主观髋关节价值评分是评估初次全髋关节置换术后髋关节功能的有效、可靠且反应灵敏的工具
研究前瞻性纳入137例初次全髋关节置换患者,术前及术后6周、3个月、6个月、1年收集主观髋关节价值评分(SHV)与改良Harris髋关节评分(mHHS),评估SHV的心理测量学特性并定义最小临床重要差异(MCID)。结果显示SHV与mHHS显著相关,重测信度和反应性显著,MCID为10.06%,地板和天花板效应与mHHS相当。结论认为SHV是有效、可靠、反应灵敏的单条目评分,易于收集和解读,支持其用于临床实践。
要点
- SHV与mHHS在术前及术后各随访点均显著相关(P=0.001)。
- SHV的重测信度(rs=0.74;P=0.001)和反应性(rs=0.24;P=0.007)均显著。
- SHV的MCID为10.06%,地板和天花板效应与mHHS相当。
核心结论
- SHV是评估关节置换患者髋关节功能的有效、可靠且反应灵敏的单条目评分,能检测关节功能的临床相关变化,且易于收集和解读,支持其在临床实践中实施。
研究设计与样本
- 前瞻性纳入2020年6月至2021年8月期间接受初次全髋关节置换的连续患者137例,术前及术后6周、3个月、6个月、1年收集SHV和mHHS,评估效度、信度、反应性、MCID及地板/天花板效应。
主要发现
- SHV与mHHS显著相关:术前rs=0.532,6周rs=0.649,3个月rs=0.765,6个月rs=0.854,1年后rs=0.879(P=0.001)。
- 重测信度rs=0.74(P=0.001),反应性rs=0.24(P=0.007),均显示显著相关。
- SHV的MCID为10.06%,地板和天花板效应与mHHS相当。
关键数值与推荐
- SHV的MCID为10.06%。
- SHV与mHHS在术前(rs=0.532)、6周(rs=0.649)、3个月(rs=0.765)、6个月(rs=0.854)和1年(rs=0.879)均显著相关(P=0.001)。
- 重测信度rs=0.74(P=0.001),反应性rs=0.24(P=0.007)。
临床怎么用
- 作者认为SHV易于收集和解读,支持其在临床实践中实施。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patient-reported outcome measures are essential tools in clinical decision-making and research. Multi-item scores like the modified Harris Hip Score (mHHS) are time-consuming to collect and evaluate. The subjective hip value (SHV), as a single-item value, assesses hip function with one question: "What is the overall percent value of your hip if a completely normal hip represents 100%?". The aims of our study were to assess the psychometric properties, and thus validity, reliability, and responsiveness; and to define the minimal clinically important difference (MCID) of the SHV in patients undergoing total hip arthroplasty. METHODS: A total of 137 consecutive patients who underwent primary total hip arthroplasty between June 2020 and August 2021 were prospectively enrolled. A SHV and mHHS were collected preoperatively and at follow-ups (6 weeks, 3 months, 6 months, and 1 year). Validity, reliability, responsiveness, MCID, and floor/ceiling effects were evaluated. RESULTS: There was a significant correlation between SHV and mHHS (P = .001) preoperatively (rs = 0.532), 6 weeks (rs = 0.649), 3 months (rs = 0.765), 6 months (rs = 0.854), and after 1 year (rs = 0.879). Test-retest reliability (rs = 0.74; P = .001) and responsiveness (rs = 0.24; P = .007) showed significant correlations. The MCID for SHV was 10.06%. Floor- and ceiling-effects were comparable to the mHHS. CONCLUSIONS: The SHV is a valid, reliable, and responsive single-item score for the assessment of hip joint function in arthroplasty patients. It can detect clinically relevant changes in joint function and is easy to collect and interpret, which justifies its implementation in clinical practice.
引用
- Leopold VJ, Homm PM, Krüger D, et al. The Subjective Hip Value is a Valid, Reliable, and Responsive Instrument for Assessing Hip Function in Primary Total Hip Arthroplasty. J Arthroplasty. 2024. PMID: 38336302. doi:10.1016/j.arth.2024.01.061
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。