文献速递关节外科

锆作为松动骨水泥型膝关节假体的有前景滑液生物标志物

Zirconium as a Promising Synovial Biomarker for Loose Cemented Knee Prosthesis.
PubMed 文献 · J Arthroplasty · 2024-01-18

研究纳入31例因骨水泥型膝关节假体翻修患者,术中取滑液用电感耦合等离子体质谱测锆浓度,按翻修所需力度分为「松动」与「固定良好」。松动组锆浓度均值170.9 μg/L显著高于固定良好组0.6 μg/L(P < .001),受试者工作特征分析得出0.25 μg/L为最佳截断值,灵敏度0.84、特异度0.92、阳性预测值0.94、阴性预测值0.79,诊断性能与X线片无显著差异(P = .66)。作者结论认为锆是诊断含锆骨水泥固定膝关节假体无菌性松动的可靠新型滑液生物标志物,但不应孤立解读,需结合现有诊断工具。

要点

  • 松动组滑液锆浓度均值170.9 μg/L显著高于固定良好组0.6 μg/L(P < .001)。
  • 0.25 μg/L为最佳截断值,灵敏度0.84、特异度0.92、阳性预测值0.94、阴性预测值0.79。
  • 滑液锆诊断性能与X线片无显著差异(P = .66),作者认为不应孤立解读。

核心结论

  • 锆被证明是诊断含锆骨水泥固定膝关节假体无菌性松动的可靠新型滑液生物标志物。
  • 该生物标志物不应孤立解读,而应与现有诊断工具结合使用。

研究设计与样本

  • 研究纳入31例计划行骨水泥型膝关节假体翻修的患者,所有患者初始使用的骨水泥均含锆。
  • 切开关节囊后取滑液标本,用电感耦合等离子体质谱法测定锆水平。
  • 根据取出假体所需力度将假体分级为「松动」或「固定良好」。
  • 术前X线片由2名独立医师评估。

主要发现

  • 滑液中锆浓度在「松动」假体(均值170.9 μg/L,范围0至1941 μg/L)与「固定良好」假体(均值0.6 μg/L,范围0至6 μg/L)之间差异显著(P < .001)。
  • 受试者工作特征分析显示0.25 μg/L为最佳截断值,灵敏度0.84、特异度0.92、阳性预测值0.94、阴性预测值0.79。
  • 与X线片相比,诊断性能无显著差异(P = .66)。

关键数值与推荐

  • 滑液锆浓度最佳截断值为0.25 μg/L,灵敏度0.84、特异度0.92、阳性预测值0.94、阴性预测值0.79。
  • 「松动」假体滑液锆浓度均值170.9 μg/L(范围0至1941 μg/L),「固定良好」假体均值0.6 μg/L(范围0至6 μg/L),组间差异P < .001。

临床怎么用

  • 作者结论认为锆是诊断含锆骨水泥固定膝关节假体无菌性松动的可靠新型滑液生物标志物。
  • 作者指出该生物标志物不应孤立解读,而应与现有诊断工具结合使用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Aseptic loosening is the most common mode of failure after total knee arthroplasty. Despite this, the diagnosis often remains challenging and mainly relies on imaging modalities. Until today, no biomarker exists to aid in diagnosing loosening of the implants. As zirconium (Zr) is often found in bone cement, where it serves as radiopacifier, this study aimed to establish Zr as a synovial biomarker for loosened cemented knee prostheses. METHODS: A total of 31 patients scheduled for revision of a cemented knee prostheses were included. In all patients, the initial used cement contained Zr. After arthrotomy, specimens of synovial fluid were taken and levels of Zr were measured by inductively coupled plasma mass spectrometry. Depending on the necessary amount of force for explantation, the implants were graded "loose" or "well-fixed". Preoperative radiographs were evaluated by 2 independent physicians. RESULTS: The concentration of Zr in the synovial fluid differed significantly (P < .001) between the "loose" (mean 170.9 μg/L, range 0 to 1941 μg/L) and the "well-fixed" (mean 0.6 μg/L, range 0 to 6 μg/L) implants. The receiver operating characteristic analysis revealed 0.25 μg/l as an optimal cutoff value leading to a sensitivity of 0.84, a specificity of 0.92, a positive predictive value of 0.94, and a negative predictive value of 0.79. There was no significant difference in the diagnostic performance compared to radiographs (P = .66). CONCLUSIONS: Zirconium proved to be a reliable novel synovial biomarker for diagnosing aseptic loosening of knee prothesis fixed with cement containing Zr. This biomarker should not be interpreted in isolation, but in combination with existing diagnostic tools.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Anderson PM, Heinz T, Weißenberger M, et al. Zirconium as a Promising Synovial Biomarker for Loose Cemented Knee Prosthesis. J Arthroplasty. 2024. PMID: 38244639. doi:10.1016/j.arth.2024.01.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。