文献速递关节外科

全膝关节置换术中的力线:避免从内翻跨越到外翻

Alignment in Total Knee Arthroplasty: Avoid Crossing Over From Varus to Valgus.
PubMed 文献 · J Arthroplasty · 2024-04-26

该回顾性分析纳入409例初次全膝关节置换术患者,按术前力线(内翻>0°、外翻<0°)及术后力线亚组比较患者报告结局与膝关节活动度。结果显示,术前内翻患者术后过度矫正至外翻(VAR-CO组)在术后3、6、12个月KOOS-JR评分较低,且术后6–12周活动度较中立位及残余内翻组降低;术前外翻患者术后残余外翻(VAL-rVAL组)在术后6–12周屈膝活动度较中立位及跨越至内翻组降低。结论提示术后外翻力线(跨越至外翻或残余外翻)可能带来较差结局。

要点

  • 术前内翻患者术后跨越至外翻(VAR-CO组)在术后3、6、12个月KOOS-JR评分低于中立位组(P<.05)。
  • VAR-CO组术后6–12周活动度低于VAR-NEUT组和VAR-rVAR组(P<.05)。
  • 术前外翻患者术后残余外翻(VAL-rVAL组)术后6–12周屈膝活动度低于VAL-NEUT组和VAL-CO组。

核心结论

  • 术后外翻力线无论通过跨越至外翻(VAR-CO)还是残余外翻(VAL-rVAL),可能比矫正至中立位或轻度内翻带来更差的结局。

研究设计与样本

  • 回顾性分析,纳入单中心初次全膝关节置换术患者409例,使用全长下肢X线片测量术前和术后力线。
  • 按术前力线分为内翻(>0°)和外翻(<0°),再根据术后力线分为中立位(0°±2)、残余同向力线(内翻≥3°或外翻≤-3°)和跨越至对侧力线(内翻跨越至外翻≤-3°或外翻跨越至内翻≥3°)亚组。
  • 采用重复时间方差分析及Bonferroni事后检验比较各术后力线亚组的结局。

主要发现

  • 术前内翻患者中,VAR-CO组(过度矫正至外翻-4.03°±1.95°)在术后3、6、12个月KOOS-JR评分低于NEUT组(P<.05)。
  • VAR-CO组术后6–12周活动度低于VAR-NEUT组和VAR-rVAR组(P<.05)。
  • 术前外翻患者中,VAL-rVAL组(残余外翻-4.39°±1.39°)术后6–12周屈膝活动度低于VAL-NEUT组和VAL-CO组。

关键数值与推荐

  • 术前内翻定义为>0°,术前外翻定义为<0°;术后中立位为0°±2,残余内翻为≥3°,跨越至外翻为≤-3°,残余外翻为≤-3°,跨越至内翻为≥3°。
  • KOOS-JR评分在术前及术后6周、3、6、12个月收集;膝关节活动度在术后2周、6–12周及>6个月收集。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ideal target limb alignment remains a debated topic in total knee arthroplasty (TKA). We aimed to determine the effect of limb alignment correction on patient-reported outcomes and knee range of motion (ROM) following TKA. METHODS: In this retrospective analysis, patients (N = 409) undergoing primary TKA at a single institution were studied. Using full leg-length radiographs, limb alignment was measured preoperatively and postoperatively. Patients were categorized by preoperative (Preop) alignment (varus > 0°; valgus < 0°). Preop varus patients were then divided as follows based on postoperative alignment: neutral (VAR-NEUT, 0°± 2), remaining in varus (VAR-rVAR, ≥3°), and cross-over to valgus (VAR-CO, ≤-3°). Similarly, Preop valgus patients were divided as follows for postoperative alignment: neutral (VAL-NEUT, 0°± 2), remaining in valgus (VAL-rVAL, ≤-3°), and cross-over to varus (VAL-CO, ≥3°). The Knee Injury and Osteoarthritis Outcome Score for Joint Replacement survey scores were collected at preoperatively as well as at 6 weeks, 3, 6, and 12 months postoperatively. Knee ROM was collected at 2 weeks, 6 to 12 weeks, and >6 months postoperatively. An analysis of variance repeated on time followed by a Bonferroni post hoc test was used to compare outcomes for the postoperative alignment subgroups. RESULTS: Preop Varus patients: Those in the VAR-CO group (overcorrected to -4.03° ± 1.95valgus) were observed to have lower Knee Injury and Osteoarthritis Outcome Score for Joint Replacement scores at 3, 6, and 12 months postoperatively compared to those in the NEUT group (P < .05). This finding was paired with reduced ROM at 6 to 12 weeks postoperatively in the VAR-CO group compared to VAR-NEUT and VAR-rVAR (P < .05). Preop Valgus patients: Those in the VAL-rVal group (left in -4.39° ± 1.39valgus) were observed to have reduced knee flexion at 6 to 12 weeks postoperatively compared to VAL-NEUT and VAL-CO. CONCLUSIONS: These findings indicate that postoperative valgus alignment via either crossing over to valgus (VAR-CO) or remaining in valgus (VAL-rVAL) alignment may result in less preferable outcomes than correction to neutral or slightly varus alignment.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Gurusamy P, Liu JW, Sullivan TC, et al. Alignment in Total Knee Arthroplasty: Avoid Crossing Over From Varus to Valgus. J Arthroplasty. 2024. PMID: 38679348. doi:10.1016/j.arth.2024.04.057

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。