文献速递关节外科

使用无影像第二代机器人系统行翻修全膝关节置换术

Revision Total Knee Arthroplasty With an Imageless, Second-Generation Robotic System.
PubMed 文献 · J Arthroplasty · 2024-02-13

本文回顾性分析了3家三级学术中心2021年3月至2023年5月共115例无影像机器人翻修全膝关节置换术,平均随访13个月,最常见指征为无菌性松动(37%)和不稳定(32%),90天内8次急诊就诊、2次再入院,末次随访5次再手术和2次手法松解,作者认为无影像机器人手术在翻修全膝关节置换术中是有前景的方式,但需进一步开展对比机器人翻修全膝关节置换术与常规翻修全膝关节置换术纵向结局的研究。

要点

  • 最常见翻修指征为无菌性松动(n=42,37%)和不稳定(n=37,32%)。
  • 93%患者关节线恢复至距对侧原生膝5毫米以内,聚乙烯垫中位尺寸为11(四分位距10至13)。
  • 90天内8次急诊就诊、2次再入院;末次随访5次再手术、2次手法松解。

核心结论

  • 本回顾性综述显示良好的术中及90天结局,提示无影像机器人手术在翻修全膝关节置换术中是有前景的方式。
  • 作者认为需进一步开展对比机器人翻修全膝关节置换术与常规翻修全膝关节置换术纵向结局的研究。

研究设计与样本

  • 回顾性综述,纳入2021年3月至2023年5月3家三级学术中心的115例机器人翻修全膝关节置换术。
  • 收集患者人口学资料、围手术期手术数据和90天结局,记录术前和术后疼痛及患者报告结局测量信息系统评分。
  • 患者平均年龄65岁(范围43至88岁),58%为女性,平均随访时间13个月(范围3至51个月)。

主要发现

  • 翻修全膝关节置换术最常见指征为无菌性松动(n=42,37%)和不稳定(n=37,32%)。
  • 83例翻修全膝关节置换术使用后稳定型衬垫,22例使用内翻-外翻限制型衬垫,5例使用铰链型结构。
  • 聚乙烯垫中位尺寸为11(四分位距10至13),93%患者关节线恢复至距对侧原生膝5毫米以内。
  • 术后90天窗口内,有8次急诊就诊和2次再入院。
  • 末次随访时,有5次再手术和2次手法松解;4例患者因浅表伤口裂开需冲洗和清创,1例跌倒后发生关节切开破裂。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Robotic-assisted total knee arthroplasty is increasingly used in revision total knee arthroplasty (rTKA), with imageless systems recently receiving Food and Drug Administration (FDA) approval. However, there remains a paucity of literature on the use of robotic assistance in revision total knee arthroplasty (TKA). This paper describes the imageless surgical technique for robotic revision TKA using a second-generation robotic system and details both intraoperative and 90-day outcomes. METHODS: This was a retrospective review of 115 robotic revision TKAs from March 2021 to May 2023 at 3 tertiary academic centers. Patient demographics, perioperative surgical data, and 90-day outcomes were collected. Pain and Patient-Reported Outcomes Measurement Information System scores preoperatively and postoperatively were recorded. All-cause reoperations at the final follow-up were detailed. The mean patient age was 65 years (range, 43 to 88), and 58% were women. The mean follow-up time was 13 months (range, 3 to 51). RESULTS: The most common indications for rTKA were instability (n = 37, 32%) and aseptic loosening (n = 42, 37%). There were 83 rTKAs to a posterior-stabilized liner, 22 to a varus-valgus constrained liner, and 5 to a hinged construct. The median polyethylene size was 11 (interquartile range, 10 to 13), and 93% of patients had their joint line restored within 5 millimeters of the native contralateral knee. Within the 90-day postoperative window, there were 8 emergency department visits and 2 readmissions. At the final follow-up, there were 5 reoperations and 2 manipulations under anesthesia. There were 4 patients who required irrigation and debridement after superficial wound dehiscence, and one had an arthrotomy disruption after a fall. CONCLUSIONS: This review demonstrates favorable intraoperative and 90-day outcomes and suggests that imageless robotic surgery is a promising modality in rTKA. Further studies comparing the longitudinal outcomes after robotic and conventional rTKA are warranted.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Cochrane NH, Kim BI, Stauffer TP, et al. Revision Total Knee Arthroplasty With an Imageless, Second-Generation Robotic System. J Arthroplasty. 2024. PMID: 38355066. doi:10.1016/j.arth.2024.02.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。