文献速递关节外科

CCJR Gerard A. Engh 卓越膝关节研究奖:全膝关节置换术后睡眠障碍的远程监测——一项警示性说明

The CCJR® Gerard A. Engh Excellence in Knee Research Award: Remote Monitoring of Sleep Disturbance Following Total Knee Arthroplasty: A Cautionary Note.
PubMed 文献 · J Arthroplasty · 2024-04-08

研究连续纳入110例初次全膝关节置换术患者,术前及术后90天使用可穿戴设备追踪五项经验证的睡眠指标,并与患者自报睡眠质量进行相关性分析。结果显示患者自报睡眠质量术后初期恶化,至90天恢复至术前水平;术后30天仅卧床时间、睡眠时间和快速眼动睡眠分钟数与自报睡眠质量弱相关,60天和90天无任何相关性。作者提醒使用远程监测的医生注意设备生成的替代指标可能与患者报告结局仅弱相关甚至不相关。

要点

  • 自报睡眠质量差的比例从术前20.8%升至术后30天44.4%,术后60天降至26.5%,90天降至20.2%。
  • 术后30天卧床时间、睡眠时间、快速眼动睡眠分钟数与自报睡眠质量弱相关(相关系数分别为0.356、0.345、0.345,P<.001)。
  • 术后60天和90天可穿戴设备指标与自报睡眠质量均无相关性。

核心结论

  • 全膝关节置换术后患者自报睡眠质量初期恶化,至90天恢复至术前水平。
  • 术后30天仅卧床时间、睡眠时间和快速眼动睡眠分钟数与自报睡眠质量弱相关,60天和90天未检测到任何相关性。
  • 作者提醒使用远程监测的医生,设备生成的替代指标可能与所研究参数的患者报告结局仅弱相关甚至不相关。

研究设计与样本

  • 连续纳入接受初次全膝关节置换术的患者,共110例。
  • 患者术前及术后90天使用可穿戴设备追踪五项经验证的睡眠指标,每月评估自报睡眠质量。
  • 采用点二列相关检验分析可穿戴睡眠数据与自报睡眠质量的相关性,分类数据采用卡方检验比较。

主要发现

  • 术前20.8%的患者报告睡眠「相当差」或「非常差」,术后30天增至44.4%,术后60天降至26.5%,术后90天降至20.2%。
  • 术后30天,卧床时间、睡眠时间和快速眼动睡眠分钟数与自报睡眠质量弱相关(相关系数分别为0.356、0.345、0.345,P<.001)。
  • 术后60天和90天,自报睡眠质量与可穿戴设备收集的任何指标均无相关性。

临床怎么用

  • 作者提醒使用远程监测的医生,设备生成的替代指标可能与所研究参数的患者报告结局仅弱相关甚至不相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Sleep disturbances are common after total knee arthroplasty (TKA). Despite the rising popularity of wearables to track sleep, little evidence exists in the arthroplasty literature regarding their efficacy. We aimed to correlate validated wearable sleep metrics with patient-reported sleep quality following TKA. METHODS: Patients undergoing primary TKA were consecutively enrolled. Patients used a wearable device preoperatively and 90 days postoperatively to track five previously-validated measures of sleep. Each month, they rated their sleep quality. Wearable sleep data was correlated with patient-reported sleep quality using a point biserial correlation test. Categorical data were compared using Chi-square tests. A total of 110 patients were included. RESULTS: Preoperatively, 20.8% of patients reported "fairly bad" or "very bad" sleep; this increased to 44.4% 30 days postoperatively, then decreased to 26.5% 60 days postoperatively, and to 20.2% 90 days postoperatively. At 30 days postoperatively, time in bed, time asleep, and minutes of rapid eye movement sleep weakly correlated with patient-reported sleep quality (correlations 0.356, 0.345, and 0.345, respectively; P < .001). Sleep quality did not correlate with any wearable metric collected 60 or 90 days postoperatively. CONCLUSIONS: Patient-reported sleep quality following TKA initially worsened postoperatively, then improved to preoperative levels by 90 days. Time in bed, time asleep, and rapid eye movement sleep minutes only weakly correlated with patient-reported sleep quality at 30 days; no other correlations were detected. Surgeons that utilize remote monitoring following TKA should be aware that surrogate measures generated from these devices may correlate weakly, if at all, with the patient-reported outcome of the parameter being studied.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Gibian JT, Bartosiak KA, Riegler V, et al. The CCJR® Gerard A. Engh Excellence in Knee Research Award: Remote Monitoring of Sleep Disturbance Following Total Knee Arthroplasty: A Cautionary Note. J Arthroplasty. 2024. PMID: 38599526. doi:10.1016/j.arth.2024.03.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。