髋采用Paavilainen技术行初次全髋关节置换的病例,平均随访10.2年。

主要发现

  • 最常见翻修原因为大转子远端推进处骨不连,见于22髋(6.5%)。
  • 10年生存率以无菌性松动为终点:髋臼组件97.3%,股骨组件98.7%;以任何原因再手术为终点为85.9%。
  • 患者功能结果改善,平均肢体延长27.8 mm。
  • 近端股骨骨块与远端股骨外侧表面接触长度小于35 mm时骨不连更常见。

关键数值与推荐

  • 骨不连风险相关阈值:近端股骨骨块与远端股骨外侧表面接触长度小于35 mm。
  • 10年假体生存率:髋臼组件97.3%(以无菌性松动为终点),股骨组件98.7%(以无菌性松动为终点),85.9%(以任何原因再手术为终点)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study was to present the clinical and radiologic results of primary total hip arthroplasty (THA) using the femoral shortening osteotomy technique described by Paavilainen in patients who have Crowe IV developmental dysplasia of the hip. METHODS: We retrospectively analyzed the results of primary THA using the Paavilainen technique in 335 hips. The mean follow-up was 10.2 years. The degree of limp, leg-length discrepancy, and patient satisfaction were assessed. The Oxford Hip Score was used to examine functional outcomes. A number of radiographic parameters were also assessed. RESULTS: The most common reason for revision surgery was nonunion of the distally advanced greater trochanter. This complication was observed in 22 hips (6.5%). The 10-year survival for acetabular components, it was 97.3%, and for femoral components was 98.7% with aseptic loosening as the end point, and 85.9% with reoperation for any reason as the end point. Patients demonstrated improved functional outcomes. The mean limb lengthening was 27.8 mm. Nonunion was more common if the contact length of the proximal femoral fragment with the lateral surface of the distal femoral fragment was less than 35 mm. CONCLUSIONS: Cementless primary THA using the femoral shortening osteotomy technique described by Paavilainen in patients who have Crowe IV dysplasia of the hip demonstrates good clinical and radiologic postoperative results. If the contact between the fragments after osteotomy is less than 35 mm, there is a high risk of nonunion, and supplemental fixation may be warranted.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tikhilov RM, Dzhavadov AA, Ziganshin DR, et al. Cementless Total Hip Arthroplasty With Paavilainen Femoral Shortening Osteotomy Can Provide Good Results at 10 Years in Patients Who Have Crowe IV Developmental Dysplasia of the Hip. J Arthroplasty. 2024. PMID: 38614357. doi:10.1016/j.arth.2024.04.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。