本研究基于国家关节登记与医院统计数据库,对14,122例内侧活动平台单髁膝关节置换术(7,061例骨水泥型与7,061例非骨水泥型)进行倾向性评分匹配,比较假体周围骨折率。P=0.79),无显著差异。作者推测外科医生对非骨水泥组件早期骨折的理论风险有所认识并在胫骨准备中加以注意。

要点

  • 匹配后骨水泥型与非骨水泥型活动平台单髁膝关节置换术的假体周围骨折率无显著差异。
  • 术后前3个月骨折率最高,此后下降并在术后1至10年间保持恒定。
  • 10年累积假体周围骨折率约为1%。

核心结论

  • 活动平台单髁膝关节置换术后的假体周围骨折率较低,10年时约为1%。
  • 匹配后骨水泥型与非骨水泥型假体的骨折率无显著差异。
  • 作者推测外科医生知晓非骨水泥组件早期骨折的理论风险较高,并在胫骨准备中加以注意。

研究设计与样本

  • 基于国家关节登记与医院统计数据库的倾向性评分匹配分析,共纳入14,122例内侧活动平台单髁膝关节置换术,骨水泥型7,061例与非骨水泥型7,061例匹配。
  • 计算累积骨折率并采用Cox回归比较固定方式组间差异,证据等级为III级。

主要发现

  • 3个月假体周围骨折率两组相似(P=0.80),骨水泥型组为0.10%,非骨水泥型组为0.11%。
  • 骨折率在术后前3个月最高,随后下降并在术后1至10年间保持恒定。
  • 1年累积骨折率骨水泥型组为0.2%(CI 0.1-0.3),非骨水泥型组为0.2%(CI 0.1-0.3)。
  • 10年累积骨折率骨水泥型组为0.8%(CI 0.2-1.3),非骨水泥型组为0.8%(CI 0.3-1.3)。
  • 全研究期风险比(HR)为1.06(CI 0.64-1.77;P=0.79)。

关键数值与推荐

  • 骨水泥型组3个月假体周围骨折率为0.10%,非骨水泥型组为0.11%(P=0.80)。
  • 骨水泥型组1年累积骨折率为0.2%(CI 0.1-0.3),非骨水泥型组为0.2%(CI 0.1-0.3)。
  • 骨水泥型组10年累积骨折率为0.8%(CI 0.2-1.3),非骨水泥型组为0.8%(CI 0.3-1.3)。
  • 全研究期风险比(HR)为1.06(CI 0.64-1.77;P=0.79)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Periprosthetic fractures are rare but serious complications of unicompartmental knee arthroplasty (UKA). Although cementless UKA has a lower risk of loosening than cemented, there are concerns that tibial fracture risk may be higher given the reliance on interference fit for primary stability. The risk of fracture and the effect of surgical fixation are currently unknown. We compared the periprosthetic fracture rate following cemented and cementless UKA surgery. METHODS: A total of 14,122 medial mobile-bearing UKAs (7,061 cemented and 7,061 cementless) from the National Joint Registry and Hospital Episodes Statistics database were propensity score-matched. Cumulative fracture rates were calculated and Cox regressions were used to compare fixation groups. RESULTS: The three-month periprosthetic fracture rates were similar (P = .80), being 0.10% in the cemented group and 0.11% in the cementless group. The fracture rates were highest during the first three months postoperatively, but then decreased and remained constant between one and 10 years after surgery. The one-year cumulative fracture rates were 0.2% (confidence interval [CI]: 0.1 to 0.3) for cemented and 0.2% (CI: 0.1 to 0.3) for cementless cases. The 10-year cumulative fracture rates were 0.8% (CI: 0.2 to 1.3) and 0.8% (CI: 0.3 to 1.3), respectively. The hazard ratio during the whole study period was 1.06 (CI: 0.64 to 1.77; P = .79). CONCLUSIONS: The periprosthetic fracture rate following mobile bearing UKA surgery is low, being about 1% at 10 years. There were no significant differences in fracture rates between cemented and cementless implants after matching. We surmise that surgeons are aware of the higher theoretical risk of early fracture with cementless components and take care with tibial preparation. LEVELS OF EVIDENCE: III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Mohammad HR, Judge A, Murray DW, et al. A Comparison of the Periprosthetic Fracture Rate of Cemented and Cementless Mobile Bearing Unicompartmental Knee Arthroplasties: An Analysis of Data From the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. J Arthroplasty. 2024. PMID: 38355062. doi:10.1016/j.arth.2024.02.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。