羟基磷灰石涂层三锥度股骨柄内侧领与股骨颈接触对假体周围骨密度无影响

No Impact of Contact Between the Medial Collar of a Hydroxyapatite-Coated Triple-Tapered Stem and the Femoral Neck on Periprosthetic Bone Mineral Density.
PubMed 文献 · J Arthroplasty · 2024-02-14

回顾性单中心研究纳入62例使用羟基磷灰石涂层三锥度短柄行单侧全髋关节置换的患者,术后3个月CT评估内侧领与股骨颈接触情况并分组。接触组51例、非接触组11例,两组在临床评分改善、假体固定、皮质肥厚、三维力线及假体周围骨密度变化上均无差异。结论认为内侧领与股骨颈接触与否不影响术后骨密度变化及影像学或临床结果。

要点

  • 接触组51例与非接触组11例在WOMAC和JOA评分改善上无差异。
  • 两组假体固定、皮质肥厚发生及三维股骨柄力线均无差异。
  • 两组骨密度均在7区下降最明显,组间无差异。

核心结论

  • 内侧领与股骨颈接触与否不影响术后骨密度变化及影像学或临床结果。

研究设计与样本

  • 回顾性单中心研究纳入62例计划行单侧全髋关节置换并使用羟基磷灰石涂层三锥度短柄的患者,术后随访至少1年。
  • 所有患者股骨髓腔形态均为Dorr B型。
  • 术后第3个月通过计算机断层扫描评估内侧领与股骨颈接触情况并分为两组。

主要发现

  • 接触组51例,非接触组11例。
  • 两组在WOMAC和日本骨科协会评分改善、假体固定、皮质肥厚发生及三维股骨柄力线方面均无差异。
  • 仅接触组6例(12%)在3、4、5区出现放射透亮线,两组间无统计学差异。
  • 两组骨密度均在7区下降最明显,组间无差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Hydroxyapatite-coated, triple-tapered, shorter-length stems with a medial collar have been reported with good results for a few years. We investigated whether contact between the medial collar and femoral neck affects clinical outcomes and changes in bone mineral density (BMD) in patients who have this type of stem in their total hip arthroplasty construct. METHODS: This was a retrospective, single-center study involving 62 patients scheduled for unilateral total hip arthroplasty using a hydroxyapatite-coated, triple-tapered, shorter-length stem who were followed for at least 1 year postoperatively. All patients had a Dorr type B femoral canal shape. Contact between the medial collar and the femoral neck was evaluated by computed tomography at the third postoperative month, and patients were classified into 2 groups. Postoperative clinical outcomes were investigated by the Western Ontario and McMaster Universities Arthritis Index and the Japanese Orthopaedic Association scores; radiological evaluation included stem fixation, spot welds and cortical hypertrophy, postoperative 3-dimensional stem alignment, and periprosthetic BMD changes. RESULTS: There were 51 patients in the Contact + group (collar and neck contact) and 11 in the Contact-group (no contact). There were no differences between the 2 groups in the improvement of Western Ontario and McMaster Universities Arthritis Index and Japanese Orthopaedic Association scores, stem fixation, occurrence of cortical hypertrophy, or 3-dimensional stem alignment. Radiolucent lines were present in zones 3, 4, and 5 in 6 patients (12%) in the Contact + group only, who had no statistical difference between the 2 groups. Bone mineral density (BMD) decreased most in zone 7 in both groups, with no difference between the 2 groups. CONCLUSIONS: The presence or absence of contact between the medial collar and femoral neck did not affect postoperative BMD changes or radiological or clinical results. LEVEL OF EVIDENCE: Therapeutic Level III.

来源:J Arthroplasty,查看原文。版权归原作者所有。