文献速递关节外科

髋骨关节炎患者Trendelenburg步态的惯性传感器步态分析

Inertial Sensor Gait Analysis of Trendelenburg Gait in Patients Who Have Hip Osteoarthritis.
PubMed 文献 · J Arthroplasty · 2024-01-26

研究对42例髋骨关节炎患者按临床Trendelenburg步态严重程度(轻度、中度、重度)分组,由单一关节置换外科医生视觉评估,使用无线惯性传感器采集步态参数。结果显示随着Trendelenburg步态加重,Kellgren-Lawrence分级更高、被动髋外展减少,重度组以对侧骨盆偏移为主,对侧单支撑时间偏倚最大。作者认为惯性传感器可行且可揭示传统方法难以辨别的细微模式。

要点

  • Trendelenburg步态加重与更高Kellgren-Lawrence分级和被动髋外展减少相关。
  • 重度组90.0%表现为对侧骨盆偏移,而轻中度组更常见同侧偏移。
  • 对侧单支撑时间偏倚在重度组最大(35.7% vs 50.0% vs 90.0%)。

核心结论

  • 传统认为Trendelenburg步态为躯干向同侧偏移,传感器测量显示随Trendelenburg步态加重负重轴向对侧偏移,此前未见描述。
  • 惯性传感器是可行的定量步态测量工具,可能揭示传统方法不易辨别的细微模式。

研究设计与样本

  • 42例髋骨关节炎患者由单一具有超过30年经验的关节置换外科医生视觉评估分为轻度、中度、重度Trendelenburg步态组。
  • 无线惯性传感器置于髂嵴连线中点采集骨盆偏移、支撑时间、离地对称性、冲击和步频等步态参数,并收集髋部力量、活动度和Kellgren-Lawrence分级临床数据。

主要发现

  • Trendelenburg步态加重与更高平均Kellgren-Lawrence分级相关(2.5 vs 3.2 vs 3.4;P = .014)。
  • Trendelenburg步态加重与被动髋外展减少相关(P = .004)。
  • 重度组以对侧骨盆偏移为主(10例中9例,90.0%),中度组同侧偏移更常见(18例中10例,55.6%),轻度组同侧偏移更常见(14例中9例,64.3%;P = .021)。
  • 对侧单支撑时间偏倚在重度组最大(35.7% vs 50.0% vs 90.0%;P = .027)。
  • 所有组均观察到不对称的离地、冲击和支撑时间。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Gait abnormalities such as Trendelenburg gait (TG) in patients who have hip osteoarthritis (OA) have traditionally been evaluated using clinicians' visual assessment. Recent advances in portable inertial gait sensors offer more sensitive, quantitative methods for gait assessment in clinical settings. This study sought to compare sensor-derived metrics in a cohort of hip OA patients when stratified by clinical TG severity. METHODS: There were 42 patients who had hip OA and were grouped by TG severity (mild, moderate, and severe) through visual assessment by a single arthroplasty surgeon who had > 30 years of experience. After informed consent, wireless inertial sensors placed at the midpoint of the intercristal line collected gait parameters including pelvic shift, support time, toe-off symmetry, impact, and cadence. Clinical data on hip strength, range of motion, and Kellgren-Lawrence grade were collected. RESULTS: Worsening TG severity had a higher mean Kellgren-Lawrence grade (2.5 versus 3.2 versus 3.4; P = .014) and reduced passive hip abduction (P = .004). Severe TG group demonstrated predominantly contralateral pelvic shift (n = 9 of 10, 90.0%), while ipsilateral shift was more frequently detected in moderate (n = 10 of 18, 55.6%) and mild groups (n = 9 of 14, 64.3%; P = .021). Contralateral single support time bias was greatest in severe TG (35.7% versus 50.0 versus 90.0%; P = .027). Asymmetric toe-off, impact, and support times were observed in all groups. CONCLUSIONS: Traditional understanding of TG is that truncal shift occurs to the ipsilateral side. Using sensor-based measurements, the present study demonstrates a shift of the weight-bearing axis toward the contralateral side with increasing TG severity, which has not been previously described. Inertial sensors are feasible, quantitative gait measuring tools, and may reveal subtle patterns not readily discernible by traditional methods.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kim BI, Wixted CM, Wu CJ, et al. Inertial Sensor Gait Analysis of Trendelenburg Gait in Patients Who Have Hip Osteoarthritis. J Arthroplasty. 2024. PMID: 38280616. doi:10.1016/j.arth.2024.01.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。