文献速递关节外科

超 congruent 聚乙烯衬垫不影响外翻畸形全膝关节置换术的生存率

Ultracongruent Polyethylene Liners Do Not Affect Survival of Total Knee Arthroplasty for Valgus Deformity.
PubMed 文献 · J Arthroplasty · 2024-02-12

该研究回顾了2013至2019年由关节置换专科医生完成的549例外翻膝初次全膝关节置换术,比较后稳定型与超 congruent 聚乙烯衬垫的生存率。中位随访4.9年,两组全因翻修率无差异(超 congruent 组2.7% vs 后稳定型组3.4%,P=0.90),超 congruent 衬垫与翻修无关联(HR 0.76,95%CI 0.26-2.21,P=0.62),八年生存率无差异。作者认为现代聚乙烯设计下超 congruent 衬垫可用于外翻畸形而不增加失败风险。

要点

  • 外翻膝全膝关节置换术中,超 congruent 衬垫与后稳定型衬垫的全因翻修率无显著差异(2.7% vs 3.4%,P=0.90)。
  • 多变量回归显示超 congruent 衬垫与翻修无关联(HR 0.76,95%CI 0.26-2.21,P=0.62)。
  • 两组八年全因翻修生存率无差异,包括无菌性和感染性失败。

核心结论

  • 在外翻畸形全膝关节置换术中,使用超 congruent 聚乙烯衬垫未降低生存率,全因翻修率与后稳定型衬垫无显著差异。
  • 作者认为,在现代聚乙烯设计下,超 congruent 衬垫可用于外翻畸形而不增加失败风险。

研究设计与样本

  • 回顾性 review 了2013至2019年由关节置换专科医生完成的549例外翻膝初次全膝关节置换术。
  • 记录人口学资料、合并症、术前畸形程度、所用植入物及至末次随访的全因翻修。
  • 采用 Cox 回归分析评估各队列至全因翻修的生存率,平均随访4.9年(范围2至9年)。

主要发现

  • 超 congruent 衬垫403例,后稳定型衬垫146例;两组患者年龄(68岁 vs 67岁,P=0.30)、体重指数(30.9 vs 30.4,P=0.36)及畸形程度(8.6度 vs 8.8度,P=0.75)无差异。
  • 末次随访时,后稳定型组翻修5例(3.4%),超 congruent 组翻修11例(2.7%),P=0.90。
  • 两组最常见翻修原因均为假体周围关节感染(后稳定型组4例;超 congruent 组8例)。
  • 控制年龄、体重指数、Elixhauser 合并症评分、性别及畸形程度的多变量回归分析显示,超 congruent 聚乙烯衬垫与翻修无关联(HR 0.76;95%CI 0.26至2.21;P=0.62)。
  • 两组八年全因翻修生存率无差异,包括无菌性和感染性失败。

关键数值与推荐

  • 超 congruent 组翻修率2.7%(11例)vs 后稳定型组3.4%(5例),P=0.90。
  • 超 congruent 衬垫与翻修关联的 HR 0.76(95%CI 0.26至2.21,P=0.62)。
  • 两组八年全因翻修生存率无差异。

临床怎么用

  • 作者认为,现代聚乙烯设计下超 congruent 衬垫可用于外翻畸形全膝关节置换术而不增加失败风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Valgus knee deformity is observed in nearly 10% of patients undergoing total knee arthroplasty (TKA). The degree of polyethylene constraint required to balance a valgus knee remains controversial, and historically, posterior-stabilized (PS) designs have been favored. This study evaluated the survivorship of TKA done in valgus knees based on implant design and specifically compared posterior-stabilized (PS) and ultracongruent (UC) liners. METHODS: A total of 549 primary TKAs performed on valgus knees by fellowship-trained arthroplasty surgeons from 2013 to 2019 were reviewed. Demographics, comorbidities, degrees of preoperative deformity, implants used, and all-cause revisions until final follow-up were recorded. Cox regression analyses evaluated survival to all-cause revision in each cohort. The mean follow-up was 4.9 years (range, 2 to 9). RESULTS: There were 403 UC liners compared to 146 PS liners. There was no difference in patient age (68 versus 67 years; P = .30), body mass index (30.9 versus 30.4; P = .36), or degree of deformity (8.6 versus 8.8 degrees; P = .75) between the cohorts. At final follow-up, there were 5 revisions in the PS cohort (3.4%) versus 11 revisions in the UC cohort (2.7%) (P = .90). The most common reason for revision in both cohorts was periprosthetic joint infection (4 PS; 8 UC). Multivariable regression analyses controlling for age, body mass index, Elixhauser comorbidity score, sex, and degree of deformity demonstrated UC polyethylene liners were not associated with revision (hazard ratio 0.76; 95% confidence interval [CI] 0.26 to 2.21; P = .62). There was no difference in eight-year survivorship to all-cause revision, including aseptic and septic failure. CONCLUSIONS: Alternative polyethylene liners from the historically utilized PS liners for TKA for valgus deformity did not reduce survivorship. With modern polyethylene designs, UC inserts can be utilized for this deformity without increasing the risk of failure.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Cochrane NH, Kim BI, Holland CT, et al. Ultracongruent Polyethylene Liners Do Not Affect Survival of Total Knee Arthroplasty for Valgus Deformity. J Arthroplasty. 2024. PMID: 38355064. doi:10.1016/j.arth.2024.02.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。