文献速递骨质疏松与代谢性骨病

基于CT图像的生物标志物用于骨质疏松性骨折机会性筛查:系统综述与Meta分析

CT image-based biomarkers for opportunistic screening of osteoporotic fractures: a systematic review and meta-analysis.
PubMed 文献 · Osteoporos Int · 2024-02-14

该系统综述与Meta分析评估了基于常规临床CT扫描的图像生物标志物对髋部、椎体和主要骨质疏松性骨折的判别能力,共纳入61项研究,其中35项进入Meta分析。与面积骨密度(AUC 0.73)相比,有限元衍生参数(AUC 0.77,p<0.01)和体积骨密度(AUC 0.76,p<0.01)的合并AUC显著更高,而图像衰减(AUC 0.73)无显著差异。作者认为体积骨密度和有限元参数可能显著改善机会性CT评估对骨质疏松性骨折的判别。

要点

  • 有限元参数合并AUC 0.77,显著高于面积骨密度的0.73(p<0.01)。
  • 体积骨密度合并AUC 0.76,显著高于面积骨密度的0.73(p<0.01)。
  • 图像衰减合并AUC 0.73,与面积骨密度无显著差异(p=0.93)。

核心结论

  • 与面积骨密度相比,体积骨密度和有限元衍生参数可能显著改善机会性CT评估对骨质疏松性骨折的判别。

研究设计与样本

  • 系统检索PubMed MEDLINE、Embase、Cochrane和Web of Science从最早索引日期至2023年7月,共纳入61项研究,其中35项进行Meta分析,其余定性综合。
  • 使用改良的QUADAS-2清单评估研究质量,Meta分析采用随机效应模型。

主要发现

  • 有限元衍生参数预测骨质疏松性骨折的合并AUC为0.77(95%CI 0.72-0.81),显著高于面积骨密度的合并AUC 0.73(95%CI 0.71-0.75),p<0.01。
  • 体积骨密度预测骨质疏松性骨折的合并AUC为0.76(95%CI 0.71-0.81),显著高于面积骨密度的合并AUC 0.73(95%CI 0.71-0.75),p<0.01。
  • 图像衰减预测骨质疏松性骨折的合并AUC为0.73(95%CI 0.66-0.79),与面积骨密度的合并AUC 0.73(95%CI 0.71-0.75)无显著差异,p=0.93。

关键数值与推荐

  • 面积骨密度预测骨质疏松性骨折的合并AUC为0.73(95%CI 0.71-0.75)。
  • 有限元衍生参数预测骨质疏松性骨折的合并AUC为0.77(95%CI 0.72-0.81)。
  • 体积骨密度预测骨质疏松性骨折的合并AUC为0.76(95%CI 0.71-0.81)。
  • 图像衰减预测骨质疏松性骨折的合并AUC为0.73(95%CI 0.66-0.79)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The use of opportunistic computed tomography (CT) image-based biomarkers may be a low-cost strategy for screening older individuals at high risk for osteoporotic fractures and populations that are not sufficiently targeted. This review aimed to assess the discriminative ability of image-based biomarkers derived from existing clinical routine CT scans for hip, vertebral, and major osteoporotic fracture prediction. A systematic search in PubMed MEDLINE, Embase, Cochrane, and Web of Science was conducted from the earliest indexing date until July 2023. The evaluation of study quality was carried out using a modified Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2) checklist. The primary outcome of interest was the area under the curve (AUC) and its corresponding 95% confidence intervals (CIs) obtained for four main categories of biomarkers: areal bone mineral density (BMD), image attenuation, volumetric BMD, and finite element (FE)-derived biomarkers. The meta-analyses were performed using random effects models. Sixty-one studies were included in this review, among which 35 were synthesized in a meta-analysis and the remaining articles were qualitatively synthesized. In comparison to the pooled AUC of areal BMD (0.73 [95% CI 0.71-0.75]), the pooled AUC values for predicting osteoporotic fractures for FE-derived parameters (0.77 [95% CI 0.72-0.81]; p < 0.01) and volumetric BMD (0.76 [95% CI 0.71-0.81]; p < 0.01) were significantly higher, but there was no significant difference with the pooled AUC for image attenuation (0.73 [95% CI 0.66-0.79]; p = 0.93). Compared to areal BMD, volumetric BMD and FE-derived parameters may provide a significant improvement in the discrimination of osteoporotic fractures using opportunistic CT assessments.

来源:Osteoporos Int,查看原文。版权归原作者所有。

引用

  1. Praveen AD, Sollmann N, Baum T, et al. CT image-based biomarkers for opportunistic screening of osteoporotic fractures: a systematic review and meta-analysis. Osteoporos Int. 2024. PMID: 38353706. doi:10.1007/s00198-024-07029-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。