文献速递关节外科运动医学

膝内翻性骨关节炎高位胫骨截骨术前的后足对线与术后结局:我们以足跟而非踝行走

Preoperative Hindfoot Alignment and Outcomes After High Tibial Osteotomy for Varus Knee Osteoarthritis: We Walk on Our Heel, Not Our Ankle.
PubMed 文献 · J Bone Joint Surg Am · 2024-02-22

本研究回顾了2018年至2020年间接受高位胫骨截骨术(HTO)的128例患者,根据术前后足对线分为后足外翻组(n=94)和后足内翻组(n=34)。结果显示,后足外翻组的后足对线角(HAA)从术前平均5.1°外翻显著改善至术后平均1.9°外翻(p<0.001),而后足内翻组无显著改善(p=0.236)。后足内翻组术后临床结局(疼痛和AOFAS踝-后足评分)较后足外翻组更差,作者认为对于术前固定性后足内翻畸形的患者,可能需要修改手术方式以使地面机械轴(GA)更向外侧偏移。

要点

  • 后足外翻组HAA从术前平均5.1°外翻改善至术后平均1.9°外翻(p<0.001),后足内翻组无显著改善(p=0.236)。
  • 后足内翻组术后平均HKC角较后足外翻组内翻多2°(1.0° vs 3.0°;p=0.001)。
  • 后足内翻组术后GA通过膝关节的位置较后足外翻组偏内8.0%(55% vs 63%),且临床结局更差。

核心结论

  • 尽管研究结果不足以确定组间临床相关差异,但提示术前固定性后足内翻畸形的患者在接受HTO后矫正不足的发生率更高且临床结局更差,尤其是疼痛。
  • 作者认为,对于这些患者,可能需要修改手术方式以使GA更向外侧偏移。

研究设计与样本

  • 回顾性研究,纳入2018年至2020年间接受HTO的128例患者。
  • 根据术前后足对线将患者分为后足外翻组(n=94)和后足内翻组(n=34)。
  • 术前及术后2年使用全长站立位髋-跟骨X线片测量影像学参数。

主要发现

  • 后足外翻组平均HAA从术前5.1°外翻改善至术后1.9°外翻(p<0.001);后足内翻组HAA无显著改善(p=0.236)。
  • 后足内翻组术后平均HKC角为1.0°,后足外翻组为3.0°,后足内翻组内翻多2°(p=0.001)。
  • 后足内翻组GA通过膝关节的位置为55%,后足外翻组为63%,后足内翻组偏内8.0%。
  • 后足内翻组术后KOOS疼痛评分和AOFAS踝-后足评分均差于后足外翻组。

关键数值与推荐

  • 后足对线通过后足对线角(HAA)评估。
  • 下肢对线参数包括HKA角、HKC角以及MA和GA的WBL比率。
  • WBL比率定义:GA或MA通过胫骨宽度的点与股骨头中心至跟骨最低点(GA)或距骨中心(MA)连线的交点,内侧缘为0%,外侧缘为100%。

临床怎么用

  • 作者认为,对于术前固定性后足内翻畸形的患者,可能需要修改手术方式以使GA更向外侧偏移。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UPDATE: This article was updated on May 15, 2024 because of previous errors, which were discovered after the preliminary version of the article was posted online. On page 898, in the section entitled "Materials and Methods," the sentence that had read "The WBL ratio of the knee joint was defined as the point where the GA or MA passed through the width of the tibia and intersected a line from the center of the femoral head to the center of the calcaneus (for the GA) or talus (for the MA), with the medial edge defined as 0% and the lateral edge as 100%." now reads "The WBL ratio of the knee joint was defined as the point where the GA or MA passed through the width of the tibia and intersected a line from the center of the femoral head to the lowest point of the calcaneus (for the GA) or the center of the talus (for the MA), with the medial edge defined as 0% and the lateral edge as 100%." Likewise, in the legend for Figure 3 on page 899, the sentence that had read "Depiction of the ground mechanical axis (GA), defined as the line (represented by the solid red line) from the center of the femoral head to the ground reaction point at the center of the calcaneus, passing lateral to the traditional mechanical axis (MA; represented by the dashed red line)." now reads "Depiction of the ground mechanical axis (GA), defined as the line (represented by the solid red line) from the center of the femoral head to the ground reaction point at the lowest point of the calcaneus, passing lateral to the traditional mechanical axis (MA; represented by the dashed red line)." Finally, on page 903, "HKA" was changed to "HKA angle" in Table III. BACKGROUND: The hip-to-calcaneus axis, previously known as the ground mechanical axis (GA), ideally passes through the center of the knee joint in the native knee. The aim of this study was to elucidate, with use of hip-to-calcaneus radiographs, changes in knee and hindfoot alignment and changes in outcomes following high tibial osteotomy (HTO). METHODS: We reviewed the records for 128 patients who underwent HTO between 2018 and 2020. Patients were stratified into 2 groups, a hindfoot valgus group (n = 94) and a hindfoot varus group (n = 34), on the basis of their preoperative hindfoot alignment. The hindfoot alignment was evaluated with use of the hindfoot alignment angle (HAA). To evaluate lower-limb alignment, full-length standing posteroanterior hip-to-calcaneus radiographs were utilized to measure 4 radiographic parameters preoperatively and 2 years postoperatively: the hip-knee-ankle (HKA) angle, hip-knee-calcaneus (HKC) angle, and the weight-bearing line (WBL) ratios of the mechanical axis (MA) and GA. RESULTS: The mean HAA improved significantly from 5.1° valgus preoperatively to 1.9° valgus postoperatively in the hindfoot valgus group (p < 0.001). In contrast, in the hindfoot varus group, the HAA showed no meaningful improvement in the coronal alignment of the hindfoot following HTO (p = 0.236). The postoperative mean HKC angle in the hindfoot varus group was 2° more varus than that in the hindfoot valgus group (1.0° versus 3.0°; p = 0.001), and the GA in the hindfoot varus group passed across the knee 8.0% more medially than that in the hindfoot valgus group (55% versus 63% from the most medial to the most lateral part of the tibial plateau). The hindfoot varus group had worse postoperative clinical outcomes than the hindfoot valgus group in terms of the mean Knee injury and Osteoarthritis Outcome Score for pain and American Orthopaedic Foot & Ankle Society Ankle-Hindfoot Score. CONCLUSIONS: Although our findings did not provide sufficient evidence to establish clinically relevant differences between the groups, they indicated that the group with a preoperative fixed hindfoot varus deformity had a higher rate of undercorrection and worse clinical outcomes, especially pain, following HTO. Therefore, modification of the procedure to shift the GA more laterally may be required for these patients. LEVEL OF EVIDENCE: Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Yang HY, Kang JK, Kim JW, et al. Preoperative Hindfoot Alignment and Outcomes After High Tibial Osteotomy for Varus Knee Osteoarthritis: We Walk on Our Heel, Not Our Ankle. J Bone Joint Surg Am. 2024. PMID: 38386715. doi:10.2106/JBJS.23.00720

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。