全膝关节置换术后不稳行单纯聚乙烯衬垫更换与全组件翻修的临床结局比较
本研究回顾280例因全膝关节置换术后不稳行翻修术的膝关节,其中181膝行单纯聚乙烯衬垫更换(IPE)、99膝行全组件翻修,平均随访32.8个月。全组件翻修组2年(99% vs 92%,P=0.024)和5年(94% vs 84%,P=0.024)不稳生存率显著更高,且1年疼痛缓解(P=0.006)和2年膝关节损伤与骨关节炎结局评分(KOOS)改善(P=0.017)更优。作者结论认为IPE不如全组件翻修可靠耐久。
要点
- 全组件翻修组2年不稳生存率99% vs IPE组92%(P=0.024),5年94% vs 84%(P=0.024)。
- 全组件翻修组1年疼痛缓解(P=0.006)和2年KOOS评分改善(P=0.017)优于IPE组。
- 男性与IPE术后复发不稳风险升高相关(HR 3.3,95%CI 1.0–10.6)。
核心结论
- 作者结论认为,对于全膝关节置换术后不稳,单纯聚乙烯衬垫更换不如全组件翻修可靠和耐久。
- 作者认为这些手术应仅保留用于侧副韧带功能完好且组件位置、偏移和旋转均已优化的情况。
研究设计与样本
- 回顾性比较研究,纳入280例因全膝关节置换术后不稳行翻修术的膝关节。
- 181膝行单纯聚乙烯衬垫更换(IPE),99膝行全组件翻修,平均随访32.8个月(范围24.8至82.5个月)。
- 比较患者人口学特征、影像学参数、假体限制类型、因不稳再手术情况及患者报告结局。
主要发现
- 全组件翻修组2年不稳生存率99% vs IPE组92%(P=0.024),5年94% vs 84%(P=0.024)。
- 术后6周、1年和2年时,两组膝关节损伤与骨关节炎结局评分(KOOS)关节置换版和退伍军人RAND 12躯体成分评分无差异。
- 全组件翻修组1年疼痛缓解优于IPE组(P=0.006),1年退伍军人RAND 12躯体成分评分改善优于IPE组(P=0.027),2年KOOS评分改善优于IPE组(P=0.017)。
- 男性与IPE术后复发不稳风险升高相关(HR 3.3,95%CI 1.0至10.6)。
临床怎么用
- 作者认为,单纯聚乙烯衬垫更换用于全膝关节置换术后不稳不如全组件翻修可靠耐久。
- 作者认为,这些手术应仅保留用于侧副韧带功能完好且组件位置、偏移和旋转均已优化的情况。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Instability following total knee arthroplasty (TKA) is a common cause for revision. Isolated polyethylene exchange (IPE) can be performed to increase knee joint stability, but results have been mixed. The purpose of this study was to compare the survivorship and patient-reported outcomes of patients undergoing revision TKA for instability with IPE versus full component revision. METHODS: We reviewed 280 primary TKAs undergoing revision TKA for instability. There were 181 knees that underwent revision with IPE, compared to 99 knees treated with full component revision. The mean follow-up was 32.8 months (range, 24.8 to 82.5). Patient demographics, radiographic parameters, prosthesis constraints, reoperations for instability, and patient-reported outcomes were compared. RESULTS: The survivorship for instability was significantly higher at 2 years (99 versus 92%, P = .024) and 5 years (94 versus 84%, P = .024) for patients undergoing full component revision. Although there was no difference in Knee Injury and Osteoarthritis Outcome Score for Joint Replacements and Veterans RAND 12 physical component scores between the 2 groups at 6 weeks, 1 year, and 2 years after surgery, full revision patients reported greater pain relief (P = .006) and greater improvements in Veterans RAND 12 physical component scores (P = .027) at 1 year and Knee Injury and Osteoarthritis Outcome Score for Joint Replacements scores at 2 years (P = .017) compared to IPE patients. Men were associated with an increased risk for recurrent instability following IPE (hazard ratio 3.3, 95% confidence interval: [1.0 to 10.6]). CONCLUSIONS: Isolated polyethylene exchange was not as reliable or durable compared to full component revision for the management of postoperative instability. These procedures should only be reserved in cases with competent collaterals and when component position, offset, and rotation are optimized.
引用
- Cheng R, Debbi EM, Chalmers BP, et al. Clinical Outcomes of Isolated Polyethylene Exchange Versus Full Component Revision for the Management of Instability Following Total Knee Arthroplasty. J Arthroplasty. 2024. PMID: 38631514. doi:10.1016/j.arth.2024.04.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。