文献速递关节外科

内侧轴心运动学约束髁型翻修膝关节假体的良好短期生存率:一项IV级回顾性研究

Good Short-Term Survivorship of Constrained Condylar Revision Knee Implants With Medial Pivot Kinematics: A Level IV Retrospective Study.
PubMed 文献 · J Arthroplasty · 2024-02-22

这项IV级回顾性队列研究纳入49例使用新型内侧轴心运动学约束髁型翻修全膝关节系统的患者,最低随访四年,无菌性松动免除生存率为100%,全因翻修生存率为92%,45例完成遗忘关节评分平均49.8分,作者认为短期患者报告结局良好,未来需评估中长期生存率。

要点

  • 49例患者随访四年,无菌性松动免除生存率100%,全因翻修生存率92%。
  • 4例再次翻修原因分别为假体周围感染2例、冠状面不稳1例、创伤性膝关节脱位1例。
  • 45例完成遗忘关节评分,平均49.8分(±32.8,范围6.25至100)。

核心结论

  • 在四年中期随访时,这种设计为内侧轴心运动学的新型约束髁型翻修全膝关节系统患者报告结局良好,无因无菌性松动而翻修。
  • 作者认为未来研究应评估这种创新假体的中期和长期生存率。

研究设计与样本

  • 回顾性队列研究,收集所有使用新型内侧轴心约束髁型系统行翻修全膝关节置换术且最低临床随访四年的患者临床数据。
  • 基于病历回顾分析患者人口学资料、生存率、并发症和遗忘关节评分。

主要发现

  • 49例患者可随访,无菌性松动免除生存率为100%。
  • 全因翻修生存率为92%。
  • 4例患者随后接受再次翻修,原因包括假体周围感染2例、冠状面不稳1例和创伤性膝关节脱位1例。
  • 45例患者完成遗忘关节评分,平均49.8分(±32.8,范围6.25至100)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The need for revision total knee arthroplasty surgery is increasing worldwide, and, in many cases, a constrained implant is required to provide joint stability. The purpose of this study was to examine the early loosening and functional outcome of a novel constrained condylar (CCK) revision total knee system designed to have medial pivot (MP) kinematics. METHODS: A retrospective cohort study was performed, collecting clinical data from all patients who underwent revision total knee arthroplasty using a novel MP CCK system with a minimum four-year clinical follow-up. Patient demographics, survivorship, complications, and Forgotten Joint Score were analyzed based upon chart review. RESULTS: There were 49 patients available for follow-up, who had a 100% survivorship free of aseptic loosening. All-cause revision survivorship was 92%. There were 4 patients who subsequently underwent rerevision. The causes for rerevision included periprosthetic joint infection in 2 patients, coronal plane instability in one patient, and a traumatic knee dislocation in one patient. There were 45 patients who completed the Forgotten Joint Score, who had an average of 49.8 (± 32.8, range 6.25 to 100). CONCLUSIONS: At 4 years, mid-term follow-up, this novel CCK revision total knee system designed to have MP kinematics had good patient-reported outcomes with no revision for aseptic loosening. Future studies should evaluate the mid- and long-term survivorship of this innovative implant.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Greenberg A, Cohen D, Shahabinezhad A, et al. Good Short-Term Survivorship of Constrained Condylar Revision Knee Implants With Medial Pivot Kinematics: A Level IV Retrospective Study. J Arthroplasty. 2024. PMID: 38395111. doi:10.1016/j.arth.2024.02.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。