AAHKS手术技术与技术奖:下位螺钉固定降低翻修全髋关节置换术后髋臼部件失败率
本研究回顾三个机构2001至2021年间250例Paprosky II或III型髋臼骨缺损的翻修全髋关节置换术患者,比较下位螺钉固定与仅上位螺钉固定对髋臼部件无菌性再翻修的影响。
要点
- 下位螺钉固定组髋臼再翻修率2.1%,仅上位螺钉固定组11.8%,差异有统计学意义(P=0.0030)。
- 所有下位螺钉固定患者均无神经血管并发症,作者认为该技术安全可靠。
核心结论
- 下位螺钉固定是减少严重髋臼骨缺损患者翻修全髋关节置换术后髋臼部件失败的安全可靠技术。
研究设计与样本
- 回顾性研究,纳入三个机构2001至2021年间250例Paprosky II或III型髋臼骨缺损行髋臼翻修的患者。
- 记录人口学因素、螺钉数量、螺钉位置(上位vs下位)、垫块和/或杯笼结构使用、Paprosky分型及骨盆不连续情况。
- 采用多因素回归分析下位螺钉固定对髋臼部件无菌性再翻修这一主要结局的独立效应。
主要发现
- 平均随访53.4个月(范围12至261个月),16例患者(6.4%)因髋臼松动需再翻修。
- 140例患者(56.0%)接受下位螺钉固定,所有患者螺钉置入过程中均无神经血管并发症。
- 下位螺钉固定组髋臼再翻修率2.1%,仅上位螺钉固定组11.8%,差异有统计学意义(P=0.0030)。
- 未发现其他危险因素。
关键数值与推荐
- 下位螺钉固定组髋臼再翻修率2.1%,仅上位螺钉固定组11.8%(P=0.0030)。
临床怎么用
- 作者认为,在严重髋臼骨缺损的翻修全髋关节置换术中,下位螺钉固定是减少髋臼部件失败的安全可靠技术。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Adjunctive screw fixation has been shown to be reliable in achieving acetabular component stability in revision total hip arthroplasty (THA). The purpose of this study was to assess the effect of inferior screw placement on acetabular component failure following revision THA. We hypothesized that inferior screw fixation would decrease acetabular failure rates. METHODS: We reviewed 250 patients who had Paprosky Type II or III defects who underwent acetabular revision between 2001 and 2021 across three institutions. Demographic factors, the number of screws, location of screw placement (superior versus inferior), use of augments and/or cup-cage constructs, Paprosky classification, and presence of discontinuity were documented. Multivariate regression was performed to identify the independent effect of inferior screw fixation on the primary outcome of aseptic rerevision of the acetabular component. RESULTS: At a mean follow-up of 53.4 months (range, 12 to 261), 16 patients (6.4%) required re-revision for acetabular loosening. There were 140 patients (56.0%) who had inferior screw fixation, all of whom did not have neurovascular complications during screw placement. Patients who had inferior screws had a lower rate of acetabular rerevision than those who only had superior screw fixation (2.1 versus 11.8%, P = .0030). Multivariate regression demonstrates that inferior screw fixation decreased the likelihood of rerevision for acetabular loosening when compared to superior screw fixation alone (odds ratio: 0.1, confidence interval: 0.03 to 0.5; P = .0071). No other risk factors were identified. CONCLUSIONS: Inferior screw fixation is a safe and reliable technique to reduce acetabular component failure following revision THA in cases of severe acetabular bone loss.
引用
- Blackburn AZ, Mittal A, Velasco B, et al. AAHKS Surgical Techniques & Technologies Award: Inferior Screw Fixation Decreases Acetabular Component Failure Following Revision Total Hip Arthroplasty. J Arthroplasty. 2024. PMID: 38649067. doi:10.1016/j.arth.2024.04.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。