这项横断面研究纳入股四头肌腱(QT)移植物患者104例,并按年龄、性别和伴随半月板手术匹配腘绳肌腱(HT)和骨-髌腱-骨(BPTB)移植物患者各104例,在术后平均7±1个月以90度/秒角速度测试等速股四头肌肌力。结果显示QT组所有指标的肢体对称指数(LSI)均显著低于HT组和BPTB组,三组平均LSI均未超过90%。

要点

  • QT组等速股四头肌LSI范围为67.5%至75.1%,低于BPTB组的74.4%至81.5%和HT组的84.0%至89.0%。
  • QT组所有变量的LSI均显著低于HT组和BPTB组。
  • 三组移植物的峰力矩平均LSI均未达到90%以上。

核心结论

  • 前交叉韧带重建术后7个月,QT移植物患者的等速股四头肌肌力显著差于HT和BPTB移植物患者。
  • 3种移植物组的股四头肌峰力矩平均LSI均未超过90%。

研究设计与样本

  • 横断面研究,证据等级3。
  • 纳入QT移植物患者104例,并按年龄、性别和伴随半月板手术匹配HT移植物患者104例和BPTB移植物患者104例。
  • 术后平均7±1个月进行临床肌力测试,等速肌力在90度/秒下测量。

主要发现

  • QT组等速股四头肌LSI范围为67.5%至75.1%,BPTB组为74.4%至81.5%,HT组为84.0%至89.0%。
  • QT组较HT组LSI平均差异:峰力矩-17.4%(95%CI -21.7至-13.2,P<.001);总功-15.9%(95%CI -20.6至-11.1,P<.001);屈膝30度力矩-8.8%(95%CI -14.7至-2.9,P=.001);达峰力矩时间-17.7%(95%CI -25.8至-9.6,P<.001)。
  • QT组较BPTB组LSI平均差异:峰力矩-6.9%(95%CI -11.2至-2.7,P<.001);总功-7.7%(95%CI -12.4至-2.9,P<.001);屈膝30度力矩-6.3%(95%CI -12.2至-0.5,P=.03);达峰力矩时间-8.8%(95%CI -16.9至-0.7,P=.03)。
  • 峰力矩平均LSI:QT组67.5%(95%CI 64.8至70.1),HT组84.9%(95%CI 82.4至87.4),BPTB组74.4%(95%CI 72.0至76.9),均未超过90%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Impaired quadriceps muscle strength after anterior cruciate ligament reconstruction (ACLR) is associated with worse clinical outcomes and a risk of reinjuries. Yet, we know little about quadriceps muscle strength in patients reconstructed with a quadriceps tendon (QT) graft, which is increasing in popularity worldwide. PURPOSE: To describe and compare isokinetic quadriceps strength in patients undergoing ACLR with a QT, hamstring tendon (HT), or bone-patellar tendon-bone (BPTB) autograft. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: We included patients with QT grafts (n = 104) and matched them to patients with HT (n = 104) and BPTB (n = 104) grafts based on age, sex, and associated meniscal surgery. Data were collected through clinical strength testing at a mean of 7 ± 1 months postoperatively. Isokinetic strength was measured at 90 deg/s, and quadriceps strength was expressed as the limb symmetry index (LSI) for peak torque, total work, torque at 30° of knee flexion, and time to peak torque. RESULTS: Patients with QT grafts had the most impaired isokinetic quadriceps strength, with the LSI ranging between 67.5% and 75.1%, followed by those with BPTB grafts (74.4%-81.5%) and HT grafts (84.0%-89.0%). Patients with QT grafts had a significantly lower LSI for all variables compared with patients with HT grafts (mean difference: peak torque: -17.4% [95% CI, -21.7 to -13.2], P < .001; total work: -15.9% [95% CI, -20.6 to -11.1], P < .001; torque at 30° of knee flexion: -8.8% [95% CI, -14.7 to -2.9], P = .001; time to peak torque: -17.7% [95% CI, -25.8 to -9.6], P < .001). Compared with patients with BPTB grafts, patients with QT grafts had a significantly lower LSI for all variables (mean difference: peak torque: -6.9% [95% CI, -11.2 to -2.7], P < .001; total work: -7.7% [95% CI, -12.4 to -2.9], P < .001; torque at 30° of knee flexion: -6.3% [95% CI, -12.2 to -0.5], P = .03; time to peak torque: -8.8% [95% CI, -16.9 to -0.7], P = .03). None of the graft groups reached a mean LSI of >90% for peak torque (QT: 67.5% [95% CI, 64.8-70.1]; HT: 84.9% [95% CI, 82.4-87.4]; BPTB: 74.4% [95% CI, 72.0-76.9]). CONCLUSION: At 7 months after ACLR, patients with QT grafts had significantly worse isokinetic quadriceps strength than patients with HT and BPTB grafts. None of the 3 graft groups reached a mean LSI of >90% in quadriceps strength.