文献速递关节外科

全膝关节置换术中股骨远端解剖参考:假体方位对股骨假体尺寸的影响

Anatomic Referencing of the Distal Femur in Total Knee Arthroplasty: The Impact of Orientation on Femoral Component Size.
PubMed 文献 · J Arthroplasty · 2024-04-09

研究基于446例股骨CT数字表面模型,模拟全膝关节置换术中股骨假体在屈曲0°、3°、6°及外旋0°、3°、5°、7°下的尺寸与放置。结果显示外旋增加前后径高度并增大理想假体尺寸,屈曲在固定外旋下降低前后径高度;解剖参考下可计入方位变化对假体尺寸的影响。

要点

  • 屈曲角度固定时,增加外旋会增大股骨假体前后径高度及理想尺寸。
  • 0°屈曲下外旋从3°降至0°,88%患者假体尺寸减小1号。
  • 3°屈曲伴3°外旋时,86%患者假体尺寸与0°屈曲0°外旋相同。

核心结论

  • 屈曲在固定外旋下降低股骨假体前后径高度。
  • 股骨假体外旋在所有测试屈曲角度下均增加前后径高度,导致维持后髁偏移所需的理想假体尺寸增大。
  • 采用解剖参考时,可计入股骨假体方位改变及随之发生的假体尺寸变化。

研究设计与样本

  • 使用已建立CT数据库中的446例股骨创建数字表面模型。
  • 假设相对后髁中立(0°)屈曲和中立(3°)旋转,进行虚拟骨切除、假体 sizing 和假体放置。
  • 假体尺寸增量为2 mm,将合适尺寸的股骨假体与前方皮质齐平放置以最佳恢复后髁偏移。
  • 使用3°和6°屈曲及0°、5°、7°外旋重复 sizing 和放置。

主要发现

  • 0°屈曲下,外旋从3°降至0°导致前后径高度平均减少1.9 mm,对应88%患者假体尺寸减小1号。
  • 7°外旋下,假体尺寸平均增加2.5 mm,对应80%患者尺寸增加。
  • 3°屈曲伴3°外旋导致前后径高度减少2.2 mm(93%患者尺寸减小1号)。
  • 3°屈曲伴3°外旋时,86%患者假体尺寸与0°屈曲0°外旋相同。
  • 3°屈曲下,外旋从3°增至5°和7°时前后径高度分别平均增加1.2 mm和3.1 mm;屈曲从3°增至6°延长该效应。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Anatomic referencing in total knee arthroplasty places the femoral component flush to the anterior cortex while maintaining posterior condylar offset (PCO). The intent of this study was to evaluate how component position influences the femoral component size. METHODS: Digital surface models were created using 446 femora from an established computed tomography database. Virtual bone resections, component sizing, and component placement were performed assuming neutral (0°) flexion and neutral (3°) rotation relative to the posterior condyles. The appropriately sized femoral component, which had 2 mm of incremental size, was placed flush with the anterior cortex for optimal restoration of the PCO. Sizing and placement were repeated using 3 and 6° flexion and 0, 5, and 7° external rotation (ER). RESULTS: At 0° flexion, decreasing ER from 3 to 0° resulted in an average decreased anterior-posterior height (APH) of 1.9 mm, corresponding to a component size decrease of 1 for 88% of patients. At 7° ER, component size increased by an average of 2.5 mm, corresponding to a size increase for 80% of patients. Flexing the femoral component to 3° with ER at 3° resulted in a decrease in APH of 2.2 mm (1 size decrease in 93% of patients). At 3° flexion and 3° ER, 86% had the same component size as at 0° flexion and 0° ER. Increasing ER at 3° flexion increased APH by 1.2 mm at 5° and 3.1 mm at 7° on average, relative to 3° ER. Increasing flexion from 3 to 6° extended this effect. CONCLUSIONS: Flexion decreases the APH when the ER is held constant. The ER of the femoral component increases the APH across all tested flexion angles, causing an increase in the ideal femoral component size to maintain PCO. With anatomic referencing, alterations in femoral component positioning and subsequent changes in component size can be accounted for.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Campbell BR, Weinberg M, Bischoff JE, et al. Anatomic Referencing of the Distal Femur in Total Knee Arthroplasty: The Impact of Orientation on Femoral Component Size. J Arthroplasty. 2024. PMID: 38599527. doi:10.1016/j.arth.2024.04.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。