文献速递关节外科创伤骨科

全膝关节置换术后股四头肌腱伸膝装置断裂的相关危险因素

Risk Factors Associated With Quadriceps Tendon Extensor Mechanism Disruption Following Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2024-02-06

本研究基于PearlDiver行政索赔数据库进行回顾性队列分析,纳入126,819例接受全膝关节置换术且随访至少5年的患者,股四头肌腱伸膝装置断裂发生率为0.41%(517例)。多因素分析显示,Charlson合并症指数升高(OR 1.10)、肥胖(OR 1.49)及术后任何时间使用氟喹诺酮类(OR 1.24)与股四头肌腱伸膝装置断裂显著相关。

要点

  • 全膝关节置换术后股四头肌腱伸膝装置断裂发生率为0.41%(517/126,819)。
  • Charlson合并症指数升高与股四头肌腱伸膝装置断裂风险增加相关(OR 1.10)。
  • 肥胖(OR 1.49)及术后使用氟喹诺酮类(OR 1.24)亦为显著相关危险因素。

核心结论

  • 全膝关节置换术后股四头肌腱伸膝装置断裂的发生率为0.41%。
  • 全膝关节置换术后股四头肌腱伸膝装置断裂的危险因素包括Charlson合并症指数升高、肥胖及术后使用氟喹诺酮类。

研究设计与样本

  • 回顾性队列分析,使用PearlDiver行政索赔数据库。
  • 纳入无股四头肌腱伸膝装置断裂病史、接受全膝关节置换术且术后随访至少5年的患者,共126,819例。
  • 股四头肌腱伸膝装置断裂包括股四头肌腱断裂、髌腱断裂或髌骨骨折。

主要发现

  • 共发生517例股四头肌腱伸膝装置断裂,发生率为0.41%。
  • 多因素分析显示,Charlson合并症指数升高与股四头肌腱伸膝装置断裂显著相关(OR 1.10,95%CI 1.07-1.13,P<.001)。
  • 肥胖与股四头肌腱伸膝装置断裂显著相关(OR 1.49,95%CI 1.24-1.79,P<.001)。
  • 全膝关节置换术后任何时间使用氟喹诺酮类与股四头肌腱伸膝装置断裂显著相关(OR 1.24,95%CI 1.01-1.52,P=.036)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Quadriceps tendon extensor mechanism disruption is an infrequent but devastating complication after total knee arthroplasty (TKA). Our knowledge of specific risk factors for this complication is limited by the current literature. Thus, this study aimed to identify potential risk factors for quadriceps tendon extensor mechanism disruption following TKA. METHODS: A retrospective cohort analysis was performed using the PearlDiver Administrative Claims Database. Patients undergoing TKA without a prior history of quadriceps tendon extensor mechanism disruption were identified. Quadriceps tendon extensor mechanism disruption included rupture of the quadriceps tendon, patellar tendon, or fracture of the patella. Patients who had a minimum of 5 years of follow-up after TKA were included. A total of 126,819 patients were included. Among them, 517 cases of quadriceps tendon extensor mechanism disruption occurred (incidence 0.41%). Hypothesized risk factors were compared between those who had postoperative quadriceps tendon extensor mechanism disruption and those who did not. RESULTS: On multivariate analysis, increased Charlson Comorbidity Index (odds ratio (OR): 1.10, 95% confidence interval (CI) [1.07 to 1.13]; P < .001), obesity (OR: 1.49, 95% CI [1.24 to 1.79]; P < .001), and fluoroquinolone use any time after TKA (OR: 1.24, 95% CI [1.01 to 1.52]; P = .036) were significantly associated with quadriceps tendon extensor mechanism disruption. CONCLUSIONS: Our study identified the incidence of quadriceps tendon extensor mechanism disruption following TKA as 0.41%. Identified risk factors for quadriceps tendon extensor mechanism disruption after TKA include an increased Charlson Comorbidity Index, obesity, and use of fluoroquinolones postoperatively.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Lin S, Sproul D, Agarwal A, et al. Risk Factors Associated With Quadriceps Tendon Extensor Mechanism Disruption Following Total Knee Arthroplasty. J Arthroplasty. 2024. PMID: 38331356. doi:10.1016/j.arth.2024.01.053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。